These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 1235313)

  • 1. A simplified method for measuring helium closing volume.
    McClelland K; Mittman C
    Chest; 1975 Jan; 67(1):110-11. PubMed ID: 1235313
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The measurement of "closing volume" as affected by lung volume at tracer bolus inspiration, breath holding, and expiratory flow rate.
    Susskind H; Richards P; Atkins HL
    Scand J Respir Dis Suppl; 1974; 85():218-27. PubMed ID: 4534911
    [No Abstract]   [Full Text] [Related]  

  • 3. Lung volume in mechanically ventilated patients: measurement by simplified helium dilution compared to quantitative CT scan.
    Patroniti N; Bellani G; Manfio A; Maggioni E; Giuffrida A; Foti G; Pesenti A
    Intensive Care Med; 2004 Feb; 30(2):282-289. PubMed ID: 14714108
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A modified helium dilution technique for measuring small lung gas volumes.
    Roy CH; Barnes RJ; Heath MF; Sensky PL
    J Dev Physiol; 1992 Feb; 17(2):87-92. PubMed ID: 1500637
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multiple breath helium dilution measurement of lung volumes in adults.
    Brown R; Leith DE; Enright PL
    Eur Respir J; 1998 Jan; 11(1):246-55. PubMed ID: 9543301
    [No Abstract]   [Full Text] [Related]  

  • 6. [Errors in the lung volume measurement and its reproducibility by the method of helium displacement in the closed system].
    Kanaev NN; Klement RF; Kiriukhin AB
    Med Tekh; 1976; (2):26-8. PubMed ID: 1025425
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Helium closing volumes.
    Green M; Travis DM; Don H
    Scand J Respir Dis Suppl; 1974; 85():201-7. PubMed ID: 4536592
    [No Abstract]   [Full Text] [Related]  

  • 8. Acoustic helium analyzer for closing volume measurement.
    Hamilton LH; Christman NT; Rickaby DA
    J Appl Physiol Respir Environ Exerc Physiol; 1977 Nov; 43(5):911-5. PubMed ID: 591485
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of an acoustic helium analyzer and microprocessor for rapid measurement of absolute lung volume during mechanical ventilation.
    Gillespie DJ
    Crit Care Med; 1985 Feb; 13(2):118-21. PubMed ID: 3967501
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Standardisation of the measurement of lung volumes.
    Wanger J; Clausen JL; Coates A; Pedersen OF; Brusasco V; Burgos F; Casaburi R; Crapo R; Enright P; van der Grinten CP; Gustafsson P; Hankinson J; Jensen R; Johnson D; Macintyre N; McKay R; Miller MR; Navajas D; Pellegrino R; Viegi G
    Eur Respir J; 2005 Sep; 26(3):511-22. PubMed ID: 16135736
    [No Abstract]   [Full Text] [Related]  

  • 11. Single-breath, room-air method for measuring closing volume (phase 4) in the normal human lung.
    Flores XF; Cruz JC
    Chest; 1992 Aug; 102(2):438-43. PubMed ID: 1643929
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of lung volume measurements by single breath helium and multiple breath nitrogen equilibration methods in normal subjects and COPD patients.
    Brugman TM; Morris JF; Temple WP
    Respiration; 1986; 49(1):52-60. PubMed ID: 3513268
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Modifications of pulmonary residual volume measuring method using closed circuit helium dilution technic].
    Nigorikawa T; Muramoto N; Yoshigi H; Oishi K
    Kokyu To Junkan; 1987 Mar; 35(3):299-303. PubMed ID: 3296069
    [No Abstract]   [Full Text] [Related]  

  • 14. [Practicability of a quick helium-mixing procedure for estimation of residual volume by measurement of density (author's transl)].
    Petro W; Gahlen G; Korn V; Smidt U; Nakhosteen JA; Konietzko N
    Prax Klin Pneumol; 1980 Sep; 34(9):541-7. PubMed ID: 7454664
    [No Abstract]   [Full Text] [Related]  

  • 15. Comparison of plethysmographic and helium dilution lung volumes in patients with a giant emphysematous bulla as selection criteria for endobronchial valve implant.
    Fiorelli A; Scaramuzzi R; Pierdiluca M; Frongillo E; Messina G; Serra N; De Felice A; Santini M
    Eur J Cardiothorac Surg; 2017 Sep; 52(3):534-542. PubMed ID: 28444339
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Comparison of measuring closing volume simultaneously by helium and nitrogen method (author's transl)].
    Wang CQ
    Zhonghua Jie He He Hu Xi Xi Ji Bing Za Zhi; 1981 Apr; 4(2):99-101. PubMed ID: 7318605
    [No Abstract]   [Full Text] [Related]  

  • 17. Estimation of lung volumes from chest radiographs using shape information.
    Pierce RJ; Brown DJ; Holmes M; Cumming G; Denison DM
    Thorax; 1979 Dec; 34(6):726-34. PubMed ID: 542910
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Difference between the He bolus and N2 technique for measuring closing volume.
    Stănescu D; Veriter C; Brasseur L
    J Appl Physiol Respir Environ Exerc Physiol; 1977 Jun; 42(6):859-64. PubMed ID: 881387
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of an acoustic helium analyzer for measuring lung volumes.
    Krumpe PE; MacDannald HJ; Finley TN; Schear HE; Hall J; Cribbs D
    J Appl Physiol Respir Environ Exerc Physiol; 1981 Jan; 50(1):203-9. PubMed ID: 7204187
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The closing volume test: evaluation of nitrogen and bolus methods in a random population.
    Knudson RJ; Lebowitz MD; Burton AP; Knudson DE
    Am Rev Respir Dis; 1977 Mar; 115(3):423-34. PubMed ID: 842954
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.