BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

389 related articles for article (PubMed ID: 12450290)

  • 1. Cerebrospinal fluid leaks following spinal surgery: use of fat grafts for prevention and repair. Technical note.
    Black P
    J Neurosurg; 2002 Mar; 96(2 Suppl):250-2. PubMed ID: 12450290
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cerebrospinal fluid leaks following spinal or posterior fossa surgery: use of fat grafts for prevention and repair.
    Black P
    Neurosurg Focus; 2000; 9(1):e4. PubMed ID: 16865811
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Novel dural closure technique using polyglactin acid sheet prevents cerebrospinal fluid leakage after spinal surgery.
    Sugawara T; Itoh Y; Hirano Y; Higashiyama N; Shimada Y; Kinouchi H; Mizoi K
    Neurosurgery; 2005 Oct; 57(4 Suppl):290-4; discussion 290-4. PubMed ID: 16234677
    [TBL] [Abstract][Full Text] [Related]  

  • 4. CSF-Related Complications After Intradural Spinal Tumor Surgery: Utility of an Autologous Fat Graft.
    Arnautovic KI; Kovacevic M
    Med Arch; 2016 Dec; 70(6):460-465. PubMed ID: 28210022
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Natura abhorret a vacuo--use of fibrin glue as a filler and sealant in neurosurgical "dead spaces". Technical note.
    Cappabianca P; Esposito F; Magro F; Cavallo LM; Solari D; Stella L; de Divitiis O
    Acta Neurochir (Wien); 2010 May; 152(5):897-904. PubMed ID: 20049488
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of tissue sealant patch (TachoSil) in the management of cerebrospinal fluid leaks after anterior cervical spine discectomy and fusion.
    Gazzeri R; Galarza M; Callovini G
    Br J Neurosurg; 2023 Oct; 37(5):1406-1409. PubMed ID: 33538190
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation and management of small dural tears in primary lumbar spinal decompression and discectomy surgery.
    Galarza M; Gazzeri R; Alfaro R; de la Rosa P; Arraez C; Piqueras C
    J Clin Neurosci; 2018 Apr; 50():177-182. PubMed ID: 29429786
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Surgical management of dural injuries and postoperative cerebrospinal fluid fistulas in spinal surgeries].
    Liu P; Zeng X; Liu F; Zhao J; Liu M; Fan W
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Jun; 22(6):715-8. PubMed ID: 18630571
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A new technique for dural suturing with fascia graft for cerebrospinal fluid leakage in transsphenoidal surgery.
    Ahn JY; Kim SH
    Neurosurgery; 2009 Dec; 65(6 Suppl):65-71; discussion 71-2. PubMed ID: 19935004
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Utility of nonpenetrating titanium clips for dural closure during spinal surgery to prevent postoperative cerebrospinal fluid leakage.
    Ito K; Aoyama T; Horiuchi T; Hongo K
    J Neurosurg Spine; 2015 Dec; 23(6):812-9. PubMed ID: 26315957
    [TBL] [Abstract][Full Text] [Related]  

  • 11. CSF complications following intradural spinal surgeries in children.
    Liu V; Gillis C; Cochrane D; Singhal A; Steinbok P
    Childs Nerv Syst; 2014 Feb; 30(2):299-305. PubMed ID: 24013216
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of fibrin glue on the prevention of persistent cerebral spinal fluid leakage after incidental durotomy during lumbar spinal surgery.
    Jankowitz BT; Atteberry DS; Gerszten PC; Karausky P; Cheng BC; Faught R; Welch WC
    Eur Spine J; 2009 Aug; 18(8):1169-74. PubMed ID: 19283413
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Direct suture technique of normal gland edge on the incised dura margin to repair the intraoperative cerebrospinal fluid leakage from the arachnoid recess during transsphenoidal pituitary tumor surgery.
    Kim EH; Roh TH; Park HH; Moon JH; Hong JB; Kim SH
    Neurosurgery; 2015 Mar; 11 Suppl 2():26-31; discussion 31. PubMed ID: 25584954
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dural suturing for repair of cerebrospinal fluid leak in transnasal transsphenoidal surgery.
    Nishioka H; Izawa H; Ikeda Y; Namatame H; Fukami S; Haraoka J
    Acta Neurochir (Wien); 2009 Nov; 151(11):1427-30. PubMed ID: 19499173
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The use of a novel perfusion-based cadaveric simulation model with cerebrospinal fluid reconstitution comparing dural repair techniques: a pilot study.
    Bakhsheshian J; Strickland BA; Patel NN; Jakoi AM; Minneti M; Zada G; Acosta FL; Hsieh PC; Wang JC; Liu JC; Pham MH
    Spine J; 2017 Sep; 17(9):1335-1341. PubMed ID: 28412565
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Polyethylene glycol (PEG) hydrogel dural sealant and collagen dural graft matrix in transsphenoidal pituitary surgery for prevention of postoperative cerebrospinal fluid leaks.
    Burkett CJ; Patel S; Tabor MH; Padhya T; Vale FL
    J Clin Neurosci; 2011 Nov; 18(11):1513-7. PubMed ID: 21868232
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A multicenter, single-blind, prospective randomized trial to evaluate the safety of a polyethylene glycol hydrogel (Duraseal Dural Sealant System) as a dural sealant in cranial surgery.
    Osbun JW; Ellenbogen RG; Chesnut RM; Chin LS; Connolly PJ; Cosgrove GR; Delashaw JB; Golfinos JG; Greenlee JD; Haines SJ; Jallo J; Muizelaar JP; Nanda A; Shaffrey M; Shah MV; Tew JM; van Loveren HR; Weinand ME; White JA; Wilberger JE
    World Neurosurg; 2012 Nov; 78(5):498-504. PubMed ID: 22381303
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A new technique of dural closure--experience with a vicryl mesh.
    Verheggen R; Schulte-Baumann WJ; Hahm G; Lang J; Freudenthaler S; Schaake T; Markakis E
    Acta Neurochir (Wien); 1997; 139(11):1074-9. PubMed ID: 9442223
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dural substitute with polyglycolic acid mesh and fibrin glue for dural repair: technical note and preliminary results.
    Shimada Y; Hongo M; Miyakoshi N; Sugawara T; Kasukawa Y; Ando S; Ishikawa Y; Itoi E
    J Orthop Sci; 2006 Oct; 11(5):454-8. PubMed ID: 17013732
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Polyethylene glycol hydrogel dural sealant may reduce incisional cerebrospinal fluid leak after posterior fossa surgery.
    Than KD; Baird CJ; Olivi A
    Neurosurgery; 2008 Jul; 63(1 Suppl 1):ONS182-6; discussion ONS186-7. PubMed ID: 18728598
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.