These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 12414064)

  • 1. Haemodynamic changes during off-pump surgery.
    Velissaris T; Tang A; Jonas M; Ohri S
    Eur J Cardiothorac Surg; 2002 Nov; 22(5):852; author reply 853. PubMed ID: 12414064
    [No Abstract]   [Full Text] [Related]  

  • 2. Indications for pulmonary artery flow-directed catheters.
    Young D
    Br J Hosp Med; 1990 Dec; 44(6):413-5. PubMed ID: 2081313
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Application of intraoperative arterial pressure-based cardiac output monitoring for patients undergoing coronary artery bypass grafting surgery.
    Lu JK; Zhu C; Jing H; Wang YJ; Qing EM
    Chin Med J (Engl); 2012 Jun; 125(12):2099-103. PubMed ID: 22884136
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hemodynamic advantages of right heart decompression during off-pump surgery.
    Velissaris T; Jonas MM; Ohri SK
    Asian Cardiovasc Thorac Ann; 2010 Feb; 18(1):17-21. PubMed ID: 20124291
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre.
    Cho YJ; Koo CH; Kim TK; Hong DM; Jeon Y
    J Clin Monit Comput; 2016 Dec; 30(6):771-782. PubMed ID: 26429135
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Is less always more?: modalities of extended haemodynamic monitoring for single-lung ventilation].
    Rex S
    Anaesthesist; 2009 Nov; 58(11):1081-2. PubMed ID: 19885648
    [No Abstract]   [Full Text] [Related]  

  • 7. Perioperative myocardial ischemia: early diagnosis using the pulmonary artery catheter.
    Sanchez R; Wee M
    J Cardiothorac Vasc Anesth; 1991 Dec; 5(6):604-7. PubMed ID: 1768825
    [No Abstract]   [Full Text] [Related]  

  • 8. Evaluation of serial haemodynamic changes during coronary artery anastomoses in patients undergoing off-pump coronary artery bypass graft surgery: initial experiences using two deep pericardial stay sutures and octopus tissue stabilizer.
    Shinn HK; Oh YJ; Kim SH; Lee JH; Lee CS; Kwak YL
    Eur J Cardiothorac Surg; 2004 Jun; 25(6):978-84. PubMed ID: 15144998
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Continuous assessment of right ventricular ejection fraction: new pulmonary artery catheter versus transoesophageal echocardiography.
    Zink W; Nöll J; Rauch H; Bauer H; Desimone R; Martin E; Böttiger BW
    Anaesthesia; 2004 Nov; 59(11):1126-32. PubMed ID: 15479324
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Compromised pulmonary artery catheter injection following sternal retraction.
    Mantia AM; Kasraie N; Merchant WT
    J Cardiothorac Anesth; 1988 Jun; 2(3):403-5. PubMed ID: 17175582
    [No Abstract]   [Full Text] [Related]  

  • 11. [Reduction in the use of pulmonary artery catheter for cardiovascular surgery].
    Handa F; Kyo SE; Miyao H
    Masui; 2003 Apr; 52(4):420-3. PubMed ID: 12728497
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intraoperative monitoring during cardiac surgery: some observations.
    Levinson MM
    Heart Surg Forum; 1999; 2(2):111-4. PubMed ID: 11276466
    [No Abstract]   [Full Text] [Related]  

  • 13. Haemodynamic and EKG changes in patients undergoing minimally invasive direct coronary artery bypass.
    Baraka AS; Haroun-Bizri S; Shabb BR; Khoury SS; Chehab IR; Jalbout MI
    Middle East J Anaesthesiol; 2002 Feb; 16(4):387-96. PubMed ID: 11949201
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Routine Use of the Pulmonary Artery Catheter Should Be Abandoned.
    Youssef N; Whitlock RP
    Can J Cardiol; 2017 Jan; 33(1):135-141. PubMed ID: 27916322
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Anomalous right coronary artery originating from the left sinus of Valsalva.
    Béïque F; De Tran QH; Ma F; Rudski L; Daves S; Angelini P
    J Cardiothorac Vasc Anesth; 2004 Dec; 18(6):788-98. PubMed ID: 15650996
    [No Abstract]   [Full Text] [Related]  

  • 16. [Is there any indication for perioperative use of the pulmonary artery catheter?].
    Schürholz T; Marx G
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2012 Feb; 47(2):110-7. PubMed ID: 22402850
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Minimally invasive direct coronary artery bypass and off-pump coronary artery bypass surgery: anesthetic considerations.
    Bainbridge D; Cheng DC
    Anesthesiol Clin; 2008 Sep; 26(3):437-52. PubMed ID: 18765216
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transoesophageal echocardiography during orthotopic liver transplantation.
    Acosta Martínez J; López-Herrera Rodríguez D; González Rubio D; López Romero JL
    Rev Esp Anestesiol Reanim; 2017 Nov; 64(9):522-527. PubMed ID: 28385292
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A new, minimally invasive technique for measuring cardiac index: clinical comparison of continuous cardiac dynamic monitoring and pulmonary artery catheter methods.
    Berridge JC; Warring-Davies K; Bland JM; Quinn AC
    Anaesthesia; 2009 Sep; 64(9):961-7. PubMed ID: 19686480
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effects of on-pump and off-pump coronary artery bypass grafting on intraoperative graft flow in arterial and venous conduits defined by a flow/pressure ratio.
    Balacumaraswami L; Abu-Omar Y; Selvanayagam J; Pigott D; Taggart DP
    J Thorac Cardiovasc Surg; 2008 Mar; 135(3):533-9. PubMed ID: 18329465
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.