These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 12447005)

  • 1. Assessment of gadobenate dimeglumine for magnetic resonance angiography: phase I studies.
    Knopp MV; Schoenberg SO; Rehm C; Floemer F; von Tengg-Kobligk H; Bock M; Hentrich HR
    Invest Radiol; 2002 Dec; 37(12):706-15. PubMed ID: 12447005
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Gadobenate dimeglumine (Gd-DTPA) vs gadopentetate dimeglumine (Gd-BOPTA) for contrast-enhanced magnetic resonance angiography (MRA): improvement in intravascular signal intensity and contrast to noise ratio.
    Pediconi F; Fraioli F; Catalano C; Napoli A; Danti M; Francone M; Venditti F; Nardis P; Passariello R
    Radiol Med; 2003; 106(1-2):87-93. PubMed ID: 12951555
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Low-dose gadobenate dimeglumine versus standard dose gadopentetate dimeglumine for contrast-enhanced magnetic resonance imaging of the liver: an intra-individual crossover comparison.
    Schneider G; Maas R; Schultze Kool L; Rummeny E; Gehl HB; Lodemann KP; Kirchin MA
    Invest Radiol; 2003 Feb; 38(2):85-94. PubMed ID: 12544071
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Contrast-enhanced MR angiography of the run-off vasculature: intraindividual comparison of gadobenate dimeglumine with gadopentetate dimeglumine.
    Knopp MV; Giesel FL; von Tengg-Kobligk H; Radeleff J; Requardt M; Kirchin MA; Hentrich HR
    J Magn Reson Imaging; 2003 Jun; 17(6):694-702. PubMed ID: 12766899
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Low-dose gadobenate dimeglumine versus standard-dose gadopentate dimeglumine for delayed contrast-enhanced cardiac magnetic resonance imaging.
    Balci NC; Inan N; Anik Y; Erturk MS; Ural D; Demirci A
    Acad Radiol; 2006 Jul; 13(7):833-9. PubMed ID: 16777557
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for enhanced MR imaging of brain and spine tumours in children.
    Colosimo C; Demaerel P; Tortori-Donati P; Christophe C; Van Buchem M; Högström B; Pirovano G; Shen N; Kirchin MA; Spinazzi A
    Pediatr Radiol; 2005 May; 35(5):501-10. PubMed ID: 15678342
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Low-dose contrast-enhanced magnetic resonance imaging of brain metastases at 3.0 T using high-relaxivity contrast agents.
    Huang B; Liang CH; Liu HJ; Wang GY; Zhang SX
    Acta Radiol; 2010 Feb; 51(1):78-84. PubMed ID: 19912078
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Low dose gadobenate dimeglumine for imaging of chronic myocardial infarction in comparison with standard dose gadopentetate dimeglumine.
    Bauner KU; Reiser MF; Huber AM
    Invest Radiol; 2009 Feb; 44(2):95-104. PubMed ID: 19077911
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intra-individual crossover comparison of gadobenate dimeglumine and gadopentetate dimeglumine for contrast-enhanced magnetic resonance angiography of the supraaortic vessels at 3 Tesla.
    Bueltmann E; Erb G; Kirchin MA; Klose U; Naegele T
    Invest Radiol; 2008 Oct; 43(10):695-702. PubMed ID: 18791411
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of intraaxial enhancing brain tumors on magnetic resonance imaging: intraindividual crossover comparison of gadobenate dimeglumine and gadopentetate dimeglumine for visualization and assessment, and implications for surgical intervention.
    Kuhn MJ; Picozzi P; Maldjian JA; Schmalfuss IM; Maravilla KR; Bowen BC; Wippold FJ; Runge VM; Knopp MV; Wolansky LJ; Gustafsson L; Essig M; Anzalone N
    J Neurosurg; 2007 Apr; 106(4):557-66. PubMed ID: 17432704
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Double-blind, efficacy evaluation of gadobenate dimeglumine, a gadolinium chelate with enhanced relaxivity, in malignant lesions of the brain.
    Runge VM; Parker JR; Donovan M
    Invest Radiol; 2002 May; 37(5):269-80. PubMed ID: 11979153
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Potential use of a diluted high-relaxivity gadolinium-based intra-articular contrast agent for magnetic resonance arthrography: an in-vitro study.
    Messina C; Albano D; Orlandi D; Chianca V; Corazza A; Ferrari F; Gitto S; Sconfienza LM
    BMC Med Imaging; 2019 Oct; 19(1):83. PubMed ID: 31653206
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Quantitative Lung Perfusion Imaging Using the Dual-Bolus Approach: Comparison of 3 Contrast Agents and Recommendation of Feasible Doses.
    Veldhoen S; Oechsner M; Fischer A; Weng AM; Kunz AS; Bley TA; Köstler H; Ritter CO
    Invest Radiol; 2016 Mar; 51(3):186-93. PubMed ID: 26606550
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Contrast-enhanced MR angiography: does a higher relaxivity MR contrast agent permit a reduction of the dose administered for routine vascular imaging applications?
    Xing X; Zeng X; Li X; Zhao Q; Kirchin MA; Pirovano G; Wang X; Li Y; Iezzi R; De Cobelli F
    Radiol Med; 2015 Feb; 120(2):239-50. PubMed ID: 25183340
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intraindividual in vivo comparison of gadolinium contrast agents for pharmacokinetic analysis using dynamic contrast enhanced magnetic resonance imaging.
    Liang J; Sammet S; Yang X; Jia G; Takayama Y; Knopp MV
    Invest Radiol; 2010 May; 45(5):233-44. PubMed ID: 20351653
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Multiphasic MR angiography as an intra-individual comparison between the contrast agents Gd-DTPA, Gd-BOPTA, and Gd-BT-DO3A].
    von Tengg-Kobligk H; Floemer F; Knopp MV
    Radiologe; 2003 Feb; 43(2):171-8. PubMed ID: 12624674
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intraindividual comparison of gadobenate dimeglumine and gadobutrol for cerebral magnetic resonance perfusion imaging at 1.5 T.
    Essig M; Lodemann KP; Le-Huu M; Brüning R; Kirchin M; Reith W
    Invest Radiol; 2006 Mar; 41(3):256-63. PubMed ID: 16481908
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Liver vessel enhancement by Gd-BOPTA and Gd-EOB-DTPA: a comparison in healthy volunteers.
    Brismar TB; Dahlstrom N; Edsborg N; Persson A; Smedby O; Albiin N
    Acta Radiol; 2009 Sep; 50(7):709-15. PubMed ID: 19701821
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intraindividual comparison of gadopentetate dimeglumine, gadobenate dimeglumine, and gadobutrol for pelvic 3D magnetic resonance angiography.
    Herborn CU; Lauenstein TC; Ruehm SG; Bosk S; Debatin JF; Goyen M
    Invest Radiol; 2003 Jan; 38(1):27-33. PubMed ID: 12496518
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Three-dimensional multiphase time-resolved low-dose contrast-enhanced magnetic resonance angiography using TWIST on a 32-channel coil at 3 T: a quantitative and qualitative comparison of a conventional gadolinium chelate with a high-relaxivity agent.
    Giesel FL; Runge V; Kirchin M; Mehndiratta A; Gerigk L; Corell B; von Gall C; Kauczor HU; Essig M
    J Comput Assist Tomogr; 2010; 34(5):678-83. PubMed ID: 20861769
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.