These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
114 related articles for article (PubMed ID: 12408263)
1. Inappropriate high-rate ventricular pacing in a patient with a defibrillator. Zaim S; Sunthorn H; Adatte JJ; Kürsteiner K; Burgener D; Huehn C Europace; 2002 Oct; 4(4):427-30. PubMed ID: 12408263 [TBL] [Abstract][Full Text] [Related]
2. Runaway pacemaker in an implantable cardioverter defibrillator. Carpenter CM; Galvin J; Guy M; McGovern BA J Cardiovasc Electrophysiol; 1998 Sep; 9(9):1008-11. PubMed ID: 9786083 [TBL] [Abstract][Full Text] [Related]
3. Strategies to avoid inappropriate therapies due to ventricular double detection in biventricular pacing implantable cardioverter/defibrillators. Kolb C; Zrenner B; Schreieck J; Schmitt C Eur J Heart Fail; 2003 Aug; 5(4):523-6. PubMed ID: 12921814 [TBL] [Abstract][Full Text] [Related]
4. Inappropriate implantable cardioverter-defibrillator shocks due to temporary epicardial pacing. Gelissen M; Debie L; van Opstal J Europace; 2010 Nov; 12(11):1648. PubMed ID: 20543194 [TBL] [Abstract][Full Text] [Related]
5. A single implantable cardioverter-defibrillator shock unmasking an electrical storm of 389 ventricular tachycardia episodes triggering device therapies. Arias MA; Valverde I; Puchol A; Castellanos E; Rodríguez-Padial L; Sánchez AM; Alvarez-Temiño M; Palomino M Am J Emerg Med; 2008 Nov; 26(9):1066.e1-3. PubMed ID: 19091283 [TBL] [Abstract][Full Text] [Related]
6. Atrioventricular sequential pacing by an implantable cardioverter defibrillator during sustained ventricular tachycardia: what is the mechanism? Wood MA; Ellenbogen KA; Shepard RK; Clemo HS J Cardiovasc Electrophysiol; 2002 Dec; 13(12):1309-10. PubMed ID: 12521353 [No Abstract] [Full Text] [Related]
7. Inappropriate shock delivery due to ventricular double detection with a biventricular pacing implantable cardioverter defibrillator. Schreieck J; Zrenner B; Kolb C; Ndrepepa G; Schmitt C Pacing Clin Electrophysiol; 2001 Jul; 24(7):1154-7. PubMed ID: 11475833 [TBL] [Abstract][Full Text] [Related]
8. Sensing failure in a tiered therapy implantable cardioverter defibrillator: role of auto adjustable gain. Wase A; Natale A; Dhala AA; Deshpande S; Sra JS; Blanck Z; Maglio C; Jazayeri MR; Akhtar M Pacing Clin Electrophysiol; 1995 Jun; 18(6):1327-30. PubMed ID: 7659589 [TBL] [Abstract][Full Text] [Related]
9. An inappropriate pacing threshold increase after repeated electrical storm in a patient with implantable cardioverter defibrillator. Zhu Y; Gu X; Xu C BMC Cardiovasc Disord; 2017 Oct; 17(1):265. PubMed ID: 29037154 [TBL] [Abstract][Full Text] [Related]
10. Multicenter experience with a pectoral unipolar implantable cardioverter-defibrillator. Active Can Investigators. Bardy GH; Yee R; Jung W J Am Coll Cardiol; 1996 Aug; 28(2):400-10. PubMed ID: 8800117 [TBL] [Abstract][Full Text] [Related]
11. Right ventricular pacing is an independent predictor for ventricular tachycardia/ventricular fibrillation occurrence and heart failure events in patients with an implantable cardioverter-defibrillator. Gardiwal A; Yu H; Oswald H; Luesebrink U; Ludwig A; Pichlmaier AM; Drexler H; Klein G Europace; 2008 Mar; 10(3):358-63. PubMed ID: 18308756 [TBL] [Abstract][Full Text] [Related]
12. Outcomes of defibrillator therapy in catecholaminergic polymorphic ventricular tachycardia. Roses-Noguer F; Jarman JW; Clague JR; Till J Heart Rhythm; 2014 Jan; 11(1):58-66. PubMed ID: 24120999 [TBL] [Abstract][Full Text] [Related]
13. Inappropriate implantable cardioverter-defibrillator shock due to external alternating current leak: report of two cases. Chan NY; Wai-Ling Ho L Europace; 2005 Mar; 7(2):193-6. PubMed ID: 15763537 [TBL] [Abstract][Full Text] [Related]
14. Treatment of drug refractory ventricular tachycardia by biventricular pacing. Garrigue S; Barold SS; Hocini M; Jaïs P; Haïssaguerre M; Clementy J Pacing Clin Electrophysiol; 2000 Nov; 23(11 Pt 1):1700-2. PubMed ID: 11138311 [TBL] [Abstract][Full Text] [Related]
15. Subcutaneous implantable cardioverter-defibrillator: First single-center experience with other cardiac implantable electronic devices. Kuschyk J; Stach K; Tülümen E; Rudic B; Liebe V; Schimpf R; Borggrefe M; Röger S Heart Rhythm; 2015 Nov; 12(11):2230-8. PubMed ID: 26073595 [TBL] [Abstract][Full Text] [Related]
16. Eligibility for the Subcutaneous Implantable Cardioverter-Defibrillator in Patients With Hypertrophic Cardiomyopathy. Francia P; Adduci C; Palano F; Semprini L; Serdoz A; Montesanti D; Santini D; Musumeci B; Salvati A; Volpe M; Autore C J Cardiovasc Electrophysiol; 2015 Aug; 26(8):893-899. PubMed ID: 25996259 [TBL] [Abstract][Full Text] [Related]
17. Multiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device. Francisco GM; Sharma S; Dougherty AH; Kantharia BK Cardiol J; 2009; 16(5):473-6. PubMed ID: 19753529 [TBL] [Abstract][Full Text] [Related]
18. Inappropriate therapy and fatal proarrhythmia by an implantable cardioverter-defibrillator. Vollmann D; Lüthje L; Vonhof S; Unterberg C Heart Rhythm; 2005 Mar; 2(3):307-9. PubMed ID: 15851324 [No Abstract] [Full Text] [Related]
19. Shock Reduction With Antitachycardia Pacing Before and During Charging for Fast Ventricular Tachycardias in Patients With Implantable Defibrillators. Dallaglio PD; Anguera I; Martínez Ferrer JB; Pérez L; Viñolas X; Porres JM; Fontenla A; Alzueta J; Martínez JG; Rodríguez A; Basterra N; Sabaté X Rev Esp Cardiol (Engl Ed); 2018 Sep; 71(9):709-717. PubMed ID: 29242102 [TBL] [Abstract][Full Text] [Related]
20. [Transesophageal ventricular stimulation and ventricular tachycardia in the period before implantation of a cardioverter-defibrillator]. Pella J; Bodnár J; Stancák B; Misíkoá S; Sedlák J; Cizmárik P Vnitr Lek; 1994 Oct; 40(10):663-6. PubMed ID: 7810086 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]