These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
136 related articles for article (PubMed ID: 12411898)
1. Comprehensive assessment of patent ductus arteriosus by echocardiography before transcatheter closure. Ramaciotti C; Lemler MS; Moake L; Zellers TM J Am Soc Echocardiogr; 2002 Oct; 15(10 Pt 2):1154-9. PubMed ID: 12411898 [TBL] [Abstract][Full Text] [Related]
2. Echocardiographic versus Angiographic Measurement of the Patent Ductus Arteriosus in Extremely Low Birth Weight Infants and the Utility of Echo Guidance for Transcatheter Closure. Paudel G; Johnson JN; Philip R; Tailor N; Fahnhorst S; Briceno-Medina M; Stecchi N; Waller BR; Sathanandam S J Am Soc Echocardiogr; 2021 Oct; 34(10):1086-1094. PubMed ID: 34139301 [TBL] [Abstract][Full Text] [Related]
3. Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device. Philip R; Waller BR; Agrawal V; Wright D; Arevalo A; Zurakowski D; Sathanandam S Catheter Cardiovasc Interv; 2016 Feb; 87(2):310-7. PubMed ID: 26525611 [TBL] [Abstract][Full Text] [Related]
4. Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder. Bilici M; Demir F; Akın A; Türe M; Balık H; Kuyumcu M Pediatr Cardiol; 2017 Dec; 38(8):1598-1605. PubMed ID: 28828684 [TBL] [Abstract][Full Text] [Related]
5. Percutaneous closure of the patent ductus arteriosus using the Nit-Occlud PDA-R (reverse) device: initial experience reporting immediate and short-term results. Peirone A; Diaz J; Contreras A; Banille E; Cabrera M; Spillmann A; Bueno N; Juaneda E J Invasive Cardiol; 2011 Dec; 23(12):513-6. PubMed ID: 22147399 [TBL] [Abstract][Full Text] [Related]
6. Prospective evaluation of the feasibility, safety, and efficacy of Cocoon Duct Occluder for transcatheter closure of large patent ductus arteriosus: A single-center study with short- and medium-term follow-up results. Sinha SK; Razi M; Pandey RN; Kumar P; Krishna V; Jha MJ; Mishra V; Asif M; Abdali N; Tewari P; Thakur R; Pandey U; Varma CM Anatol J Cardiol; 2017 Nov; 18(5):321-327. PubMed ID: 29145233 [TBL] [Abstract][Full Text] [Related]
7. Catheter Closure Through a Venous Approach of Patent Ductus Arteriosus in Small Pediatric Patients Using Combined Angiographic and Echocardiographic Guidance. Thanopoulos BV; Ninios V; Dardas P; Giannopoulos A; Deleanou D; Iancovici S Am J Cardiol; 2016 Nov; 118(10):1558-1562. PubMed ID: 27670796 [TBL] [Abstract][Full Text] [Related]
8. Echocardiographic Versus Angiographic Assessment of Patent Arterial Duct in Percutaneous Closure: Towards X-ray Free Duct Occlusion? Carmo Mendes I; Heard H; Peacock K; Krasemann T; Morgan GJ Pediatr Cardiol; 2017 Feb; 38(2):302-307. PubMed ID: 28078384 [TBL] [Abstract][Full Text] [Related]
9. Intracardiac Echocardiography as a Guide for Transcatheter Closure of Patent Ductus Arteriosus. Yoshimoto H; Yasuto M; Inoue T; Kagiyama Y; Teramachi Y; Takase R; Koteda Y; Fukumoto Y; Iemura M; Suda K J Interv Cardiol; 2020; 2020():5147193. PubMed ID: 32802008 [TBL] [Abstract][Full Text] [Related]
11. Transcatheter Patent Ductus Arteriosus Occlusion in Small Infants. Schwartz MC; Nykanen D; Winner LH; Perez J; McMahan M; Munro HM; Suguna Narasimhulu S Congenit Heart Dis; 2016 Dec; 11(6):647-655. PubMed ID: 27225896 [TBL] [Abstract][Full Text] [Related]
12. Short-Term Outcomes of Patent Ductus Arteriosus Closure With New Occlutech® Duct Occluder: A Multicenter Study. Dedeoglu R; Bilici M; Demir F; Demir F; Acar OÇ; Hallioglu O; Pac A; Kiziltas A; Karabel D; Kula S; Cimen D; Baspinar O; Atik SU; Saltik IL J Interv Cardiol; 2016 Jun; 29(3):325-31. PubMed ID: 27090770 [TBL] [Abstract][Full Text] [Related]
13. Use of the amplatzer vascular plug II device to occlude different types of patent ductus arteriosus in pediatric patients. Garay FJ; Aguirre D; Cárdenas L; Springmuller D; Heusser F J Interv Cardiol; 2015 Apr; 28(2):198-204. PubMed ID: 25832322 [TBL] [Abstract][Full Text] [Related]
15. A Retrospective Study of 1,526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus. Jin M; Liang YM; Wang XF; Guo BJ; Zheng K; Gu Y; Lyu ZY Chin Med J (Engl); 2015 Sep; 128(17):2284-9. PubMed ID: 26315073 [TBL] [Abstract][Full Text] [Related]
16. The new Occlutech® PDA occluder: Initial human experience. Abdelbasit MA; Alwi M; Kandavello G; Che Mood M; Samion H; Hijazi ZM Catheter Cardiovasc Interv; 2015 Jul; 86(1):94-9. PubMed ID: 25675888 [TBL] [Abstract][Full Text] [Related]
17. [Transcatheter closure for patent ductus arteriosus in children]. Shen XQ; Zhou SH; Fang ZF; Hu XQ; Qi SS; Chen GR; Wang C Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2006 Oct; 31(5):782-5. PubMed ID: 17062952 [TBL] [Abstract][Full Text] [Related]
18. Comparative, multidimensional imaging of patent ductus arteriosus and a proposed update to the morphology classification system for dogs. Doocy KR; Saunders AB; Gordon SG; Jeffery N J Vet Intern Med; 2018 Mar; 32(2):648-657. PubMed ID: 29460426 [TBL] [Abstract][Full Text] [Related]
19. The new Occlutech(®) patent ductus arteriosus occluder: Single centre experience. Boudjemline Y Arch Cardiovasc Dis; 2016; 109(6-7):384-9. PubMed ID: 26988839 [TBL] [Abstract][Full Text] [Related]
20. Long-term follow-up results of lung perfusion studies after transcatheter closure of patent ductus arteriosus. Demir F; Celebi A; Saritas T; Erdem A; Demir H; Firat MF; Polat TB Congenit Heart Dis; 2013; 8(2):159-66. PubMed ID: 22897893 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]