479 related articles for article (PubMed ID: 12472408)
1. Development of a new hollow fiber silicone membrane oxygenator for ECMO: the recent progress.
Kawahito S; Motomura T; Glueck J; Nosé Y
Ann Thorac Cardiovasc Surg; 2002 Oct; 8(5):268-74. PubMed ID: 12472408
[TBL] [Abstract][Full Text] [Related]
2. Feasibility of a new hollow fiber silicone membrane oxygenator for long-term ECMO application.
Kawahito S; Maeda T; Motomura T; Takano T; Nonaka K; Linneweber J; Ichikawa S; Ishitoya H; Hanazaki K; Glueck J; Sato K; Nosé Y
J Med Invest; 2002 Aug; 49(3-4):156-62. PubMed ID: 12323005
[TBL] [Abstract][Full Text] [Related]
3. Development of a new silicone membrane oxygenator for ECMO.
Nakata K; Maeda T; Murabayashi S; Yoshikawa M; Takano T; Iwasaki A; Nonaka K; Linneweber J; Kawahito S; Glueck J; Sato K; Kuwana J; Nosé Y
Ann Thorac Cardiovasc Surg; 2000 Dec; 6(6):373-7. PubMed ID: 11173351
[TBL] [Abstract][Full Text] [Related]
4. Preclinical evaluation of a new hollow fiber silicone membrane oxygenator for pediatric cardiopulmonary bypass: ex-vivo study.
Kawahito S; Haraguchi S; Maeda T; Motomura T; Takano T; Nonaka K; Linneweber J; Ichikawa S; Kawamura M; Ishitoya H; Glueck J; Sato K; Nosé Y
Ann Thorac Cardiovasc Surg; 2002 Feb; 8(1):7-11. PubMed ID: 11916436
[TBL] [Abstract][Full Text] [Related]
5. Development of the oxygenator: past, present, and future.
Iwahashi H; Yuri K; Nosé Y
J Artif Organs; 2004; 7(3):111-20. PubMed ID: 15558331
[TBL] [Abstract][Full Text] [Related]
6. Development of a membrane oxygenator for ECMO using a novel fine silicone hollow fiber.
Funakubo A; Higami T; Sakuma I; Fukui Y; Kawamura T; Sato K; Sueoka A; Nosé Y
ASAIO J; 1996; 42(5):M837-40. PubMed ID: 8945001
[TBL] [Abstract][Full Text] [Related]
7. Introduction of a new oxygenator including a tight fiber for long-term ECMO in infants.
Kind K; Reiss N; Knobl HJ; Blanz U; Körfer R
ASAIO J; 2006; 52(2):217-8. PubMed ID: 16557113
[TBL] [Abstract][Full Text] [Related]
8. Description of a flow optimized oxygenator with integrated pulsatile pump.
Borchardt R; Schlanstein P; Arens J; Graefe R; Schreiber F; Schmitz-Rode T; Steinseifer U
Artif Organs; 2010 Nov; 34(11):904-10. PubMed ID: 21092033
[TBL] [Abstract][Full Text] [Related]
9. [Present status and future observation of membrane oxygenator].
Teramoto S
Kyobu Geka; 1989 Jul; 42(8 Suppl):665-9. PubMed ID: 2691748
[TBL] [Abstract][Full Text] [Related]
10. Performance of a MedArray silicone hollow fiber oxygenator.
LaFayette NG; Schewe RE; Montoya JP; Cook KE
ASAIO J; 2009; 55(4):382-7. PubMed ID: 19381081
[TBL] [Abstract][Full Text] [Related]
11. Development of a silicone hollow fiber membrane oxygenator for ECMO application.
Yamane S; Ohashi Y; Sueoka A; Sato K; Kuwana J; Nosé Y
ASAIO J; 1998; 44(5):M384-7. PubMed ID: 9804456
[TBL] [Abstract][Full Text] [Related]
12. Development of silicone rubber hollow fiber membrane oxygenator for ECMO.
Motomura T; Maeda T; Kawahito S; Matsui T; Ichikawa S; Ishitoya H; Kawamura M; Shinohara T; Sato K; Kawaguchi Y; Taylor D; Oestmann D; Glueck J; Nosé Y
Artif Organs; 2003 Nov; 27(11):1050-3. PubMed ID: 14616524
[TBL] [Abstract][Full Text] [Related]
13. [The development of research on membrane oxgenator application].
Wang L; Chen H; Wang K
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Feb; 24(1):240-4. PubMed ID: 17333931
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of a preprimed microporous hollow-fiber membrane for rapid response neonatal extracorporeal membrane oxygenation.
Walczak R; Lawson DS; Kaemmer D; McRobb C; McDermott P; Smigla G; Shearer I; Lodge A; Jaggers J
Perfusion; 2005 Sep; 20(5):269-75. PubMed ID: 16231623
[TBL] [Abstract][Full Text] [Related]
15. Development of a compact extracorporeal membrane oxygenation (ECMO) system.
Funakubo A; Sakuma I; Fukui Y; Kawamura T
Artif Organs; 1991 Feb; 15(1):56-9. PubMed ID: 1998492
[TBL] [Abstract][Full Text] [Related]
16. [Studies on ECMO. (III)--Study on pumpless A-V ECMO].
Tanaka Y
Masui; 1990 Feb; 39(2):154-61. PubMed ID: 2325249
[TBL] [Abstract][Full Text] [Related]
17. Retrospective analysis comparing hollow fiber and silicone membrane oxygenators for neonates on ECMO.
Mejak B; Giacomuzzi C; Heller E; You X; Ungerleider R; Shen I
J Extra Corpor Technol; 2007 Jun; 39(2):71-4. PubMed ID: 17672186
[TBL] [Abstract][Full Text] [Related]
18. Clinical evaluation of a silicone coated hollow fiber oxygenator.
Shimono T; Shomura Y; Tani K; Shimamoto A; Hioki I; Tokui T; Onoda K; Takao M; Shimpo H; Yada I
ASAIO J; 1997; 43(5):M735-9. PubMed ID: 9360143
[TBL] [Abstract][Full Text] [Related]
19. DIDECMO: a new polymethylpentene oxygenator for pediatric extracorporeal membrane oxygenation.
Agati S; Ciccarello G; Fachile N; Scappatura RM; Grasso D; Salvo D; Undar A; Mignosa C
ASAIO J; 2006; 52(5):509-12. PubMed ID: 16966847
[TBL] [Abstract][Full Text] [Related]
20. Extracorporeal membrane oxygenation with a poly-methylpentene oxygenator (Quadrox D). The experience of a single Italian centre in adult patients with refractory cardiogenic shock.
Formica F; Avalli L; Martino A; Maggioni E; Muratore M; Ferro O; Pesenti A; Paolini G
ASAIO J; 2008; 54(1):89-94. PubMed ID: 18204321
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]