BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 12466867)

  • 21. Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw.
    Haynes RC; Pöll RG; Miles AW; Weston RB
    Injury; 1997; 28(5-6):337-41. PubMed ID: 9764228
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Correct placement of the screw or nail in trochanteric fractures. Effect of the initial placement in the migration.
    Galanakis IA; Steriopoulos KA; Dretakis EK
    Clin Orthop Relat Res; 1995 Apr; (313):206-13. PubMed ID: 7641482
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Biomechanical stability of different fixation constructs for ORIF of radial neck fractures.
    Capo JT; Svach D; Ahsgar J; Orillaza NS; Sabatino CT
    Orthopedics; 2008 Oct; 31(10):. PubMed ID: 19226014
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Biomechanical characterisation of osteosyntheses for proximal femur fractures: helical blade versus screw.
    Al-Munajjed AA; Hammer J; Mayr E; Nerlich M; Lenich A
    Stud Health Technol Inform; 2008; 133():1-10. PubMed ID: 18376008
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Intertrochanteric fracture: Association between the coronal position of the lag screw and stress distribution.
    Liang C; Peng R; Jiang N; Xie G; Wang L; Yu B
    Asian J Surg; 2018 May; 41(3):241-249. PubMed ID: 28366494
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Torsion and bending analysis of internal fixation techniques for femoral neck fractures: the role of implant design and bone density.
    Swiontkowski MF; Harrington RM; Keller TS; Van Patten PK
    J Orthop Res; 1987; 5(3):433-44. PubMed ID: 3625366
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Suture versus screw fixation of displaced tibial eminence fractures: a biomechanical comparison.
    Bong MR; Romero A; Kubiak E; Iesaka K; Heywood CS; Kummer F; Rosen J; Jazrawi L
    Arthroscopy; 2005 Oct; 21(10):1172-6. PubMed ID: 16226643
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Sliding of two lag screw designs in a highly comminuted fracture model.
    Kummer FJ; Schwarzkopf R; Takemoto RC; Egol KA
    Bull NYU Hosp Jt Dis; 2011; 69(4):289-91. PubMed ID: 22196383
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Biomechanical analysis of a novel femoral neck locking plate for treatment of vertical shear Pauwel's type C femoral neck fractures.
    Nowotarski PJ; Ervin B; Weatherby B; Pettit J; Goulet R; Norris B
    Injury; 2012 Jun; 43(6):802-6. PubMed ID: 22019259
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical comparison of the sliding hip screw and the dome plunger. Effects of material and fixation design.
    Choueka J; Koval KJ; Kummer FJ; Crawford G; Zuckerman JD
    J Bone Joint Surg Br; 1995 Mar; 77(2):277-83. PubMed ID: 7706347
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Torsional strength of double- versus single-screw fixation in a pig model of unstable slipped capital femoral epiphysis.
    Snyder RR; Williams JL; Schmidt TL; Salsbury TL
    J Pediatr Orthop; 2006; 26(3):295-9. PubMed ID: 16670538
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Increasing bone screw anchoring in the femur head by cement administration via the implant--a biomechanical study].
    Kramer A; Angst M; Gasser B; Ganz R
    Z Orthop Ihre Grenzgeb; 2000; 138(5):464-9. PubMed ID: 11084750
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Helical blade vs telescoping lag screw for intertrochanteric fracture fixation.
    Schwarzkopf R; Takemoto RC; Kummer FJ; Egol KA
    Am J Orthop (Belle Mead NJ); 2011 Sep; 40(9):452-6. PubMed ID: 22022674
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Locking plates increase the strength of dynamic hip screws.
    Jewell DP; Gheduzzi S; Mitchell MS; Miles AW
    Injury; 2008 Feb; 39(2):209-12. PubMed ID: 17880976
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Biomechanical comparison of polyaxial-type locking plates and a fixed-angle locking plate for internal fixation of distal femur fractures.
    Otto RJ; Moed BR; Bledsoe JG
    J Orthop Trauma; 2009 Oct; 23(9):645-52. PubMed ID: 19897986
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A short plate compression screw with diagonal bolts--a biomechanical evaluation performed experimentally and by numerical computation.
    Peleg E; Mosheiff R; Liebergall M; Mattan Y
    Clin Biomech (Bristol, Avon); 2006 Nov; 21(9):963-8. PubMed ID: 16893595
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Does a trochanteric lag screw improve fixation of vertically oriented femoral neck fractures? A biomechanical analysis in cadaveric bone.
    Hawks MA; Kim H; Strauss JE; Oliphant BW; Golden RD; Hsieh AH; Nascone JW; O'Toole RV
    Clin Biomech (Bristol, Avon); 2013 Oct; 28(8):886-91. PubMed ID: 24050951
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biomechanical analysis of the percutaneous compression plate and sliding hip screw in intracapsular hip fractures: experimental assessment using synthetic and cadaver bones.
    Brandt E; Verdonschot N; van Vugt A; van Kampen A
    Injury; 2006 Oct; 37(10):979-83. PubMed ID: 16934259
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Treatment of early cut-out of a lag screw using a trochanter supporting plate: 11 consecutive patients with unstable intertrochanteric fractures.
    Lee PC; Yu SW; Hsieh PH; Chuang TY; Tai CL; Shih CH
    Arch Orthop Trauma Surg; 2004 Mar; 124(2):119-22. PubMed ID: 14652777
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Hip screw migration testing: first results for hip screws and helical blades utilizing a new oscillating test method.
    Born CT; Karich B; Bauer C; von Oldenburg G; Augat P
    J Orthop Res; 2011 May; 29(5):760-6. PubMed ID: 20830738
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.