These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 12439192)

  • 1. Compressed-air power tools in orthopaedic surgery: exhaust air is a potential source of contamination.
    Sagi HC; DiPasquale T; Sanders R; Herscovici D
    J Orthop Trauma; 2002; 16(10):696-700. PubMed ID: 12439192
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Domestic electric drills in the service of orthopaedic surgery: a potential and preventable source of surgical site infections.
    Küçükdurmaz F; İmren Y; Akkoyunlu Y; Tuncay İ; Şen C
    Acta Orthop Traumatol Turc; 2012; 46(6):455-9. PubMed ID: 23428762
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of Makita electric drills for orthopaedic surgery.
    Railton R; Pringle RM; Shaw A
    J Med Eng Technol; 1988; 12(1):20-3. PubMed ID: 3361600
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Time-dependent bacterial air contamination of sterile fields in a controlled operating room environment: an experimental intervention study.
    Wistrand C; Söderquist B; Sundqvist AS
    J Hosp Infect; 2021 Apr; 110():97-102. PubMed ID: 33516797
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bacterial contamination of compressed air for medical use.
    Bjerring P; Oberg B
    Anaesthesia; 1986 Feb; 41(2):148-50. PubMed ID: 3953987
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pilot study: Internally cooled orthopedic drills - standard sterilization is not enough?
    Bruketa T; Augustin G; Pintarić S; Šeol-Martinec B; Dobrić I; Bakota B
    Acta Clin Croat; 2019 Jun; 58(2):379-385. PubMed ID: 31819337
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of sterile versus non-sterile tourniquets on microbiological colonisation in lower limb surgery.
    Thompson SM; Middleton M; Farook M; Cameron-Smith A; Bone S; Hassan A
    Ann R Coll Surg Engl; 2011 Nov; 93(8):589-90. PubMed ID: 22041233
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pressure sore prevention pads as an infective source in orthopaedic theatres.
    Ranawat VS; Dowell JK; Teare EL
    J Hosp Infect; 2004 Apr; 56(4):318-20. PubMed ID: 15066744
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of Microbial Count on Various Surfaces in Operating Rooms at Different Times of the Day.
    Petersen-Fitts G; Gambone A; Sherwood A; Whaley J; Katz DL; Lima DJL; Sabesan V
    J Surg Orthop Adv; 2018; 27(4):281-285. PubMed ID: 30777827
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Time-dependent contamination of opened sterile operating-room trays.
    Dalstrom DJ; Venkatarayappa I; Manternach AL; Palcic MS; Heyse BA; Prayson MJ
    J Bone Joint Surg Am; 2008 May; 90(5):1022-5. PubMed ID: 18451394
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Elimination of microorganisms from dental operatory compressed air.
    De Ciccio A; Chan EC
    J Can Dent Assoc; 1998 Jan; 64(1):42-7. PubMed ID: 9473876
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Convection warmers--not just hot air.
    Avidan MS; Jones N; Ing R; Khoosal M; Lundgren C; Morrell DF
    Anaesthesia; 1997 Nov; 52(11):1073-6. PubMed ID: 9404170
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Lack of influence of body exhaust gowns on aerobic bacterial surface counts in a mixed-ventilation operating theatre. A study of 62 hip arthroplasties.
    Pasquarella C; Pitzurra O; Herren T; Poletti L; Savino A
    J Hosp Infect; 2003 May; 54(1):2-9. PubMed ID: 12767840
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Environmental bacteriology in the unidirectional (vertical) operating room.
    Bechtol CO
    Arch Surg; 1979 Jul; 114(7):784-8. PubMed ID: 454171
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Role of Sonication for Detection of Infection in Explanted Orthopaedic Trauma Implants.
    Maniar HH; Wingert N; McPhillips K; Foltzer M; Graham J; Bowen TR; Horwitz DS
    J Orthop Trauma; 2016 May; 30(5):e175-80. PubMed ID: 27101168
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dispensing surgical gloves onto the open surgical gown pack does not increase the bacterial contamination rate.
    Kong KC; Sheppard M; Serne G
    J Hosp Infect; 1994 Apr; 26(4):293-6. PubMed ID: 7915290
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analysis of microbial contamination during use and reprocessing of surgical instruments and sterile packaging systems.
    Dreikausen L; Blender B; Trifunovic-Koenig M; Salm F; Bushuven S; Gerber B; Henke M
    PLoS One; 2023; 18(1):e0280595. PubMed ID: 36668667
    [TBL] [Abstract][Full Text] [Related]  

  • 18. What Orthopaedic Operating Room Surfaces Are Contaminated With Bioburden? A Study Using the ATP Bioluminescence Assay.
    Richard RD; Bowen TR
    Clin Orthop Relat Res; 2017 Jul; 475(7):1819-1824. PubMed ID: 28050814
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of potential environmental contamination sources for the presence of multidrug-resistant bacteria linked to wound infections in combat casualties.
    Keen EF; Mende K; Yun HC; Aldous WK; Wallum TE; Guymon CH; Cole DW; Crouch HK; Griffith ME; Thompson BL; Rose JT; Murray CK
    Infect Control Hosp Epidemiol; 2012 Sep; 33(9):905-11. PubMed ID: 22869264
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sterile surgical helmet system in elective total hip and knee arthroplasty.
    Singh VK; Hussain S; Javed S; Singh I; Mulla R; Kalairajah Y
    J Orthop Surg (Hong Kong); 2011 Aug; 19(2):234-7. PubMed ID: 21857053
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]