These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 1225074)

  • 1. [Bloodless and continuous oxygen monitoring using a transcutaneous oxygen electrode].
    Schwickardi D
    Anasthesiol Intensivmed Prax; 1975 Oct; 11(1):63-6. PubMed ID: 1225074
    [No Abstract]   [Full Text] [Related]  

  • 2. Oxygen tension monitoring with cutaneous electrodes in adults.
    Scacci R; McMahon JL; Miller WF
    Med Instrum; 1976; 10(4):192-4. PubMed ID: 958046
    [No Abstract]   [Full Text] [Related]  

  • 3. The influence of different electrode temperatures on the recorded transcutaneous Po2 level.
    Löfgren O; Jacobson L
    Pediatrics; 1979 Dec; 64(6):892-7. PubMed ID: 514717
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The monitoring of adult intensive care patients by transcutaneous PO2 measurements.
    Strasser K; Goeckenjan G
    Birth Defects Orig Artic Ser; 1979; 15(4):525-30. PubMed ID: 534736
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transcutaneous PO2 as a trend indicator of arterial PO2 in normal anesthesized adults.
    Rafferty TD; Marrero O; Nardi D; Schachter EN; Mentelos R; Ngeow YF
    Anesth Analg; 1982 Mar; 61(3):252-5. PubMed ID: 7199839
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correlation of hemodynamic variables with transcutaneous PO2 measurements in critically ill adult patients.
    Reed RL; Maier RV; Landicho D; Kenny MA; Carrico CJ
    J Trauma; 1985 Nov; 25(11):1045-53. PubMed ID: 4057292
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Transcutaneous measurement of pO2.(author's transl)].
    Dautzenberg B; Carter H; Sors C
    Rev Fr Mal Respir; 1981; 9(4):327-35. PubMed ID: 7302351
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [In vivo time lag and response time of transcutaneous oxygen monitoring].
    Andoh T; Usuda Y; Sumitomo M; Yamada M; Numata K
    Masui; 1985 May; 34(5):595-8. PubMed ID: 4032688
    [No Abstract]   [Full Text] [Related]  

  • 9. Continuous monitoring of arterial oxygen partial pressure. Discussion.
    Biotelem Patient Monit; 1979; 6(1-2):75-90. PubMed ID: 486728
    [No Abstract]   [Full Text] [Related]  

  • 10. A new tcPO2 electrode and its application to adults.
    Hagihara B; Fukai T; Hachino Y; Nakayama K; Ishibashi F; Ohta A; Ohminato S; Takemura H; Hasegawa T; Kurachi K; Okada Y; Sugimoto T; Nomura K; Yoshida K
    Birth Defects Orig Artic Ser; 1979; 15(4):75-90. PubMed ID: 534749
    [No Abstract]   [Full Text] [Related]  

  • 11. Continuous transcutaneous measurement of partial pressure of oxygen in acute myocardial infarction.
    Löllgen H; Kersting F; Meinertz T; Kasper W; Just H
    Birth Defects Orig Artic Ser; 1979; 15(4):523. PubMed ID: 534735
    [No Abstract]   [Full Text] [Related]  

  • 12. [Transcutaneous Po2 monitoring in exercise test].
    Yamamoto M; Kurihara N; Shirai S; Hirata K; Hikiishi F; Terakawa K; Ohta K; Fujimoto S; Seko K
    Rinsho Byori; 1983 Feb; 31(2):205-9. PubMed ID: 6855000
    [No Abstract]   [Full Text] [Related]  

  • 13. Effect of electrode temperature and in vivo calibration on accuracy of transcutaneous estimation of arterial oxygen tension in infants.
    Pollitzer MJ; Whitehead MD; Reynolds EO; Delpy D
    Pediatrics; 1980 Mar; 65(3):515-22. PubMed ID: 7360538
    [No Abstract]   [Full Text] [Related]  

  • 14. Clinical experience using the Hagihara electrode tcPO2 monitor.
    Takemura H; Ohminato S; Hasegawa T; Kurachi K; Hagihara B; Hachino Y; Nakayama K; Yoshida K; Fukai T; Nomura K
    Birth Defects Orig Artic Ser; 1979; 15(4):377-81. PubMed ID: 534721
    [No Abstract]   [Full Text] [Related]  

  • 15. Skin craters--a complication of transcutaneous oxygen monitoring.
    Golden SM
    Pediatrics; 1981 Apr; 67(4):514-6. PubMed ID: 7254973
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transcutaneous oxygen measurements: calibration analysis and electrode stabilization methods.
    Severinghaus JW; Peabody JL; Thunström AM; Stafford M
    Acta Anaesthesiol Scand Suppl; 1978; 70():180-2. PubMed ID: 283662
    [No Abstract]   [Full Text] [Related]  

  • 17. [Clinical application of transcutaneous PO2 and PCO2 measurements].
    Sun ZL
    Zhonghua Jie He He Hu Xi Xi Ji Bing Za Zhi; 1985 Oct; 8(5):274-6, 319. PubMed ID: 3938966
    [No Abstract]   [Full Text] [Related]  

  • 18. [An improvement of per-operative monitoring. Telectronics's electrode plate].
    Radiguet de la Bastaie P
    Cah Anesthesiol; 1972 Apr; 20(3):279-82. PubMed ID: 5078489
    [No Abstract]   [Full Text] [Related]  

  • 19. [Transcutaneous monitoring of arterial PO2 during anaesthesia. Usefulness of the method exemplified on short anaesthetics (author's transl)].
    Huch R; Huch A
    Anaesthesist; 1974 Apr; 23(4):181-5. PubMed ID: 4460741
    [No Abstract]   [Full Text] [Related]  

  • 20. Letter: Is transcutaneous Po2 reliable for arterial oxygen monitoring in newborn infants?
    Duc G; Bucher HU; Micheli JL; Johanson BA
    Pediatrics; 1975 Apr; 55(4):566-7. PubMed ID: 1128970
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.