These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

97 related articles for article (PubMed ID: 12351201)

  • 21. Concentration of extracellular L-glutamate released from cultured nerve cells measured with a small-volume online sensor.
    Niwa O; Torimitsu K; Morita M; Osborne P; Yamamoto K
    Anal Chem; 1996 Jun; 68(11):1865-70. PubMed ID: 8686911
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Isolation and functional characterization of an allatotropin receptor from Manduca sexta.
    Horodyski FM; Verlinden H; Filkin N; Vandersmissen HP; Fleury C; Reynolds SE; Kai ZP; Broeck JV
    Insect Biochem Mol Biol; 2011 Oct; 41(10):804-14. PubMed ID: 21699978
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Fiber-optic ammonia sensor for measuring synaptic glutamate and extracellular ammonia.
    Kar S; Arnold MA
    Anal Chem; 1992 Oct; 64(20):2438-43. PubMed ID: 1361308
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Optical glutamate sensor for spatiotemporal analysis of synaptic transmission.
    Namiki S; Sakamoto H; Iinuma S; Iino M; Hirose K
    Eur J Neurosci; 2007 Apr; 25(8):2249-59. PubMed ID: 17445223
    [TBL] [Abstract][Full Text] [Related]  

  • 25. High throughput analysis of endogenous glutamate release using a fluorescence plate reader.
    Sim AT; Herd L; Proctor DT; Baldwin ML; Meunier FA; Rostas JA
    J Neurosci Methods; 2006 May; 153(1):43-7. PubMed ID: 16293315
    [TBL] [Abstract][Full Text] [Related]  

  • 26. High-speed imaging of glutamate release with genetically encoded sensors.
    Dürst CD; Wiegert JS; Helassa N; Kerruth S; Coates C; Schulze C; Geeves MA; Török K; Oertner TG
    Nat Protoc; 2019 May; 14(5):1401-1424. PubMed ID: 30988508
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Nano-molar level hydrogen peroxide detection by horseradish peroxidase adsorbed cup-stacked carbon nanotube electrodes and applications to L-glutamate detection.
    Noda T; Ukai T; Yao T
    Anal Sci; 2010; 26(6):675-9. PubMed ID: 20543499
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Development of biosensor based on immobilized L-glutamate oxidase for determination of monosodium glutamate in food.
    Basu AK; Chattopadhyay P; Roychudhuri U; Chakraborty R
    Indian J Exp Biol; 2006 May; 44(5):392-8. PubMed ID: 16708893
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Miniaturized thin film glutamate and glutamine biosensors.
    Moser I; Jobst G; Aschauer E; Svasek P; Varahram M; Urban G; Zanin VA; Tjoutrina GY; Zharikova AV; Berezov TT
    Biosens Bioelectron; 1995; 10(6-7):527-32. PubMed ID: 7612205
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Identification of neuropeptides from brains of larval Manduca sexta and Lacanobia oleracea using MALDI-TOF mass spectrometry and post-source decay.
    Audsley N; Weaver RJ
    Peptides; 2003 Oct; 24(10):1465-74. PubMed ID: 14706525
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Glutamate regulation of non-quantal release of acetylcholine in the rat neuromuscular junction.
    Malomouzh AI; Mukhtarov MR; Nikolsky EE; Vyskocil F; Lieberman EM; Urazaev AK
    J Neurochem; 2003 Apr; 85(1):206-13. PubMed ID: 12641742
    [TBL] [Abstract][Full Text] [Related]  

  • 32. On-line microdialysis system with poly(amidoamine)-encapsulated Pt nanoparticles biosensor for glutamate sensing in vivo.
    Yu Y; Sun Q; Zhou T; Zhu M; Jin L; Shi G
    Bioelectrochemistry; 2011 Apr; 81(1):53-7. PubMed ID: 21277265
    [TBL] [Abstract][Full Text] [Related]  

  • 33. 24S-Hydroxycholesterol enhances synaptic vesicle cycling in the mouse neuromuscular junction: Implication of glutamate NMDA receptors and nitric oxide.
    Kasimov MR; Fatkhrakhmanova MR; Mukhutdinova KA; Petrov AM
    Neuropharmacology; 2017 May; 117():61-73. PubMed ID: 28153530
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The discovery of a novel antagonist - Manduca sexta allatotropin analogue - as an insect midgut active ion transport inhibitor.
    Deng XL; Kai ZP; Chamberlin ME; Horodyski FM; Yang XL
    Pest Manag Sci; 2016 Nov; 72(11):2176-2180. PubMed ID: 26853385
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Nitric oxide dependence of glutamate-mediated modulation at a vertebrate neuromuscular junction.
    Pinard A; Robitaille R
    Eur J Neurosci; 2008 Aug; 28(3):577-87. PubMed ID: 18702729
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Improving the reproducibility of hydrogel-coated glutamate microsensors by using an automated dipcoater.
    Oldenziel WH; Beukema W; Westerink BH
    J Neurosci Methods; 2004 Dec; 140(1-2):117-26. PubMed ID: 15589341
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Continuous measurement of glutamate and hydrogen peroxide using a microfabricated biosensor for studying the neurotoxicity of tributyltin.
    Kurita R; Hayashi K; Torimitsu K; Niwa O
    Anal Sci; 2003 Dec; 19(12):1581-5. PubMed ID: 14696918
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Monitoring of glucose and glutamate using enzyme microstructures and scanning electrochemical microscopy.
    Mureşan L; Nistor M; Gáspár S; Popescu IC; Csöregi E
    Bioelectrochemistry; 2009 Sep; 76(1-2):81-6. PubMed ID: 19520620
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Graphene and tricobalt tetraoxide nanoparticles based biosensor for electrochemical glutamate sensing.
    Dalkıran B; Erden PE; Kılıç E
    Artif Cells Nanomed Biotechnol; 2017 Mar; 45(2):340-348. PubMed ID: 26939621
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [C3(OH)2mim][BF4]-Au/Pt biosensor for glutamate sensing in vivo integrated with on-line microdialysis system.
    Yu Y; Liu X; Jiang D; Sun Q; Zhou T; Zhu M; Jin L; Shi G
    Biosens Bioelectron; 2011 Mar; 26(7):3227-32. PubMed ID: 21239160
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.