102 related articles for article (PubMed ID: 12476944)
1. Highly specific, simple and rapid method for the determination of malondialdehyde in blood using high-performance liquid chromatography.
Roman K; Vladimíra M; Alexander C
Clin Chem Lab Med; 2002 Oct; 40(10):1032-5. PubMed ID: 12476944
[TBL] [Abstract][Full Text] [Related]
2. A simple, rapid, highly sensitive and reproducible quantification method for plasma malondialdehyde by high-performance liquid chromatography.
Fukunaga K; Yoshida M; Nakazono N
Biomed Chromatogr; 1998; 12(5):300-3. PubMed ID: 9787903
[TBL] [Abstract][Full Text] [Related]
3. Simultaneous determination of malondialdehyde and ofloxacin in plasma using an isocratic high-performance liquid chromatography/fluorescence detection system.
Cheng GW; Wu HL; Huang YL
Anal Chim Acta; 2008 Jun; 616(2):230-4. PubMed ID: 18482608
[TBL] [Abstract][Full Text] [Related]
4. Improvement in the high-performance liquid chromatography malondialdehyde level determination in normal human plasma.
Volpi N; Tarugi P
J Chromatogr B Biomed Sci Appl; 1998 Aug; 713(2):433-7. PubMed ID: 9746260
[TBL] [Abstract][Full Text] [Related]
5. Rapid quantification of malondialdehyde in plasma by high performance liquid chromatography-visible detection.
Grotto D; Santa Maria LD; Boeira S; Valentini J; Charão MF; Moro AM; Nascimento PC; Pomblum VJ; Garcia SC
J Pharm Biomed Anal; 2007 Jan; 43(2):619-24. PubMed ID: 16949242
[TBL] [Abstract][Full Text] [Related]
6. High-performance liquid chromatographic determination of plasma malondialdehyde level without a solvent extraction procedure.
Fukunaga K; Takama K; Suzuki T
Anal Biochem; 1995 Sep; 230(1):20-3. PubMed ID: 8585624
[TBL] [Abstract][Full Text] [Related]
7. High-performance liquid chromatographic detection of lipid peroxidation in human seminal plasma and its application to male infertility.
Li K; Shang X; Chen Y
Clin Chim Acta; 2004 Aug; 346(2):199-203. PubMed ID: 15256321
[TBL] [Abstract][Full Text] [Related]
8. High performance liquid chromatographic method for the determination of cetirizine and ambroxol in human plasma and urine--a boxcar approach.
Dharuman J; Vasudhevan M; Ajithlal T
J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Sep; 879(25):2624-31. PubMed ID: 21840269
[TBL] [Abstract][Full Text] [Related]
9. Total plasma malondialdehyde levels in 16 Taiwanese college students determined by various thiobarbituric acid tests and an improved high-performance liquid chromatography-based method.
Hong YL; Yeh SL; Chang CY; Hu ML
Clin Biochem; 2000 Nov; 33(8):619-25. PubMed ID: 11166008
[TBL] [Abstract][Full Text] [Related]
10. Rapid, fluorimetric-liquid chromatographic determination of malondialdehyde in biological samples.
Agarwal R; Chase SD
J Chromatogr B Analyt Technol Biomed Life Sci; 2002 Jul; 775(1):121-6. PubMed ID: 12101069
[TBL] [Abstract][Full Text] [Related]
11. A rapid high performance liquid chromatographic determination of methyldopa in human serum with fluorescence detection and alumina extraction: application to a bioequivalence study.
Bahrami G; Kiani A; Mirzaeei S
J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Mar; 832(2):197-201. PubMed ID: 16448867
[TBL] [Abstract][Full Text] [Related]
12. Increased plasma malondialdehyde levels in glomerular disease as determined by a fully validated HPLC method.
Templar J; Kon SP; Milligan TP; Newman DJ; Raftery MJ
Nephrol Dial Transplant; 1999 Apr; 14(4):946-51. PubMed ID: 10328476
[TBL] [Abstract][Full Text] [Related]
13. Automated on-line microdialysis sampling coupled with high-performance liquid chromatography for simultaneous determination of malondialdehyde and ofloxacin in whole blood.
Cheng GW; Wu HL; Huang YL
Talanta; 2009 Sep; 79(4):1071-5. PubMed ID: 19615511
[TBL] [Abstract][Full Text] [Related]
14. [Determination of lipid peroxidation in human seminal plasma by high performance liquid chromatography and its diagnostic value of male infertility].
Li K; Shang X; Chen Y
Se Pu; 2004 Jul; 22(4):412-5. PubMed ID: 15709422
[TBL] [Abstract][Full Text] [Related]
15. An optimized and validated RP-HPLC/UV detection method for simultaneous determination of all-trans-retinol (vitamin A) and alpha-tocopherol (vitamin E) in human serum: comparison of different particulate reversed-phase HPLC columns.
Khan A; Khan MI; Iqbal Z; Shah Y; Ahmad L; Watson DG
J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Sep; 878(25):2339-47. PubMed ID: 20696624
[TBL] [Abstract][Full Text] [Related]
16. A chemiluminescence method to detect malondialdehyde in plasma and urine.
Zhang G; Tang Y; Shi X; Gao R; Sun Y; Du W; Fu Q
Anal Biochem; 2013 Dec; 443(1):16-21. PubMed ID: 23973627
[TBL] [Abstract][Full Text] [Related]
17. Determination of losartan, telmisartan, and valsartan by direct injection of human urine into a column-switching liquid chromatographic system with fluorescence detection.
del Rosario Brunetto M; Contreras Y; Clavijo S; Torres D; Delgado Y; Ovalles F; Ayala C; Gallignani M; Estela JM; Martin VC
J Pharm Biomed Anal; 2009 Sep; 50(2):194-9. PubMed ID: 19446420
[TBL] [Abstract][Full Text] [Related]
18. A novel HPLC method for the measurement of thiobarbituric acid reactive substances (TBARS). A comparison with a commercially available kit.
Seljeskog E; Hervig T; Mansoor MA
Clin Biochem; 2006 Sep; 39(9):947-54. PubMed ID: 16781699
[TBL] [Abstract][Full Text] [Related]
19. New method for HPLC separation and fluorescence detection of malonaldehyde in normal human plasma.
Mao J; Zhang H; Luo J; Li L; Zhao R; Zhang R; Liu G
J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Feb; 832(1):103-8. PubMed ID: 16439188
[TBL] [Abstract][Full Text] [Related]
20. Very rapid quantification of malondialdehyde (MDA) in rat brain exposed to lead, aluminium and phenolic antioxidants by high-performance liquid chromatography-fluorescence detection.
Candan N; Tuzmen N
Neurotoxicology; 2008 Jul; 29(4):708-13. PubMed ID: 18550174
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]