BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 12382748)

  • 1. Extremity and whole-body dosemeters for beta and beta gamma fields based on LiF:Mg,Cu,P thin detectors.
    Pérez S; Ginjaume M; Ortega X; Duch MA; Roig M
    Radiat Prot Dosimetry; 2002; 101(1-4):261-6. PubMed ID: 12382748
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields.
    Ginjaume M; Pérez S; Ortega X; Duch MA
    Radiat Prot Dosimetry; 2006; 120(1-4):316-20. PubMed ID: 16644980
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Application of whole-body personal TL dosemeters in mixed field beta-gamma radiation.
    Ciupek K; Aksamit D; Wołoszczuk K
    Radiat Prot Dosimetry; 2014 Nov; 162(1-2):20-3. PubMed ID: 25009188
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of the performance of two LiF:Mg,Ti and LiF:Mg,Cu,P dosemeters for extremity monitoring.
    Freire LC; Pereira MF; Calado AM; Santos LM; Cardoso JV; Alves JG
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):140-3. PubMed ID: 21081520
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Energy response of different types of RADOS personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) TL detectors.
    Obryk B; Hranitzky C; Stadtmann H; Budzanowski M; Olko P
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):211-4. PubMed ID: 21227957
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Individual monitoring in nuclear medicine therapeutic procedures using extremity dosemeters LiF(Mg, Cu, P).
    Sarti G; Del Dottore F; Fabbri C; Tassinari L; Pagan S; Rustignoli M; Motta P
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):521-4. PubMed ID: 21030398
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The right choice: extremity dosemeter for different radiation fields.
    Brasik N; Stadtmann H; Kindl P
    Radiat Prot Dosimetry; 2007; 125(1-4):331-4. PubMed ID: 17711869
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluating two extremity dosemeters based on LiF:Mg,Ti or LiF:Mg,Cu,P.
    Luo LZ; Velbeck KJ; Rotunda JE
    Radiat Prot Dosimetry; 2002; 101(1-4):211-6. PubMed ID: 12382737
    [TBL] [Abstract][Full Text] [Related]  

  • 9. TYPE TESTING OF LiF:Mg,Cu,P (TLD-100H) WHOLE-BODY DOSEMETERS FOR THE ASSESSMENT OF Hp(10) AND Hp(0.07).
    Pereira JS; Pereira MF; Rangel S; Caldeira M; Carvalhal G; Santos LM; Cardoso JV; Alves JG
    Radiat Prot Dosimetry; 2019 Aug; 184(2):216-223. PubMed ID: 30496554
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A system for rapid large-area monitoring of gamma dose rates in the environment based on MCP-N (LiF:Mg,Cu,P) TL detectors.
    Budzanowski M; Olko P; Ryba E; Woźnicka U
    Radiat Prot Dosimetry; 2002; 101(1-4):205-9. PubMed ID: 12382736
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluating the performance of the Harshaw™ DXTRAD LiF:Mg,Cu,P finger ring with two different thickness filters.
    Baker ST; Roberts GH; Gilvin PJ
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):243-5. PubMed ID: 21212080
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Thermoluminescence dosimetric properties of a new thin beta detector (LiF:Mg, Cu, P; GR-200F) in comparison with highly sensitive Al2O3:C beta dosimeters.
    El-Faramawy NA; Göksu HY; Panzer W
    J Radiol Prot; 2004 Sep; 24(3):273-82. PubMed ID: 15511019
    [TBL] [Abstract][Full Text] [Related]  

  • 13. FADING EFFECT OF LiF:Mg,Ti AND LiF:Mg,Cu,P Ext-Rad AND WHOLE-BODY DETECTORS.
    Pereira J; Pereira MF; Rangel S; Saraiva M; Santos LM; Cardoso JV; Alves JG
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):177-80. PubMed ID: 26503857
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pre- and post-irradiation fading effect for LiF:Mg,Ti and LiF:Mg,Cu,P materials used in routine monitoring.
    Carinou E; Askounis P; Dimitropoulou F; Kiranos G; Kyrgiakou H; Nirgianaki E; Papadomarkaki E; Kamenopoulou V
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):207-10. PubMed ID: 21199822
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of background exposure on detection and determination limits for a TL dosimetry system based on LiF:Mg,Cu,P(GR-200A).
    Tang KY; Liu BX; Zhu HY; Wang YC; Shen WX
    Radiat Prot Dosimetry; 2002; 101(1-4):187-90. PubMed ID: 12382732
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Energy response of GR-200A thermoluminescence dosemeters to 60Co and to monoenergetic synchrotron radiation in the energy range 28-40 keV.
    Emiro F; Di Lillo F; Mettivier G; Fedon C; Longo R; Tromba G; Russo P
    Radiat Prot Dosimetry; 2016 Jan; 168(1):40-5. PubMed ID: 25737582
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A high-resolution map of gamma dose rates in Cluj County, Romania using LiF:Mg,Cu,P detectors.
    Dolha M; Timar-Gabor A; Dicu T; Begy R; Anton M; Cosma C
    Radiat Prot Dosimetry; 2014 Nov; 162(1-2):14-9. PubMed ID: 25009186
    [TBL] [Abstract][Full Text] [Related]  

  • 18. UV-induced bleaching of deep traps in Harshaw TLD LiF:Mg,Cu,P and LiF:Mg,Ti.
    Benevides L; Voss S; Nita I; Rotunda J; Velbeck K; Luo LZ; Moscovitch M
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):199-201. PubMed ID: 21310735
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance of different thermoluminescence dosimeters in 90SR+90Y radiation fields.
    Oliveira ML; Caldas LV
    Radiat Prot Dosimetry; 2004; 111(1):17-20. PubMed ID: 15367762
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Batch homogeneity of LiF(Mg,Cu,P)-GR200 and LiF(Mg,Cu,P)-MCP-NS TL detectors for use as extremity dosemeters at ENEA personal dosimetry service.
    Mariotti F; Uleri G; Fantuzzi E
    Radiat Prot Dosimetry; 2006; 120(1-4):283-8. PubMed ID: 16702241
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.