These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
131 related articles for article (PubMed ID: 12238845)
1. Clinical performance and biocompatibility of poly(2-methoxyethylacrylate)-coated extracorporeal circuits. Gunaydin S; Farsak B; Kocakulak M; Sari T; Yorgancioglu C; Zorlutuna Y Ann Thorac Surg; 2002 Sep; 74(3):819-24. PubMed ID: 12238845 [TBL] [Abstract][Full Text] [Related]
2. Clinical performance and biocompatibility of novel hyaluronan-based heparin-bonded extracorporeal circuits. Gunaydin S; Mccusker K; Vijay V J Extra Corpor Technol; 2005 Sep; 37(3):290-5. PubMed ID: 16350383 [TBL] [Abstract][Full Text] [Related]
3. Biocompatibility of heparin-coated cardiopulmonary bypass circuits in coronary patients with left ventricular dysfunction is superior to PMEA-coated circuits. Kutay V; Noyan T; Ozcan S; Melek Y; Ekim H; Yakut C J Card Surg; 2006; 21(6):572-7. PubMed ID: 17073955 [TBL] [Abstract][Full Text] [Related]
4. Comparison of polymethoxyethylacrylate-coated circuits with leukocyte filtration and reduced heparinization protocol on heparin-bonded circuits in different risk cohorts. Gunaydin S; McCusker K; Vijay V; Isbir S; Sari T; Onur MA; Gurpinar A; Sezgin A; Sargon MF; Tezcaner T; Zorlutuna Y Perfusion; 2006 Nov; 21(6):329-42. PubMed ID: 17312857 [TBL] [Abstract][Full Text] [Related]
5. Clinical and biomaterial evaluation of a new condensed dual-function extracorporeal circuit in reoperation for coronary artery bypass surgery. Gunaydin S; McCusker K; Vijay V Int J Artif Organs; 2009 Nov; 32(11):802-10. PubMed ID: 20020412 [TBL] [Abstract][Full Text] [Related]
6. In vivo comparison study of FDA-approved surface-modifying additives and poly-2-methoxyethylacrylate circuit surfaces coatings during cardiopulmonary bypass. Ask A; Holt D; Smith L J Extra Corpor Technol; 2006 Mar; 38(1):27-32. PubMed ID: 16637520 [TBL] [Abstract][Full Text] [Related]
7. Hemocompatibility of PMEA coated oxygenators used for extracorporeal circulation procedures. Zimmermann AK; Aebert H; Reiz A; Freitag M; Husseini M; Ziemer G; Wendel HP ASAIO J; 2004; 50(3):193-9. PubMed ID: 15171468 [TBL] [Abstract][Full Text] [Related]
8. Effect of poly (2-methoxyethyl acrylate)-coated oxygenators on haemolysis. Kocakulak M; Ozgürtaş T; Ayhan H J Biomater Sci Polym Ed; 2006; 17(4):449-60. PubMed ID: 16768295 [TBL] [Abstract][Full Text] [Related]
9. Clinical and biomaterial evaluation of hyaluronan-based heparin-bonded extracorporeal circuits with reduced versus full systemic anticoagulation in reoperation for coronary revascularization. Gunaydin S; Farsak B; McCusker K; Vijay V; Sari T; Onur MA; Gurpinar A; Zorlutuna Y J Cardiovasc Med (Hagerstown); 2009 Feb; 10(2):135-42. PubMed ID: 19377380 [TBL] [Abstract][Full Text] [Related]
10. A new poly-2-methoxyethylacrylate-coated cardiopulmonary bypass circuit possesses superior platelet preservation and inflammatory suppression efficacy. Ikuta T; Fujii H; Shibata T; Hattori K; Hirai H; Kumano H; Suehiro S Ann Thorac Surg; 2004 May; 77(5):1678-83. PubMed ID: 15111165 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of biocompatible cardiopulmonary bypass circuit use during pediatric open heart surgery. Deptula J; Glogowski K; Merrigan K; Hanson K; Felix D; Hammel J; Duncan K J Extra Corpor Technol; 2006 Mar; 38(1):22-6. PubMed ID: 16637519 [TBL] [Abstract][Full Text] [Related]
12. Clinical performance and biocompatibility of hyaluronan-based heparin-bonded extracorporeal circuits in different risk cohorts. Gunaydin S; McCusker K; Sari T; Onur MA; Zorlutuna Y Interact Cardiovasc Thorac Surg; 2010 Mar; 10(3):371-6. PubMed ID: 20026488 [TBL] [Abstract][Full Text] [Related]
13. Poly-2-methoxyethylacrylate-coated cardiopulmonary bypass circuit can reduce transfusion of platelet products compared to heparin-coated circuit during aortic arch surgery. Hosoyama K; Ito K; Kawamoto S; Kumagai K; Akiyama M; Adachi O; Kawatsu S; Sasaki K; Suzuki M; Sugawara Y; Shimizu Y; Saiki Y J Artif Organs; 2016 Sep; 19(3):233-40. PubMed ID: 26909493 [TBL] [Abstract][Full Text] [Related]
14. Influence of PMEA-coated bypass circuits on perioperative inflammatory response. Ninomiya M; Miyaji K; Takamoto S Ann Thorac Surg; 2003 Mar; 75(3):913-7; discussion 917-8. PubMed ID: 12645716 [TBL] [Abstract][Full Text] [Related]
15. New surface biopolymers for oxygenators: an in vitro hemocompatibility test of poly(2-methoxyethylacrylate). Baykut D; Bernet F; Wehrle J; Weichelt K; Schwartz P; Zerkowski HR Eur J Med Res; 2001 Jul; 6(7):297-305. PubMed ID: 11485890 [TBL] [Abstract][Full Text] [Related]
16. Clinical evaluation of poly(2-methoxyethylacrylate) in primary coronary artery bypass grafting. Vang SN; Brady CP; Christensen KA; Isler JR; Allen KR J Extra Corpor Technol; 2005 Mar; 37(1):23-31. PubMed ID: 15804153 [TBL] [Abstract][Full Text] [Related]
17. Effect of polymer coating (poly 2-methoxyethylacrylate) of the oxygenator on hemostatic markers during cardiopulmonary bypass in children. Eisses MJ; Geiduschek JM; Jonmarker C; Cohen GA; Chandler WL J Cardiothorac Vasc Anesth; 2007 Feb; 21(1):28-34. PubMed ID: 17289476 [TBL] [Abstract][Full Text] [Related]