These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
132 related articles for article (PubMed ID: 12210940)
1. Multiecho segmented EPI with z-shimmed background gradient compensation (MESBAC) pulse sequence for fMRI. Li Z; Wu G; Zhao X; Luo F; Li SJ Magn Reson Med; 2002 Aug; 48(2):312-21. PubMed ID: 12210940 [TBL] [Abstract][Full Text] [Related]
2. BOLD sensitivity and SNR characteristics of parallel imaging-accelerated single-shot multi-echo EPI for fMRI. Bhavsar S; Zvyagintsev M; Mathiak K Neuroimage; 2014 Jan; 84():65-75. PubMed ID: 23954488 [TBL] [Abstract][Full Text] [Related]
3. Single-shot interleaved z-shim EPI with optimized compensation for signal losses due to susceptibility-induced field inhomogeneity at 3 T. Gu H; Feng H; Zhan W; Xu S; Silbersweig DA; Stern E; Yang Y Neuroimage; 2002 Nov; 17(3):1358-64. PubMed ID: 12414275 [TBL] [Abstract][Full Text] [Related]
4. Single-shot T(2)* mapping with 3D compensation of local susceptibility gradients in multiple regions. Posse S; Shen Z; Kiselev V; Kemna LJ Neuroimage; 2003 Feb; 18(2):390-400. PubMed ID: 12595192 [TBL] [Abstract][Full Text] [Related]
5. Optimized EPI for fMRI studies of the orbitofrontal cortex: compensation of susceptibility-induced gradients in the readout direction. Weiskopf N; Hutton C; Josephs O; Turner R; Deichmann R MAGMA; 2007 Feb; 20(1):39-49. PubMed ID: 17268781 [TBL] [Abstract][Full Text] [Related]
6. Increased BOLD sensitivity in the orbitofrontal cortex using slice-dependent echo times at 3 T. Domsch S; Linke J; Heiler PM; Kroll A; Flor H; Wessa M; Schad LR Magn Reson Imaging; 2013 Feb; 31(2):201-11. PubMed ID: 22925606 [TBL] [Abstract][Full Text] [Related]
7. Single-shot dual-z-shimmed sensitivity-encoded spiral-in/out imaging for functional MRI with reduced susceptibility artifacts. Truong TK; Song AW Magn Reson Med; 2008 Jan; 59(1):221-7. PubMed ID: 18050341 [TBL] [Abstract][Full Text] [Related]
8. Real-time feedback optimization of z-shim gradient for automatic compensation of susceptibility-induced signal loss in EPI. Tang YW; Huang TY Neuroimage; 2011 Apr; 55(4):1587-92. PubMed ID: 21256230 [TBL] [Abstract][Full Text] [Related]
9. Optimized EPI for fMRI using a slice-dependent template-based gradient compensation method to recover local susceptibility-induced signal loss. Rick J; Speck O; Maier S; Tüscher O; Dössel O; Hennig J; Zaitsev M MAGMA; 2010 Jun; 23(3):165-76. PubMed ID: 20490606 [TBL] [Abstract][Full Text] [Related]
10. Minimizing susceptibility-induced BOLD sensitivity loss in multi-band accelerated fMRI using point spread function mapping and gradient reversal. In MH; Kang D; Jo HJ; Yarach U; Meyer NK; Trzasko JD; Huston J; Bernstein MA; Shu Y Phys Med Biol; 2023 Jan; 68(2):. PubMed ID: 36549001 [No Abstract] [Full Text] [Related]
12. Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scan. Schmithorst VJ; Dardzinski BJ; Holland SK IEEE Trans Med Imaging; 2001 Jun; 20(6):535-9. PubMed ID: 11437113 [TBL] [Abstract][Full Text] [Related]
13. Simultaneous perfusion and blood-oxygenation-level-dependent measurements using single-shot interleaved z-shim echo-planar imaging. Yang Y; Gu H; Silbersweig DA; Stern E Magn Reson Med; 2005 May; 53(5):1207-11. PubMed ID: 15844153 [TBL] [Abstract][Full Text] [Related]
14. Improved temporal resolution for functional studies with reduced number of segments with three-dimensional echo planar imaging. Narsude M; van der Zwaag W; Kober T; Gruetter R; Marques JP Magn Reson Med; 2014 Sep; 72(3):786-92. PubMed ID: 24136782 [TBL] [Abstract][Full Text] [Related]
16. Optimal EPI parameters for reduction of susceptibility-induced BOLD sensitivity losses: a whole-brain analysis at 3 T and 1.5 T. Weiskopf N; Hutton C; Josephs O; Deichmann R Neuroimage; 2006 Nov; 33(2):493-504. PubMed ID: 16959495 [TBL] [Abstract][Full Text] [Related]
17. Dual echo EPI--the method of choice for fMRI in the presence of magnetic field inhomogeneities? Schwarzbauer C; Mildner T; Heinke W; Brett M; Deichmann R Neuroimage; 2010 Jan; 49(1):316-26. PubMed ID: 19699805 [TBL] [Abstract][Full Text] [Related]
18. An equal-TE ultrafast 3D gradient-echo imaging method with high tolerance to magnetic susceptibility artifacts: Application to BOLD functional MRI. Ryu JK; Jung WB; Yu J; Son JP; Lee SK; Kim SG; Park JY Magn Reson Med; 2021 Apr; 85(4):1986-2000. PubMed ID: 33107102 [TBL] [Abstract][Full Text] [Related]
19. Ultra-high spatial resolution BOLD fMRI in humans using combined segmented-accelerated VFA-FLEET with a recursive RF pulse design. Berman AJL; Grissom WA; Witzel T; Nasr S; Park DJ; Setsompop K; Polimeni JR Magn Reson Med; 2021 Jan; 85(1):120-139. PubMed ID: 32705723 [TBL] [Abstract][Full Text] [Related]
20. Simultaneous acquisition of gradient-echo and asymmetric spin-echo for single-shot z-shim: Z-SAGA. Heberlein KA; Hu X Magn Reson Med; 2004 Jan; 51(1):212-6. PubMed ID: 14705064 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]