  • 1. A basic study of some normoxic polymer gel dosimeters.
    De Deene Y; Hurley C; Venning A; Vergote K; Mather M; Healy BJ; Baldock C
    Phys Med Biol; 2002 Oct; 47(19):3441-63. PubMed ID: 12408474
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels.
    De Deene Y; Vergote K; Claeys C; De Wagter C
    Phys Med Biol; 2006 Feb; 51(3):653-73. PubMed ID: 16424587
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Severe dose inaccuracies caused by an oxygen-antioxidant imbalance in normoxic polymer gel dosimeters.
    Sedaghat M; Bujold R; Lepage M
    Phys Med Biol; 2011 Feb; 56(3):601-25. PubMed ID: 21220843
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The influence of cooling rate on the accuracy of normoxic polymer gel dosimeters.
    De Deene Y; Pittomvils G; Visalatchi S
    Phys Med Biol; 2007 May; 52(10):2719-28. PubMed ID: 17473347
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Radiological properties of normoxic polymer gel dosimeters.
    Venning AJ; Nitschke KN; Keall PJ; Baldock C
    Med Phys; 2005 Apr; 32(4):1047-53. PubMed ID: 15895589
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere.
    Fong PM; Keil DC; Does MD; Gore JC
    Phys Med Biol; 2001 Dec; 46(12):3105-13. PubMed ID: 11768494
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The impact of the oxygen scavenger on the dose-rate dependence and dose sensitivity of MAGIC type polymer gels.
    Khan M; Heilemann G; Kuess P; Georg D; Berg A
    Phys Med Biol; 2018 Mar; 63(6):06NT01. PubMed ID: 29528035
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Basic investigations on the performance of a normoxic polymer gel with tetrakis-hydroxy-methyl-phosphonium chloride as an oxygen scavenger: reproducibility, accuracy, stability, and dose rate dependence.
    Bayreder C; Georg D; Moser E; Berg A
    Med Phys; 2006 Jul; 33(7):2506-18. PubMed ID: 16898454
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MAGIC-type polymer gel for three-dimensional dosimetry: intensity-modulated radiation therapy verification.
    Gustavsson H; Karlsson A; Bäck SA; Olsson LE; Haraldsson P; Engström P; Nyström H
    Med Phys; 2003 Jun; 30(6):1264-71. PubMed ID: 12852552
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Introducing gel dosimetry in a clinical environment: customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy.
    Crescenti RA; Scheib SG; Schneider U; Gianolini S
    Med Phys; 2007 Apr; 34(4):1286-97. PubMed ID: 17500460
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A study of a normoxic polymer gel dosimeter comprising methacrylic acid, gelatin and tetrakis (hydroxymethyl) phosphonium chloride (MAGAT).
    Hurley C; Venning A; Baldock C
    Appl Radiat Isot; 2005 Oct; 63(4):443-56. PubMed ID: 16026995
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters.
    Mather ML; De Deene Y; Whittaker AK; Simon GP; Rutgers R; Baldock C
    Phys Med Biol; 2002 Dec; 47(24):4397-409. PubMed ID: 12539980
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Investigation of tetrakis hydroxymethyl phosphonium chloride as an antioxidant for use in x-ray computed tomography polyacrylamide gel dosimetry.
    Jirasek A; Hilts M; Shaw C; Baxter P
    Phys Med Biol; 2006 Apr; 51(7):1891-906. PubMed ID: 16552112
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A preliminary study of the novel application of normoxic polymer gel dosimeters for the measurement of CTDI on diagnostic x-ray CT scanners.
    Hill B; Venning AJ; Baldock C
    Med Phys; 2005 Jun; 32(6):1589-97. PubMed ID: 16013718
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters.
    De Deene Y; Venning A; Hurley C; Healy BJ; Baldock C
    Phys Med Biol; 2002 Jul; 47(14):2459-70. PubMed ID: 12171334
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Preliminary studies on the role and reactions of tetrakis(hydroxymethyl)phosphonium chloride in polyacrylamide gel dosimeters.
    Sedaghat M; Bujold R; Lepage M
    Phys Med Biol; 2012 Oct; 57(19):5981-94. PubMed ID: 22964826
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polymer gel dosimeters with reduced toxicity: a preliminary investigation of the NMR and optical dose-response using different monomers.
    Senden RJ; De Jean P; McAuley KB; Schreiner LJ
    Phys Med Biol; 2006 Jul; 51(14):3301-14. PubMed ID: 16825731
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Linear energy transfer dependence of a normoxic polymer gel dosimeter investigated using proton beam absorbed dose measurements.
    Gustavsson H; Bäck SA; Medin J; Grusell E; Olsson LE
    Phys Med Biol; 2004 Sep; 49(17):3847-55. PubMed ID: 15470909
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Examination of THPC as an oxygen scavenger impacting VIC dosimeter thermal stability and comparison of NVP-containing polymer gel dosimeters.
    Jaszczak M; Kolesińska B; Wach R; Maras P; Dudek M; Kozicki M
    Phys Med Biol; 2019 Jan; 64(3):035019. PubMed ID: 30577036
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Investigation of the PAGAT polymer gel dosimeter using magnetic resonance imaging.
    Venning AJ; Hill B; Brindha S; Healy BJ; Baldock C
    Phys Med Biol; 2005 Aug; 50(16):3875-88. PubMed ID: 16077233
    [TBL] [Abstract][Full Text] [Related]  