These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 12474215)

  • 1. Development, validation and analytical error function of two chromatographic methods with fluorimetric detection for the determination of bisoprolol and metoprolol in human plasma.
    Braza AJ; Modamio P; Lastra CF; Mariño EL
    Biomed Chromatogr; 2002 Dec; 16(8):517-22. PubMed ID: 12474215
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A high throughput and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the estimation of bisoprolol in human plasma using multiplexing technique.
    Bhatt J; Subbaiah G; Kambli S; Shah B; Patel M; Saxena A; Baliga A; Nigam S; Parekh H; Yadav G
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jun; 852(1-2):374-81. PubMed ID: 17324642
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Liquid chromatographic-electrospray tandem mass spectrometric determination of bisoprolol in human plasma.
    Liu M; Zhang D; Sun Y; Wang Y; Liu Z; Gu J
    Biomed Chromatogr; 2007 May; 21(5):508-13. PubMed ID: 17294507
    [TBL] [Abstract][Full Text] [Related]  

  • 4. LC-ESI-MS method for the determination of bisoprolol in human plasma.
    Ding L; Zhou X; Guo X; Song Q; He J; Xu G
    J Pharm Biomed Anal; 2007 Jun; 44(2):520-5. PubMed ID: 17418521
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development and validation of a stereoselective liquid chromatography-tandem mass spectrometry assay for quantification of S- and R-metoprolol in human plasma.
    Jensen BP; Sharp CF; Gardiner SJ; Begg EJ
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Apr; 865(1-2):48-54. PubMed ID: 18321797
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of saquinavir and ritonavir in human plasma by reversed-phase high-performance liquid chromatography and the analytical error function.
    Albert V; Modamio P; Lastra CF; Mariño EL
    J Pharm Biomed Anal; 2004 Nov; 36(4):835-40. PubMed ID: 15533677
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An HPLC method for the determination of bisoprolol in human plasma and its application to a pharmacokinetic study.
    Ulu ST; Aydoğmuş Z
    J Chromatogr Sci; 2012 Aug; 50(7):615-9. PubMed ID: 22553280
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous determination of thirteen beta-blockers and one metabolite by gradient high-performance liquid chromatography with photodiode-array UV detection.
    Delamoye M; Duverneuil C; Paraire F; de Mazancourt P; Alvarez JC
    Forensic Sci Int; 2004 Apr; 141(1):23-31. PubMed ID: 15066710
    [TBL] [Abstract][Full Text] [Related]  

  • 9. HPLC quantification of metoprolol with solid-phase extraction for the drug monitoring of pediatric patients.
    Albers S; Elshoff JP; Völker C; Richter A; Läer S
    Biomed Chromatogr; 2005 Apr; 19(3):202-7. PubMed ID: 15484221
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of metoprolol in human plasma and urine by high-performance liquid chromatography with fluorescence detection.
    Yilmaz B; Asci A; Arslan S
    J Sep Sci; 2010 Jul; 33(13):1904-8. PubMed ID: 20512810
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Gas chromatography-mass spectrometry method for determination of metoprolol in the patients with hypertension.
    Yilmaz B; Arslan S; Akba V
    Talanta; 2009 Nov; 80(1):346-51. PubMed ID: 19782235
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Method development and validation of repaglinide in human plasma by HPLC and its application in pharmacokinetic studies.
    Ruzilawati AB; Wahab MS; Imran A; Ismail Z; Gan SH
    J Pharm Biomed Anal; 2007 Apr; 43(5):1831-5. PubMed ID: 17240100
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of metoprolol, and its four metabolites in dog plasma.
    Fang J; Semple HA; Song J
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Sep; 809(1):9-14. PubMed ID: 15282087
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hydrophilic interaction liquid chromatographic tandem mass spectrometric determination of atenolol in human plasma.
    Li W; Li Y; Francisco DT; Naidong W
    Biomed Chromatogr; 2005 Jun; 19(5):385-93. PubMed ID: 15651086
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of the new beta-blocker bisoprolol and of metoprolol, atenolol and propranolol in plasma and urine by high-performance liquid chromatography.
    Bühring KU; Garbe A
    J Chromatogr; 1986 Oct; 382():215-24. PubMed ID: 2878004
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development and validation of a reversed-phase HPLC method for determination of nitrendipine in rat plasma: application to pharmacokinetic studies.
    Venishetty VK; Durairaj C; Sistla R; Yamsani MR; Diwan PV
    Biomed Chromatogr; 2007 Apr; 21(4):363-8. PubMed ID: 17236247
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High performance liquid chromatographic method for the determination of sumatriptan with fluorescence detection in human plasma.
    Ge Z; Tessier E; Neirinck L; Zhu Z
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Jul; 806(2):299-303. PubMed ID: 15171943
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simultaneous determination of bisoprolol and hydrochlorothiazide in human plasma by HPLC coupled with tandem mass spectrometry.
    Tutunji MF; Ibrahim HM; Khabbas MH; Tutunji LF
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Jun; 877(16-17):1689-97. PubMed ID: 19427275
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Stereoselective metabolism of metoprolol: enantioselectivity of alpha-hydroxymetoprolol in plasma and urine.
    Cerqueira PM; Cesarino EJ; Bertucci C; Bonato PS; Lanchote VL
    Chirality; 2003 Jun; 15(6):542-9. PubMed ID: 12774293
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simple and rapid method determination for metformin in human plasma using high performance liquid chromatography tandem mass spectrometry: application to pharmacokinetic studies.
    Marques MA; Soares Ade S; Pinto OW; Barroso PT; Pinto DP; Ferreira-Filho M; Werneck-Barroso E
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jun; 852(1-2):308-16. PubMed ID: 17331818
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.