These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 12449226)

  • 1. Tube occlusion from the external ostium after implantation of an aqueous shunt.
    Bayer A; Wilson RR; Eagle RC
    Ophthalmic Surg Lasers; 2002; 33(6):493-6. PubMed ID: 12449226
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Molteno implant and refractory glaucoma. Evaluation of postoperative IOP control and complications with a modified surgical procedure].
    Hamard P; Loison-Dayma K; Kopel J; Hamard H; Baudouin C
    J Fr Ophtalmol; 2003 Jan; 26(1):15-23. PubMed ID: 12610405
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Otago Glaucoma Surgery Outcome Study: factors controlling capsule fibrosis around Molteno implants with histopathological correlation.
    Molteno AC; Fucik M; Dempster AG; Bevin TH
    Ophthalmology; 2003 Nov; 110(11):2198-206. PubMed ID: 14597530
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surgical revision of glaucoma shunt implants.
    Tsai JC; Grajewski AL; Parrish RK
    Ophthalmic Surg Lasers; 1999 Jan; 30(1):41-6. PubMed ID: 9923492
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the position and function of aqueous drainage implants with magnetic resonance imaging.
    Detorakis ET; Maris T; Papadaki E; Tsilimbaris MK; Karantanas AH; Pallikaris IG
    J Glaucoma; 2009 Aug; 18(6):453-9. PubMed ID: 19680053
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Aqueous shunts in glaucoma: a report by the American Academy of Ophthalmology.
    Minckler DS; Francis BA; Hodapp EA; Jampel HD; Lin SC; Samples JR; Smith SD; Singh K
    Ophthalmology; 2008 Jun; 115(6):1089-98. PubMed ID: 18519069
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Persistent leak after glaucoma aqueous shunt implantation.
    Robert MC; Hamel P; Blondeau P; Lesk MR
    J Glaucoma; 2013; 22(8):647-51. PubMed ID: 22576169
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tube extender for revision of glaucoma drainage implants.
    Sarkisian SR; Netland PA
    J Glaucoma; 2007; 16(7):637-9. PubMed ID: 18091184
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Aqueous shunts: single-plate Molteno vs ACTSEB.
    Kim DM; Lim KH
    Acta Ophthalmol Scand; 1995 Jun; 73(3):277-80. PubMed ID: 7493245
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Postoperative manipulation of the Krupin valve.
    Weiss HS
    Ophthalmic Surg Lasers; 1996 Feb; 27(2):151-3. PubMed ID: 8640441
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Long-term follow up of surgical repair of late bleb leaks after glaucoma filtering surgery.
    Al-Shahwan S; Al-Torbak AA; Al-Jadaan I; Omran M; Edward DP
    J Glaucoma; 2006 Oct; 15(5):432-6. PubMed ID: 16988607
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Internal glaucoma drainage device tube fenestration for uncontrolled postoperative intraocular pressure.
    Campbell RJ; Buys YM; McIlraith IP; Trope GE
    J Glaucoma; 2008 Sep; 17(6):494-6. PubMed ID: 18794687
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fibrin glue for preventing immediate postoperative hypotony following glaucoma drainage implant surgery.
    Välimäki J
    Acta Ophthalmol Scand; 2006 Jun; 84(3):372-4. PubMed ID: 16704700
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Complications following ex-press glaucoma shunt implantation.
    Stewart RM; Diamond JG; Ashmore ED; Ayyala RS
    Am J Ophthalmol; 2005 Aug; 140(2):340-1. PubMed ID: 16086969
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ahmed glaucoma valve implants in the pediatric population: the use of magnetic resonance imaging findings for surgical approach to reoperation.
    Pirouzian A; Scher C; O'Halloran H; Jockin Y
    J AAPOS; 2006 Aug; 10(4):340-4. PubMed ID: 16935235
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Placing the Molteno implant in a long scleral tunnel to prevent postoperative tube exposure.
    Ollila M; Falck A; Airaksinen PJ
    Acta Ophthalmol Scand; 2005 Jun; 83(3):302-5. PubMed ID: 15948781
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Glaucoma drainage system according to Molteno for therapy-resistant glaucoma--a two-stage surgical technique to avoid postoperative hypertension].
    Schmidt JC; Meyer CH; Hörle S
    Klin Monbl Augenheilkd; 2007 Aug; 224(8):641-6. PubMed ID: 17717780
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Level of vascular endothelial growth factor in aqueous humor and surgical results of ahmed glaucoma valve implantation in patients with neovascular glaucoma.
    Kim YG; Hong S; Lee CS; Kang SY; Seong GJ; Ma KT; Kim CY
    J Glaucoma; 2009 Aug; 18(6):443-7. PubMed ID: 19680051
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Replacement of Ahmed aqueous drainage devices in eyes with device-related complications.
    Smith M; Buys YM; Trope GE
    J Glaucoma; 2009 Aug; 18(6):484-7. PubMed ID: 19680058
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Implanted aqueous shunt devices for glaucoma surgery.
    Krupin T
    J Ophthalmic Nurs Technol; 1992; 11(1):23-5. PubMed ID: 1542125
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.