These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 12435942)

  • 1. Improvement of external fixator performance in type C pelvic ring injuries by plating of the pubic symphysis: an experimental study on 12 external fixators.
    Ponson KJ; Hoek van Dijke GA; Joosse P; Snijders CJ; Agnew SG
    J Trauma; 2002 Nov; 53(5):907-12; discussion 912-3. PubMed ID: 12435942
    [TBL] [Abstract][Full Text] [Related]  

  • 2. External fixators for pelvic fractures: comparison of the stiffness of current systems.
    Ponsen KJ; Hoek van Dijke GA; Joosse P; Snijders CJ
    Acta Orthop Scand; 2003 Apr; 74(2):165-71. PubMed ID: 12807323
    [TBL] [Abstract][Full Text] [Related]  

  • 3. External fixation of the pelvic ring: an experimental study on the role of pin diameter, pin position, and parasymphyseal fixator pins.
    Ponsen KJ; Joosse P; Van Dijke GA; Snijders CJ
    Acta Orthop; 2007 Oct; 78(5):648-53. PubMed ID: 17966024
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.
    Vigdorchik JM; Esquivel AO; Jin X; Yang KH; Onwudiwe NA; Vaidya R
    J Orthop Surg Res; 2012 Sep; 7():31. PubMed ID: 23017093
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Treatment of old Tile B1 pelvic fracture by staged pelvic closure using external fixator combined with reconstruction plate].
    Tian Y; Fu Q
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Mar; 22(3):324-7. PubMed ID: 18396713
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Definitive External Fixation for Anterior Stabilization of Combat-related Pelvic Ring Injuries, With or Without Sacroiliac Fixation.
    Hoyt BW; Lundy AE; Purcell RL; Harrington CJ; Gordon WT
    Clin Orthop Relat Res; 2020 Apr; 478(4):779-789. PubMed ID: 32229751
    [TBL] [Abstract][Full Text] [Related]  

  • 7. When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study.
    Mcdonald E; Theologis AA; Horst P; Kandemir U; Pekmezci M
    Eur J Trauma Emerg Surg; 2015 Dec; 41(6):665-71. PubMed ID: 26038006
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical comparison of supraacetabular external fixation and anterior pelvic bridge plating.
    Çavuşoğlu AT; Erbay FK; Özsoy MH; Demir T
    Proc Inst Mech Eng H; 2017 Oct; 231(10):931-937. PubMed ID: 28689459
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Associated injuries in severe pelvic trauma].
    Siegmeth A; Müllner T; Kukla C; Vécsei V
    Unfallchirurg; 2000 Jul; 103(7):572-81. PubMed ID: 10969545
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical comparison of posterior pelvic ring fixation.
    Yinger K; Scalise J; Olson SA; Bay BK; Finkemeier CG
    J Orthop Trauma; 2003 Aug; 17(7):481-7. PubMed ID: 12902785
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Can a modified anterior external fixator provide posterior compression of AP compression type III pelvic injuries?
    Sellei RM; Schandelmaier P; Kobbe P; Knobe M; Pape HC
    Clin Orthop Relat Res; 2013 Sep; 471(9):2862-8. PubMed ID: 23604604
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical comparative study on external fixators of new configurations in the treatment of Tile C pelvic injury.
    Zhao Y; Ma Y; Wu H; Lian W; Li W; Jiang W
    Sci Rep; 2024 Apr; 14(1):9544. PubMed ID: 38664538
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modified less invasive anterior subcutaneous fixator for unstable Tile-C-pelvic ring fractures: a biomechanical study.
    Becker CA; Kammerlander C; Kußmaul AC; Woiczinski M; Thorwächter C; Zeckey C; Sommer F; Linhart C; Weidert S; Suero EM; Böcker W; Greiner A
    Biomed Eng Online; 2019 Mar; 18(1):38. PubMed ID: 30925898
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Early failure of symphysis pubis plating.
    Eastman JG; Krieg JC; Routt ML
    Injury; 2016 Aug; 47(8):1707-12. PubMed ID: 27282685
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A biomechanical study comparing minimally invasive anterior pelvic ring fixation techniques to external fixation.
    MacCormick LM; Chen F; Gilbertson J; Khan S; Schroder LK; Bechtold JE; Cole PA
    Injury; 2019 Feb; 50(2):251-255. PubMed ID: 30447984
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fixation of Anterior Pelvic Ring Injuries.
    Wojahn RD; Gardner MJ
    J Am Acad Orthop Surg; 2019 Sep; 27(18):667-676. PubMed ID: 30889037
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A simple supraacetabular external fixation for pelvic ring fractures].
    Gänsslen A; Pohlemann T; Krettek C
    Oper Orthop Traumatol; 2005 Sep; 17(3):296-312. PubMed ID: 16132252
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of pin location on stability of pelvic external fixation.
    Kim WY; Hearn TC; Seleem O; Mahalingam E; Stephen D; Tile M
    Clin Orthop Relat Res; 1999 Apr; (361):237-44. PubMed ID: 10212618
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Anterior internal fixator versus a femoral distractor and external fixation for sacroiliac joint compression and single stance gait testing: a mechanical study in synthetic bone.
    Vigdorchik JM; Esquivel AO; Jin X; Yang KH; Vaidya R
    Int Orthop; 2013 Jul; 37(7):1341-6. PubMed ID: 23645004
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Internal anterior fixators for pelvic ring injuries: Do monaxial pedicle screws provide more stiffness than polyaxial pedicle screws?
    Eagan M; Kim H; Manson TT; Gary JL; Russell JP; Hsieh AH; O'Toole RV; Boulton CL
    Injury; 2015; 46(6):996-1000. PubMed ID: 25697857
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.