These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 12201424)

  • 1. Interinstitutional variations of sensitometric curves of radiographic dosimetric films.
    Bos LJ; Danciu C; Cheng CW; Brugmans MJ; van der Horst A; Minken A; Mijnheer BJ
    Med Phys; 2002 Aug; 29(8):1772-80. PubMed ID: 12201424
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Normalized sensitometric curves for the verification of hybrid IMRT treatment plans with multiple energies.
    Georg D; Kroupa B; Winkler P; Pötter R
    Med Phys; 2003 Jun; 30(6):1142-50. PubMed ID: 12852539
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Variation of sensitometric curves of radiographic films in high energy photon beams.
    Danciu C; Proimos BS; Rosenwald JC; Mijnheer BJ
    Med Phys; 2001 Jun; 28(6):966-74. PubMed ID: 11439493
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characteristics of sensitometric curves of radiographic films.
    Zhu XR; Yoo S; Jursinic PA; Grimm DF; Lopez F; Rownd JJ; Gillin MT
    Med Phys; 2003 May; 30(5):912-9. PubMed ID: 12773000
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance.
    Fuss M; Sturtewagen E; De Wagter C; Georg D
    Phys Med Biol; 2007 Jul; 52(14):4211-25. PubMed ID: 17664604
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator.
    Zhu XR; Jursinic PA; Grimm DF; Lopez F; Rownd JJ; Gillin MT
    Med Phys; 2002 Aug; 29(8):1687-92. PubMed ID: 12201414
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetric accuracy of Kodak EDR2 film for IMRT verifications.
    Childress NL; Salehpour M; Dong L; Bloch C; White RA; Rosen II
    Med Phys; 2005 Feb; 32(2):539-48. PubMed ID: 15789600
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optimal sensitometric curves of Kodak EDR2 film for dynamic intensity modulated radiation therapy verification.
    Suriyapee S; Pitaxtarnin N; Oonsiri S; Jumpangern C; Israngkul Na Ayuthaya I
    Biomed Imaging Interv J; 2008 Jan; 4(1):e4. PubMed ID: 21614315
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetry of high energy photon and electron beams with CEA films.
    Cheng CW; Das IJ
    Med Phys; 1996 Jul; 23(7):1225-32. PubMed ID: 8839417
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Practical and dosimetric implications of a new type of packaging for radiographic film.
    Gillis S; De Wagter C
    Phys Med Biol; 2005 Apr; 50(8):N63-72. PubMed ID: 15815085
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparative evaluation of Kodak EDR2 and XV2 films for verification of intensity modulated radiation therapy.
    Dogan N; Leybovich LB; Sethi A
    Phys Med Biol; 2002 Nov; 47(22):4121-30. PubMed ID: 12476986
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetry of therapeutic photon beams using an extended dose range film.
    Esthappan J; Mutic S; Harms WB; Dempsey JF; Low DA
    Med Phys; 2002 Oct; 29(10):2438-45. PubMed ID: 12408321
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accurate dosimetry with GafChromic EBT film of a 6 MV photon beam in water: what level is achievable?
    van Battum LJ; Hoffmans D; Piersma H; Heukelom S
    Med Phys; 2008 Feb; 35(2):704-16. PubMed ID: 18383692
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The curvature of sensitometric curves for Kodak XV-2 film irradiated with photon and electron beams.
    van Battum LJ; Huizenga H
    Med Phys; 2006 Jul; 33(7):2396-403. PubMed ID: 16898442
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rapid radiographic film calibration for IMRT verification using automated MLC fields.
    Childress NL; Dong L; Rosen II
    Med Phys; 2002 Oct; 29(10):2384-90. PubMed ID: 12408313
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry.
    Chetty IJ; Charland PM
    Phys Med Biol; 2002 Oct; 47(20):3629-41. PubMed ID: 12433124
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of relative output factors for the 8 and 4 mm collimators of Leksell Gamma Knife Perfexion by film dosimetry.
    Novotny J; Bhatnagar JP; Quader MA; Bednarz G; Lunsford LD; Huq MS
    Med Phys; 2009 May; 36(5):1768-74. PubMed ID: 19544795
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of processor temperature on film dosimetry.
    Srivastava SP; Das IJ
    Med Dosim; 2012; 37(2):138-9. PubMed ID: 21925862
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Film dosimetry in the peripheral region using multiple sensitometric curves.
    Stern RL; Kurylo J; Siantar CH; Lehmann J; Goldberg Z
    Med Phys; 2004 Feb; 31(2):327-32. PubMed ID: 15000618
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of processing time delay on the dose response of Kodak EDR2 film.
    Childress NL; Rosen II
    Med Phys; 2004 Aug; 31(8):2284-8. PubMed ID: 15377095
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.