These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
184 related articles for article (PubMed ID: 12362175)
1. Should we be doing endoscope surveillance cultures? Everts R; Holland D N Z Med J; 2002 Jul; 115(1158):U101. PubMed ID: 12362175 [No Abstract] [Full Text] [Related]
2. ESGE-ESGENA guideline for quality assurance in reprocessing: microbiological surveillance testing in endoscopy. Beilenhoff U; Neumann CS; Rey JF; Biering H; Blum R; Schmidt V; Endoscopy; 2007 Feb; 39(2):175-81. PubMed ID: 17327980 [No Abstract] [Full Text] [Related]
3. Reprocessing endoscopes: national recommendations with a special emphasis on cleaning--the German perspective. Heeg P J Hosp Infect; 2004 Apr; 56 Suppl 2():S23-6. PubMed ID: 15110119 [TBL] [Abstract][Full Text] [Related]
5. Are you confident about scope reprocessing? Smith P OR Manager; 2003 May; 19(5):8-9. PubMed ID: 12762163 [No Abstract] [Full Text] [Related]
6. ESGE/ESGENA guideline for process validation and routine testing for reprocessing endoscopes in washer-disinfectors, according to the European Standard prEN ISO 15883 parts 1, 4 and 5. Beilenhoff U; Neumann CS; Biering H; Blum R; Schmidt V; Rey JF; ; Endoscopy; 2007 Jan; 39(1):85-94. PubMed ID: 17252467 [No Abstract] [Full Text] [Related]
7. Reprocessing flexible gastrointestinal endoscopes after a period of disuse: is it necessary? Vergis AS; Thomson D; Pieroni P; Dhalla S Endoscopy; 2007 Aug; 39(8):737-9. PubMed ID: 17661250 [TBL] [Abstract][Full Text] [Related]
13. Endoscope disinfection and its pitfalls--requirement for retrograde surveillance cultures. Buss AJ; Been MH; Borgers RP; Stokroos I; Melchers WJ; Peters FT; Limburg AJ; Degener JE Endoscopy; 2008 Apr; 40(4):327-32. PubMed ID: 18264888 [TBL] [Abstract][Full Text] [Related]
14. [Disinfection and recontamination of rigid endoscopes: improved safety using an immersion quiver system]. Rohrmeier C; Strutz J; Schneider-Brachert W HNO; 2014 Oct; 62(10):746-51. PubMed ID: 24867489 [TBL] [Abstract][Full Text] [Related]
15. Reprocessing endoscopes: United States perspective. Rutala WA; Weber DJ J Hosp Infect; 2004 Apr; 56 Suppl 2():S27-39. PubMed ID: 15110120 [TBL] [Abstract][Full Text] [Related]
16. [Anew preparation of an endoscope with STERIS?]. Daschner F Z Gastroenterol; 1999 Jun; 37(6):XXXI. PubMed ID: 10427664 [No Abstract] [Full Text] [Related]
17. Endo reprocessing lapses at the VA. OR Manager; 2009 Jun; 25(6):19, 21. PubMed ID: 19558019 [No Abstract] [Full Text] [Related]
18. Multisociety guideline on reprocessing flexible GI endoscopes: 2016 update. ; Petersen BT; Cohen J; Hambrick RD; Buttar N; Greenwald DA; Buscaglia JM; Collins J; Eisen G Gastrointest Endosc; 2017 Feb; 85(2):282-294.e1. PubMed ID: 28069113 [No Abstract] [Full Text] [Related]
19. Endoscope surveillance cultures. Dunn J N Z Med J; 2002 Aug; 115(1160):U149. PubMed ID: 12362206 [No Abstract] [Full Text] [Related]
20. Microbiological surveillance of endoscopes and implications for current reprocessing procedures adopted by an Italian teaching hospital. Cottarelli A; De Giusti M; Solimini AG; Venuto G; Palazzo C; Del Cimmuto A; Osborn J; Marinelli L Ann Ig; 2020; 32(2):166-177. PubMed ID: 31944211 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]