112 related articles for article (PubMed ID: 1246152)
1. Cocking of a poppet-disc prosthesis in the aortic position. A cause of intermittent aortic regurgitation.
Hammer WJ; Hearne MJ; Roberts WC
J Thorac Cardiovasc Surg; 1976 Feb; 71(2):259-61. PubMed ID: 1246152
[TBL] [Abstract][Full Text] [Related]
2. Intermittent aortic regurgitation with tilting disc valves.
Aldrete V
J Thorac Cardiovasc Surg; 1984 Sep; 88(3):458-9. PubMed ID: 6471897
[No Abstract] [Full Text] [Related]
3. Poppet embolization in cloth-covered Silastic poppet valves.
Pluth JR; Danielson GK
Mayo Clin Proc; 1974 Nov; 49(11):811-4. PubMed ID: 4420364
[No Abstract] [Full Text] [Related]
4. Structural valve failure with every beat regurgitation observed using the Medtronic Advantage aortic valve.
Hansen L; Danne M; Hoffmann B; Riess FC
J Thorac Cardiovasc Surg; 2007 Nov; 134(5):1344-5. PubMed ID: 17976473
[No Abstract] [Full Text] [Related]
5. [Quadricuspid aortic valve: case reports].
Mathison M; Furuse A; Kotsuda H; Tanaka O; Chikada M
Kyobu Geka; 1990 May; 43(5):383-8. PubMed ID: 2374316
[TBL] [Abstract][Full Text] [Related]
6. [Stuck prosthetic aortic valve resulting in intermittent chest pain and ST depression: a case report].
Tanaka H; Horinouchi N; Hizukuri K; Fukuda Y; Kamikubo J; Kawaharada T; Tachibana H; Yamashita T; Yamashita M; Nakamura K
J Cardiol; 2000 Oct; 36(4):263-7. PubMed ID: 11079231
[TBL] [Abstract][Full Text] [Related]
7. Intermittent aortic regurgitation following aortic valve replacement.
Rumoroso JR; Arrizabalaga JI; Montes PM; Arriandiaga JR; Castellanos E; Barrenetxea JI
J Cardiovasc Surg (Torino); 1995 Oct; 36(5):443-5. PubMed ID: 8522559
[TBL] [Abstract][Full Text] [Related]
8. [Management of valve detachment following aortic valve replacement in aortic regurgitation due to aortitis].
Kawazoe K; Fujita T; Ohmori F
Rinsho Kyobu Geka; 1984 May; 4(3):372-5. PubMed ID: 6474061
[No Abstract] [Full Text] [Related]
9. [Aortic regurgitation due to aortic valve prolapse].
Shigenobu M; Aoki A; Kudo Y; Ohsumi S; Shichijo K; Senoo Y; Teramoto S
Kyobu Geka; 1987 Jun; 40(7):534-8. PubMed ID: 3626218
[No Abstract] [Full Text] [Related]
10. Valve replacement for aortic regurgitation: factors influencing results.
Friedlich AL; Curfman GD; Bland EF; Buckley MJ; Mundth ED; Austen WG
Trans Am Clin Climatol Assoc; 1976; 87():59-68. PubMed ID: 960425
[No Abstract] [Full Text] [Related]
11. Cyclic intermittent aortic regurgitation of a mechanical bileaflet aortic valve prosthesis: diagnosis and clinical implications.
Galli CA; Muratori M; Montorsi P; Barili F; Polvani G; Pepi M
J Am Soc Echocardiogr; 2007 Nov; 20(11):1315.e5-8. PubMed ID: 17600679
[TBL] [Abstract][Full Text] [Related]
12. Intermittent aortic regurgitation following aortic valve replacement with the Hall-Kaster prosthesis.
Antunes MJ; Colsen PR; Kinsley RH
J Thorac Cardiovasc Surg; 1982 Nov; 84(5):751-4. PubMed ID: 7132414
[TBL] [Abstract][Full Text] [Related]
13. Aortic valve replacement for aortic regurgitation due to Kawasaki disease. Report of two cases.
Fukunaga S; Egashira A; Arinaga K; Akasu I; Kai E; Higashi T; Kosuga K; Aoyagi S; Kazue T
J Heart Valve Dis; 1996 Mar; 5(2):231-4. PubMed ID: 8665019
[TBL] [Abstract][Full Text] [Related]
14. Tilting-disc versus bileaflet mechanical prostheses in the aortic position: a multicenter evaluation.
Vitale N; De Feo M; De Siena P; Cappabianca G; Onorati F; Gregorio R; Branzoli S; de Luca L; Schinosa T; Viganò M; Scardone M; Cotrufo M
J Heart Valve Dis; 2004 May; 13 Suppl 1():S27-34. PubMed ID: 15224997
[No Abstract] [Full Text] [Related]
15. [Aortic insufficiency on a Starr's valve].
Acar J; Raimbaux J; Lainée R; Antebi L; Grimberg D; Luxereau P
Arch Mal Coeur Vaiss; 1973 Jan; 66(1):113-21. PubMed ID: 4198572
[No Abstract] [Full Text] [Related]
16. The significance of intermittent regurgitation in aortic valve prostheses.
Allen P; Robertson R
J Thorac Cardiovasc Surg; 1967 Oct; 54(4):549-56. PubMed ID: 6051442
[No Abstract] [Full Text] [Related]
17. [Bicuspid aortic valve with sudden onset of aortic insufficiency due to rare causes: report of two cases].
Hamada Y; Iijima T; Yoshida I; Tsuda K; Ishikawa S; Yanagisawa H; Ohtaki A; Ohtani Y; Takahashi T; Morishita Y
Kyobu Geka; 1992 Jun; 45(6):519-21. PubMed ID: 1602681
[TBL] [Abstract][Full Text] [Related]
18. Aortic valve replacement with the Björk-Shiley tilting disc valve prosthesis.
Björk VO
Br Heart J; 1971; 33(Suppl):Suppl:42-6. PubMed ID: 5572645
[No Abstract] [Full Text] [Related]
19. Sticking aortic valve. A complication of fabric-covered ball-valve prosthesis.
Mullin MJ; Muth WF; McNamara JJ
J Thorac Cardiovasc Surg; 1972 Feb; 63(2):215-7. PubMed ID: 5009732
[No Abstract] [Full Text] [Related]
20. Intermittent acute aortic valve regurgitation: a case report of a prosthetic valve dysfunction.
Karagiannis SE; Karatasakis G; Spargias K; Louka L; Poldermans D; Cokkinos DV
Eur J Echocardiogr; 2008 Mar; 9(2):291-3. PubMed ID: 17097353
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]