These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 12467853)

  • 1. Online automated detection of cerebral embolic signals from a variety of embolic sources.
    Cullinane M; Kaposzta Z; Reihill S; Markus HS
    Ultrasound Med Biol; 2002 Oct; 28(10):1271-7. PubMed ID: 12467853
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of new online automated embolic signal detection algorithm, including comparison with panel of international experts.
    Cullinane M; Reid G; Dittrich R; Kaposzta Z; Ackerstaff R; Babikian V; Droste DW; Grossett D; Siebler M; Valton L; Markus HS
    Stroke; 2000 Jun; 31(6):1335-41. PubMed ID: 10835453
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Online automated detection of cerebral embolic signals using a wavelet-based system.
    Marvasti S; Gillies D; Marvasti F; Markus HS
    Ultrasound Med Biol; 2004 May; 30(5):647-53. PubMed ID: 15183231
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved automated detection of embolic signals using a novel frequency filtering approach.
    Markus H; Cullinane M; Reid G
    Stroke; 1999 Aug; 30(8):1610-5. PubMed ID: 10436109
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Long-term ambulatory monitoring for cerebral emboli using transcranial Doppler ultrasound.
    Mackinnon AD; Aaslid R; Markus HS
    Stroke; 2004 Jan; 35(1):73-8. PubMed ID: 14684774
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Doppler embolic signals in cerebrovascular disease and prediction of stroke risk: a systematic review and meta-analysis.
    King A; Markus HS
    Stroke; 2009 Dec; 40(12):3711-7. PubMed ID: 19850894
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Real-time identification and archiving of micro-embolic Doppler signals using a knowledge-based DSP system.
    Fan L; Evans DH; Naylor AR; Tortoli P
    Med Biol Eng Comput; 2004 Mar; 42(2):193-200. PubMed ID: 15125149
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Asymptomatic Carotid Emboli Study: study design and baseline results.
    ACES Investigators
    Int J Stroke; 2009 Oct; 4(5):398-405. PubMed ID: 19765130
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transcranial Doppler assessment of cerebral embolic disorders.
    Gorman M
    Prog Cardiovasc Dis; 2000; 43(2):135-50. PubMed ID: 11014330
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characteristics of Doppler embolic signals observed following carotid endarterectomy.
    Chung EM; Fan L; Naylor AR; Evans DH
    Ultrasound Med Biol; 2006 Jul; 32(7):1011-23. PubMed ID: 16829315
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of clinical environment on embolus detection: a comparison of automated and manual detection of Doppler embolic signals.
    Chung EM; Fan L; Naylor AR; Evans DH
    Cerebrovasc Dis; 2007; 23(2-3):169-74. PubMed ID: 17124399
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dextran reduces embolic signals after carotid endarterectomy.
    Levi CR; Stork JL; Chambers BR; Abbott AL; Cameron HM; Peeters A; Royle JP; Roberts AK; Fell G; Hoare MC; Chan AT; Donnan GA
    Ann Neurol; 2001 Oct; 50(4):544-7. PubMed ID: 11601508
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automatic detection of emboli in the TCD RF signal using principal component analysis.
    Cowe J; Evans DH
    Ultrasound Med Biol; 2006 Dec; 32(12):1853-67. PubMed ID: 17169698
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Embolic Doppler ultrasound signal detection using continuous wavelet transform to detect multiple vascular emboli.
    Ng HS; Hao Q; Leung T; Lawrence Wong KS; Nygaard H; Hasenkam JM; Johansen P
    J Neuroimaging; 2008 Oct; 18(4):388-95. PubMed ID: 18304032
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of 'on-treatment platelet reactivity' and relationship with cerebral micro-embolic signals in asymptomatic and symptomatic carotid stenosis.
    Kinsella JA; Oliver Tobin W; Tierney S; Feeley TM; Egan B; Coughlan T; Ronan Collins D; O'Neill D; Harbison JA; Doherty CP; Madhavan P; Moore DJ; O'Neill SM; Colgan MP; Saqqur M; Murphy RP; Moran N; Hamilton G; McCabe DJH
    J Neurol Sci; 2017 May; 376():133-139. PubMed ID: 28431600
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transcranial Doppler Ultrasound Detection of Microemboli as a Predictor of Cerebral Events in Patients with Symptomatic and Asymptomatic Carotid Disease: A Systematic Review and Meta-Analysis.
    Best LM; Webb AC; Gurusamy KS; Cheng SF; Richards T
    Eur J Vasc Endovasc Surg; 2016 Nov; 52(5):565-580. PubMed ID: 27397116
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transcranial Doppler Ultrasound in the Current Era of Carotid Artery Stenting.
    Spacek M; Sorrell VL; Veselka J
    Ultraschall Med; 2015 Aug; 36(4):337-41. PubMed ID: 24963921
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Feasibility and reliability of on-line automated microemboli detection after carotid endarterectomy. A transcranial Doppler study.
    Munts AG; Mess WH; Bruggemans EF; Walda L; Ackerstaff RG
    Eur J Vasc Endovasc Surg; 2003 Mar; 25(3):262-6. PubMed ID: 12623339
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of a 1 MHz transducer for transcranial Doppler ultrasound including embolic signal detection.
    Cullinane M; Markus HS
    Ultrasound Med Biol; 2001 Jun; 27(6):795-800. PubMed ID: 11516539
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reduced frequency of embolic signals in severe carotid stenosis with poststenotic flow velocity reduction.
    Goertler M; Blaser T; Guhr S; Lotze H; Heisinger J; Kropf S; Wallesch CW
    Cerebrovasc Dis; 2005; 19(4):229-33. PubMed ID: 15703467
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.