80 related articles for article (PubMed ID: 1245876)
1. Methods of correcting Anger camera deadtime losses.
Sorenson JA
J Nucl Med; 1976 Feb; 17(02):137-41. PubMed ID: 1245876
[TBL] [Abstract][Full Text] [Related]
2. The influence of true counting rate and the photopeak fraction of detected events on Anger camera deadtime.
Arnold JE; Johnston AS; Pinsky SM
J Nucl Med; 1974 Jun; 15(6):412-6. PubMed ID: 4829200
[No Abstract] [Full Text] [Related]
3. Image artifacts at high photon fluence rates in single-crystal NaI(T1) scintillation cameras.
Strand SE; Larsson I
J Nucl Med; 1978 Apr; 19(4):407-13. PubMed ID: 632930
[TBL] [Abstract][Full Text] [Related]
4. The effect of window fraction on the deadtime of Anger cameras: concise communication.
Wicks R; Blau M
J Nucl Med; 1977 Jul; 18(7):732-5. PubMed ID: 874153
[TBL] [Abstract][Full Text] [Related]
5. Comparing the performance of two gamma cameras under high counting rates: principles and practice.
Guldberg C; Rossing N
J Nucl Med; 1978 May; 19(5):545-52. PubMed ID: 641579
[TBL] [Abstract][Full Text] [Related]
6. Effect of the distribution of radioactive sources on deadtime loss in a single-crystal gamma camera.
Inoue Y; Ohtake T; Oritate T; Nishikawa J; Yoshikawa K; Sasaki Y
Radiat Med; 1998; 16(2):149-52. PubMed ID: 9650906
[TBL] [Abstract][Full Text] [Related]
7. Deadtime characteristics of Anger cameras.
Sorenson JA
J Nucl Med; 1975 Apr; 16(4):284-8. PubMed ID: 1113185
[TBL] [Abstract][Full Text] [Related]
8. Feasibility of a high-speed gamma-camera design using the high-yield-pileup-event-recovery method.
Wong WH; Li H; Uribe J; Baghaei H; Wang Y; Yokoyama S
J Nucl Med; 2001 Apr; 42(4):624-32. PubMed ID: 11337552
[TBL] [Abstract][Full Text] [Related]
9. Deadtime measurements in scintillation cameras under scatter conditions simulating quantitative nuclear cardiography.
Adams R; Hine GJ; Zimmerman CD
J Nucl Med; 1978 May; 19(5):538-44. PubMed ID: 641578
[TBL] [Abstract][Full Text] [Related]
10. Positron camera with extended counting rate capability.
Muehllehner G
J Nucl Med; 1975 Jul; 16(7):653-7. PubMed ID: 1151486
[TBL] [Abstract][Full Text] [Related]
11. Letter: Anger camera deadtime.
Huttig M
J Nucl Med; 1974 Jun; 15(6):468-9. PubMed ID: 4829214
[No Abstract] [Full Text] [Related]
12. The use of detective quantum efficiency (DQE) in evaluating the performance of gamma camera systems.
Starck SA; Båth M; Carlsson S
Phys Med Biol; 2005 Apr; 50(7):1601-9. PubMed ID: 15798346
[TBL] [Abstract][Full Text] [Related]
13. Effects of asymmetric photopeak windows on flood field uniformity and spatial resolution of scintillation cameras.
Graham LS; LaFontaine RL; Stein MA
J Nucl Med; 1986 May; 27(5):706-13. PubMed ID: 3712085
[TBL] [Abstract][Full Text] [Related]
14. Methods for calculating the deadtime of Anger camera systems.
Adams R; Zimmerman D
J Nucl Med; 1973 Jul; 14(7):496-8. PubMed ID: 4711265
[No Abstract] [Full Text] [Related]
15. Theoretical studies of image artifacts and counting losses for different photon fluence rates and pulse-height distributions in single-crystal NaI(T1) scintillation cameras.
Strand SE; Lamm IL
J Nucl Med; 1980 Mar; 21(3):264-75. PubMed ID: 7365519
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of a clinical scintillation camera with pulse tail extrapolation electronics.
Lewellen TK; Bice AN; Pollard KR; Zhu JB; Plunkett ME
J Nucl Med; 1989 Sep; 30(9):1554-8. PubMed ID: 2769408
[TBL] [Abstract][Full Text] [Related]
17. Correction for deadtime losses in a gamma camera/data analysis system.
Cranley K; Millar R; Bell TK
Eur J Nucl Med; 1980 Aug; 5(4):377-82. PubMed ID: 7398673
[TBL] [Abstract][Full Text] [Related]
18. Component resolution indices for scintillation camera systems.
Brookeman V
J Nucl Med; 1975 Mar; 16(3):228-30. PubMed ID: 1113172
[TBL] [Abstract][Full Text] [Related]
19. The channel ratio method of scatter correction for radionuclide image quantitation.
Pretorius PH; van Rensburg AJ; van Aswegen A; Lötter MG; Serfontein DE; Herbst CP
J Nucl Med; 1993 Feb; 34(2):330-5. PubMed ID: 8429357
[TBL] [Abstract][Full Text] [Related]
20. Absolute organ activity estimated by five different methods of background correction.
Buijs WC; Siegel JA; Boerman OC; Corstens FH
J Nucl Med; 1998 Dec; 39(12):2167-72. PubMed ID: 9867163
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]