These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 12270887)

  • 1. Determination and interpretation of total and transversal linear efficiencies in push-pull ventilation systems for open surface tanks.
    Marzal F; Gonzalez E; Minana A; Baeza A
    Ann Occup Hyg; 2002 Oct; 46(7):629-35. PubMed ID: 12270887
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of push element geometry on the capture efficiency of push-pull ventilation systems in surface treatment tanks.
    Marzal F; Gonzalez E; Minana A; Baeza A
    Ann Occup Hyg; 2002 Jun; 46(4):383-93. PubMed ID: 12176707
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design guidelines for push-pull ventilation systems through computational fluid dynamics modeling.
    Rota R; Nano G; Canossa L
    AIHAJ; 2001; 62(2):141-8. PubMed ID: 11331985
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Numerical investigation and recommendations for push-pull ventilation systems.
    Chern MJ; Ma CH
    J Occup Environ Hyg; 2007 Mar; 4(3):184-97. PubMed ID: 17237024
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of a push-pull ventilation system to control solder fume.
    Watson SI; Cain JR; Cowie H; Cherrie JW
    Ann Occup Hyg; 2001 Nov; 45(8):669-76. PubMed ID: 11718662
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Aerodynamic characteristics and design guidelines of push-pull ventilation systems.
    Huang RF; Lin SY; Jan SY; Hsieh RH; Chen YK; Chen CW; Yeh WY; Chang CP; Shih TS; Chen CC
    Ann Occup Hyg; 2005 Jan; 49(1):1-15. PubMed ID: 15591077
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Methodologies for determining capture efficiencies in surface treatment tanks.
    Marzal F; González E; Miñana A; Baeza A
    AIHA J (Fairfax, Va); 2003; 64(5):604-8. PubMed ID: 14521434
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Visualization of airflows in push-pull ventilation systems applied to surface treatment tanks.
    Marzal F; González E; Miñana A; Baeza A
    AIHA J (Fairfax, Va); 2003; 64(4):455-60. PubMed ID: 12908859
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Numerical investigation of turbulent diffusion in push-pull and exhaust fume cupboards.
    Chern MJ; Cheng WY
    Ann Occup Hyg; 2007 Aug; 51(6):517-31. PubMed ID: 17638713
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Evaluation of the reverse flow around a worker's body produced by a local exhaust hood].
    Ojima J
    Sangyo Eiseigaku Zasshi; 2003 Jul; 45(4):125-32. PubMed ID: 12968498
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analytical model for evaluating lateral capture efficiencies in surface treatment tanks.
    Marzal F; González E; Miñana A; Baeza A
    AIHA J (Fairfax, Va); 2002; 63(5):572-7. PubMed ID: 12529911
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improved local exhaust control by directed push-pull ventilation system.
    Hampl V; Hughes RT
    Am Ind Hyg Assoc J; 1986 Jan; 47(1):59-65. PubMed ID: 3946201
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Some engineering countermeasures to reduce exposure to welding fumes and gases avoiding occurrence of blow holes in welded material.
    Iwasaki T; Fujishiro Y; Kubota Y; Ojima J; Shibata N
    Ind Health; 2005 Apr; 43(2):351-7. PubMed ID: 15895853
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Flow and containment characteristics of a sash-less, variable-height inclined air-curtain fume hood.
    Huang RF; Chen JK; Hung WL
    Ann Occup Hyg; 2013 Aug; 57(7):934-52. PubMed ID: 23519947
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Research on a push-pull industrial trough-side exhaust hood based on CFD simulation and experiment.
    Song Y; Chen X; Zhang Z; Cao S; Du T; Guo H
    Sci Total Environ; 2022 Jun; 827():154265. PubMed ID: 35259371
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of push-pull ventilation.
    Huebener DJ; Hughes RT
    Am Ind Hyg Assoc J; 1985 May; 46(5):262-7. PubMed ID: 4003278
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Changing Patterns of the Flow Ratio with the Distance of Exhaust and Supply Hood in a Parallel Square Push-Pull Ventilation.
    Chen J
    Int J Environ Res Public Health; 2022 Mar; 19(5):. PubMed ID: 35270650
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Flow and leakage characteristics of a sashless inclined air-curtain (sIAC) fume hood containing tall pollutant-generation tanks.
    Chen JK; Huang RF; Hung WL
    J Occup Environ Hyg; 2013; 10(12):694-704. PubMed ID: 24195536
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development and evaluation of a new push-pull ventilation system for sheet-adhesive work inside bus-body.
    Yotsumoto H; Hayakawa Y; Myojo T
    Ind Health; 2003 Jan; 41(1):24-31. PubMed ID: 12674550
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Local ventilation solution for large, warm emission sources.
    Kulmala I; Hynynen P; Welling I; Säämänen A
    Ann Occup Hyg; 2007 Jan; 51(1):35-43. PubMed ID: 16861238
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.