These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 12476986)

  • 1. Comparative evaluation of Kodak EDR2 and XV2 films for verification of intensity modulated radiation therapy.
    Dogan N; Leybovich LB; Sethi A
    Phys Med Biol; 2002 Nov; 47(22):4121-30. PubMed ID: 12476986
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dosimetric accuracy of Kodak EDR2 film for IMRT verifications.
    Childress NL; Salehpour M; Dong L; Bloch C; White RA; Rosen II
    Med Phys; 2005 Feb; 32(2):539-48. PubMed ID: 15789600
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance.
    Olch AJ
    Med Phys; 2002 Sep; 29(9):2159-68. PubMed ID: 12349938
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator.
    Zhu XR; Jursinic PA; Grimm DF; Lopez F; Rownd JJ; Gillin MT
    Med Phys; 2002 Aug; 29(8):1687-92. PubMed ID: 12201414
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimal sensitometric curves of Kodak EDR2 film for dynamic intensity modulated radiation therapy verification.
    Suriyapee S; Pitaxtarnin N; Oonsiri S; Jumpangern C; Israngkul Na Ayuthaya I
    Biomed Imaging Interv J; 2008 Jan; 4(1):e4. PubMed ID: 21614315
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Normalized sensitometric curves for the verification of hybrid IMRT treatment plans with multiple energies.
    Georg D; Kroupa B; Winkler P; Pötter R
    Med Phys; 2003 Jun; 30(6):1142-50. PubMed ID: 12852539
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetry of therapeutic photon beams using an extended dose range film.
    Esthappan J; Mutic S; Harms WB; Dempsey JF; Low DA
    Med Phys; 2002 Oct; 29(10):2438-45. PubMed ID: 12408321
    [TBL] [Abstract][Full Text] [Related]  

  • 8. EDR2 film dosimetry for IMRT verification using low-energy photon filters.
    Yeo IJ; Beiki-Ardakani A; Cho YB; Heydarian M; Zhang T; Islam M
    Med Phys; 2004 Jul; 31(7):1960-3. PubMed ID: 15305446
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry.
    Chetty IJ; Charland PM
    Phys Med Biol; 2002 Oct; 47(20):3629-41. PubMed ID: 12433124
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The response of Kodak EDR2 film in high-energy electron beams.
    Gerbi BJ; Dimitroyannis DA
    Med Phys; 2003 Oct; 30(10):2703-5. PubMed ID: 14596308
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Rapid radiographic film calibration for IMRT verification using automated MLC fields.
    Childress NL; Dong L; Rosen II
    Med Phys; 2002 Oct; 29(10):2384-90. PubMed ID: 12408313
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of film dosimetry techniques used for quality assurance of intensity modulated radiation therapy.
    Ju SG; Han Y; Kum O; Cheong KH; Shin EH; Shin JS; Kim JS; Ahn YC
    Med Phys; 2010 Jun; 37(6):2925-33. PubMed ID: 20632604
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of processing time delay on the dose response of Kodak EDR2 film.
    Childress NL; Rosen II
    Med Phys; 2004 Aug; 31(8):2284-8. PubMed ID: 15377095
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pencil beam approach for correcting the energy dependence artifact in film dosimetry for IMRT verification.
    Kirov AS; Caravelli G; Palm A; Chui C; LoSasso T
    Med Phys; 2006 Oct; 33(10):3690-9. PubMed ID: 17089835
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2O3:C) for film dosimetry in radiotherapy.
    Schembri V; Heijmen BJ
    Med Phys; 2007 Jun; 34(6):2113-8. PubMed ID: 17654914
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High sensitivity radiochromic film dose comparisons.
    Butson MJ; Yu PK; Cheung T; Metcalfe P
    Phys Med Biol; 2002 Nov; 47(22):N291-5. PubMed ID: 12476988
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of Kodak EDR2 and Gafchromic EBT film for intensity-modulated radiation therapy dose distribution verification.
    Sankar A; Ayyangar KM; Nehru RM; Kurup PG; Murali V; Enke CA; Velmurugan J
    Med Dosim; 2006; 31(4):273-82. PubMed ID: 17134667
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A method for improved verification of entire IMRT plans by film dosimetry.
    Jacob V; Kneschaurek P
    Strahlenther Onkol; 2009 Jan; 185(1):34-40. PubMed ID: 19224145
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of the epson expression 1680 flatbed and the vidar VXR-16 dosimetry PRO film scanners for use in IMRT dosimetry using gafchromic and radiographic film.
    Wilcox E; Daskalov G; Nedialkova L
    Med Phys; 2007 Jan; 34(1):41-8. PubMed ID: 17278488
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intensity modulated radiation therapy: film verification of planar dose maps.
    Tangboonduangjit P; Wu I; Butson M; Rosenfeld A; Metcalfe P
    Australas Phys Eng Sci Med; 2003 Dec; 26(4):194-9. PubMed ID: 14995065
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.