These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
96 related articles for article (PubMed ID: 12389103)
1. A survey of radiation dose associated with pediatric plain-film chest X-ray examinations. Hintenlang KM; Williams JL; Hintenlang DE Pediatr Radiol; 2002 Nov; 32(11):771-7. PubMed ID: 12389103 [TBL] [Abstract][Full Text] [Related]
2. Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols. Hurwitz LM; Yoshizumi TT; Goodman PC; Frush DP; Nguyen G; Toncheva G; Lowry C J Comput Assist Tomogr; 2007; 31(4):544-9. PubMed ID: 17882029 [TBL] [Abstract][Full Text] [Related]
3. A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms. DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; O'Daniel J; McNitt-Gray MF Phys Med Biol; 2005 Sep; 50(17):3989-4004. PubMed ID: 16177525 [TBL] [Abstract][Full Text] [Related]
4. [Radiation exposure of children in pediatric radiology. Part 3: Conversion coefficients for reconstruction of organ doses achieved during chest X-ray examinations]. Seidenbusch MC; Regulla D; Schneider K Rofo; 2008 Dec; 180(12):1061-81. PubMed ID: 19235700 [TBL] [Abstract][Full Text] [Related]
5. [Radiation exposure of children in pediatric radiology. Part 4: Entrance doses achieved during the X-ray examination of the chest]. Seidenbusch MC; Schneider K Rofo; 2008 Dec; 180(12):1082-103. PubMed ID: 19009497 [TBL] [Abstract][Full Text] [Related]
6. [Determination of the effective dose for CT examinations and influence of the setup parameters]. Koller F; Roth J Rofo; 2007 Jan; 179(1):38-45. PubMed ID: 17203442 [TBL] [Abstract][Full Text] [Related]
7. Organ and effective doses in newborn patients during helical multislice computed tomography examination. Staton RJ; Lee C; Lee C; Williams MD; Hintenlang DE; Arreola MM; Williams JL; Bolch WE Phys Med Biol; 2006 Oct; 51(20):5151-66. PubMed ID: 17019030 [TBL] [Abstract][Full Text] [Related]
8. Estimating effective dose to pediatric patients undergoing interventional radiology procedures using anthropomorphic phantoms and MOSFET dosimeters. Miksys N; Gordon CL; Thomas K; Connolly BL AJR Am J Roentgenol; 2010 May; 194(5):1315-22. PubMed ID: 20410420 [TBL] [Abstract][Full Text] [Related]
9. 2007 recommendations of the ICRP change basis for estimation of the effective dose: what is the impact on radiation dose assessment of patient and personnel? Boetticher Hv; Lachmund J; Looe HK; Hoffmann W; Poppe B Rofo; 2008 May; 180(5):391-5. PubMed ID: 18438741 [TBL] [Abstract][Full Text] [Related]
10. Assessment of organ absorbed doses and estimation of effective doses from pediatric anthropomorphic phantom measurements for multi-detector row CT with and without automatic exposure control. Brisse HJ; Robilliard M; Savignoni A; Pierrat N; Gaboriaud G; De Rycke Y; Neuenschwander S; Aubert B; Rosenwald JC Health Phys; 2009 Oct; 97(4):303-14. PubMed ID: 19741359 [TBL] [Abstract][Full Text] [Related]
11. Survey of doses and frequency of X-ray examinations on children at the intensive care unit of a large reference pediatric hospital. Pedrosa de Azevedo AC; Osibote AO; Bastos Boechat MC Appl Radiat Isot; 2006 Dec; 64(12):1637-42. PubMed ID: 16877002 [TBL] [Abstract][Full Text] [Related]
12. Assessment of the problem: pediatric doses in screen-film and digital radiography. Huda W Pediatr Radiol; 2004 Oct; 34 Suppl 3():S173-82; discussion S234-41. PubMed ID: 15558259 [TBL] [Abstract][Full Text] [Related]
13. Patient dose estimation for multi-detector-row CT examinations. Nishizawa K; Mori S; Ohno M; Yanagawa N; Yoshida T; Akahane K; Iwai K; Wada S Radiat Prot Dosimetry; 2008; 128(1):98-105. PubMed ID: 17595212 [TBL] [Abstract][Full Text] [Related]
14. Patient dose calculated from exposure parameters on abdominal X-ray examination: phantom experiments and clinical application. Nakagiri Y; Sugita K; Takeda Y; Kanazawa S; Hiraki Y Radiat Med; 2000; 18(6):335-41. PubMed ID: 11153685 [TBL] [Abstract][Full Text] [Related]
15. [Radiation exposure of children in pediatric radiology. Part 5: organ doses in chest radiography]. Seidenbusch MC; Schneider K Rofo; 2009 May; 181(5):454-71. PubMed ID: 19391068 [TBL] [Abstract][Full Text] [Related]
16. Organ doses and effective doses in pediatric radiography: patient-dose survey in Finland. Kiljunen T; Tietäväinen A; Parviainen T; Viitala A; Kortesniemi M Acta Radiol; 2009 Jan; 50(1):114-24. PubMed ID: 19096954 [TBL] [Abstract][Full Text] [Related]
17. Organ and effective dose evaluation in diagnostic radiology based on in-phantom dose measurements with novel photodiode-dosemeters. Kawaura C; Aoyama T; Koyama S; Achiwa M; Mori M Radiat Prot Dosimetry; 2006; 118(4):421-30. PubMed ID: 16439515 [TBL] [Abstract][Full Text] [Related]
18. Normalized organ doses and effective doses to a reference Indian adult male in conventional medical diagnostic x-ray examinations. Biju K; Nagarajan PS Health Phys; 2006 Mar; 90(3):217-22. PubMed ID: 16505618 [TBL] [Abstract][Full Text] [Related]
19. Method of patient dose evaluation in the angiographic and interventional radiology procedures. Rivolta A; Emanuelli S; Tessarin C; Bresciani S; Genovese MG; Rogge D; Scielzo G Radiol Med; 2005; 110(5-6):689-98. PubMed ID: 16437054 [TBL] [Abstract][Full Text] [Related]
20. Effective dose estimation for pediatric upper gastrointestinal examinations using an anthropomorphic phantom set and metal oxide semiconductor field-effect transistor (MOSFET) technology. Emigh B; Gordon CL; Connolly BL; Falkiner M; Thomas KE Pediatr Radiol; 2013 Sep; 43(9):1108-16. PubMed ID: 23529628 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]