BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

212 related articles for article (PubMed ID: 12236529)

  • 1. Gradient elution in normal-phase high-performance liquid chromatographic systems.
    Jandera P
    J Chromatogr A; 2002 Aug; 965(1-2):239-61. PubMed ID: 12236529
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Description and prediction of retention in normal-phase high-performance liquid chromatography with binary and ternary mobile phase.
    Jandera P; Kucerová M; Holíková J
    J Chromatogr A; 1997 Feb; 762(1-2):15-26. PubMed ID: 9098961
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Fast optimization of stepwise gradient conditions for ternary mobile phase in reversed-phase high performance liquid chromatography].
    Shan YC; Zhang YK; Zhao RH
    Se Pu; 2002 Jul; 20(4):289-94. PubMed ID: 12541907
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Gradient elution in aqueous normal-phase liquid chromatography on hydrosilated silica-based stationary phases.
    Soukup J; Janás P; Jandera P
    J Chromatogr A; 2013 Apr; 1286():111-8. PubMed ID: 23497850
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Retention process in reversed phase TLC systems with polar bonded stationary phases.
    Zapała W; Waksmundzka-Hajnos M
    J Sep Sci; 2005 Apr; 28(6):566-74. PubMed ID: 15881087
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Prediction of elution bandwidth for purine compounds by a retention model in reversed-phase HPLC with linear-gradient elution.
    Jin CH; Lee JW; Row KH
    J Sep Sci; 2008 Jan; 31(1):23-9. PubMed ID: 18064619
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Synthesis of a mixed-model stationary phase derived from glutamine for HPLC separation of structurally different biologically active compounds: HILIC and reversed-phase applications.
    Aral T; Aral H; Ziyadanoğulları B; Ziyadanoğulları R
    Talanta; 2015 Jan; 131():64-73. PubMed ID: 25281074
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of linear and cyclic oligomers in polyamide-6 without sample preparation by liquid chromatography using the sandwich injection method. III. Separation mechanism and gradient optimization.
    Mengerink Y; Peters R; van der Wal S; Claessens HA; Cramers CA
    J Chromatogr A; 2002 Mar; 949(1-2):307-26. PubMed ID: 11999748
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Method for characterization of selectivity in reversed-phase liquid chromatography. III. Retention behaviour in gradient-elution chromatography: application to the chromatography of pesticide compounds.
    Jandera P; Spacek M
    J Chromatogr; 1986 Sep; 366():107-26. PubMed ID: 3782316
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental design and re-parameterization of the Neue-Kuss model for accurate and precise prediction of isocratic retention factors from gradient measurements in reversed phase liquid chromatography.
    Rutan SC; Cash K; Stoll DR
    J Chromatogr A; 2023 Nov; 1711():464443. PubMed ID: 37890376
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Secondary isotope effects in liquid chromatography behaviour of 2H and 3H labelled solutes and solvents.
    Valleix A; Carrat S; Caussignac C; Léonce E; Tchapla A
    J Chromatogr A; 2006 May; 1116(1-2):109-26. PubMed ID: 16631181
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Capillary electrochromatography with gradient elution.
    Huber CG; Choudhary G; Horváth C
    Anal Chem; 1997 Nov; 69(21):4429-36. PubMed ID: 9360495
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stationary-phase effects in gradient high-performance liquid chromatography.
    Jandera P; Halama M; Novotná K
    J Chromatogr A; 2004 Mar; 1030(1-2):33-41. PubMed ID: 15043251
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Deformation of gradient shape as a result of preferential adsorption of solvents in mixed mobile phases.
    Piatkowski W; Kramarz R; Poplewska I; Antos D
    J Chromatogr A; 2006 Sep; 1127(1-2):187-99. PubMed ID: 16814799
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Multimode gradient elution in reversed-phase liquid chromatography: application to retention prediction and separation optimization of a set of amino acids in gradient runs involving simultaneous variations of mobile-phase composition, flow rate, and temperature.
    Pappa-Louisi A; Nikitas P; Papachristos K; Balkatzopoulou P
    Anal Chem; 2009 Feb; 81(3):1217-23. PubMed ID: 19123773
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Peak dispersion in gradient elution: An insight based on the plate model.
    Baeza-Baeza JJ; García-Alvarez-Coque MC
    J Chromatogr A; 2020 Feb; 1613():460670. PubMed ID: 31732158
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Study of the column efficiency using gradient elution based on Van Deemter plots.
    Alvarez-Segura T; Cabo-Calvet E; Baeza-Baeza JJ; García-Alvarez-Coque MC
    J Chromatogr A; 2019 Jan; 1584():126-134. PubMed ID: 30497827
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Retention prediction of highly polar ionizable solutes under gradient conditions on a mixed-mode reversed-phase and weak anion-exchange stationary phase.
    Balkatzopoulou P; Fasoula S; Gika H; Nikitas P; Pappa-Louisi A
    J Chromatogr A; 2015 May; 1396():72-6. PubMed ID: 25900744
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fast gradient elution reversed-phase high-performance liquid chromatography with diode-array detection as a high-throughput screening method for drugs of abuse. I. Chromatographic conditions.
    Stoll DR; Paek C; Carr PW
    J Chromatogr A; 2006 Dec; 1137(2):153-62. PubMed ID: 17078962
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simulation of elution profiles in liquid chromatography-I: Gradient elution conditions, and with mismatched injection and mobile phase solvents.
    Jeong LN; Sajulga R; Forte SG; Stoll DR; Rutan SC
    J Chromatogr A; 2016 Jul; 1457():41-9. PubMed ID: 27345210
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.