These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
384 related articles for article (PubMed ID: 12434609)
21. Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting. Missant C; Rex S; Wouters PF Eur J Anaesthesiol; 2008 Mar; 25(3):243-8. PubMed ID: 17996125 [TBL] [Abstract][Full Text] [Related]
22. Cardiac output measurement by bioimpedance and noninvasive pulse contour analysis compared with the continuous pulmonary artery thermodilution technique. Maass SW; Roekaerts PM; Lancé MD J Cardiothorac Vasc Anesth; 2014 Jun; 28(3):534-9. PubMed ID: 24746334 [TBL] [Abstract][Full Text] [Related]
23. The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method. Thonnerieux M; Alexander B; Binet C; Obadia JF; Bastien O; Desebbe O Anesth Analg; 2015 Aug; 121(2):383-91. PubMed ID: 25902321 [TBL] [Abstract][Full Text] [Related]
24. Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre. Cho YJ; Koo CH; Kim TK; Hong DM; Jeon Y J Clin Monit Comput; 2016 Dec; 30(6):771-782. PubMed ID: 26429135 [TBL] [Abstract][Full Text] [Related]
25. Measurement of cardiac output before and after cardiopulmonary bypass: Comparison among aortic transit-time ultrasound, thermodilution, and noninvasive partial CO2 rebreathing. Botero M; Kirby D; Lobato EB; Staples ED; Gravenstein N J Cardiothorac Vasc Anesth; 2004 Oct; 18(5):563-72. PubMed ID: 15578466 [TBL] [Abstract][Full Text] [Related]
27. Evaluation of the use of the fourth version FloTrac system in cardiac output measurement before and after cardiopulmonary bypass. Lin SY; Chou AH; Tsai YF; Chang SW; Yang MW; Ting PC; Chen CY J Clin Monit Comput; 2018 Oct; 32(5):807-815. PubMed ID: 29039063 [TBL] [Abstract][Full Text] [Related]
28. Esophageal Doppler and thermodilution are not interchangeable for determination of cardiac output. Collins S; Girard F; Boudreault D; Chouinard P; Normandin L; Couture P; Caron MJ; Ruel M Can J Anaesth; 2005 Nov; 52(9):978-85. PubMed ID: 16251566 [TBL] [Abstract][Full Text] [Related]
29. Validation of a continuous, arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial. McGee WT; Horswell JL; Calderon J; Janvier G; Van Severen T; Van den Berghe G; Kozikowski L Crit Care; 2007; 11(5):R105. PubMed ID: 17880692 [TBL] [Abstract][Full Text] [Related]
31. [Comparison of cardiac output measurement in critical patients using transesophageal Doppler or thermodilution: a preliminary report]. Andresen M; Henríquez M; Mercado M; Farías G; Castillo C; Benítez C; Dougnac A Rev Med Chil; 2005 Jul; 133(7):761-6. PubMed ID: 16341381 [TBL] [Abstract][Full Text] [Related]
32. [Monitoring cardiac output: esophageal doppler vs thermodilution]. Leone D; Servillo G; De Robertis E; Rossano F; Tufano R Minerva Anestesiol; 1998; 64(7-8):351-6. PubMed ID: 9796245 [TBL] [Abstract][Full Text] [Related]