These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 12478870)

  • 1. Modified Ross procedure with stentless bioprosthesis and pericardial xenograft for the right ventricular outflow tract. Usefulness of autologous pericardial patch for hemostasis.
    Minami H; Wakita N; Mimura T; Inoue K; Sakata M; Okita Y
    Jpn J Thorac Cardiovasc Surg; 2002 Nov; 50(11):484-6. PubMed ID: 12478870
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An expanded polytetrafluoroethylene-autologous aortic hybrid valve for right ventricular outflow tract reconstruction in the Ross procedure.
    Miyazaki T; Yamagishi M; Shuntoh K; Yaku H
    Interact Cardiovasc Thorac Surg; 2007 Apr; 6(2):163-6. PubMed ID: 17669799
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Repair of a quadricuspid truncal valve by tricuspidization and reconstruction of right ventricular outflow tract with the excised truncal cusp.
    Wei LY; Chen YS; Chiu IS; Huang SC
    J Thorac Cardiovasc Surg; 2018 Mar; 155(3):1186-1189. PubMed ID: 29248281
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bicuspid aortic valve replacement with stentless autologous pericardial valve.
    Gupta A; Gharde P; Sampath Kumar A
    Asian Cardiovasc Thorac Ann; 2010 Oct; 18(5):481-2. PubMed ID: 20947605
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reconstruction of right ventricular outflow tract with stentless xenografts in Ross procedure.
    Tsukube T; Kawanishi Y; Murakami H; Hino Y; Matsukawa R; Ozaki N; Okada K; Matsuda H; Wakita N; Nishiwaki M; Okita Y
    Artif Organs; 2002 Dec; 26(12):1055-9. PubMed ID: 12460385
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Reconstruction of the normal right ventricle outflow tract in the Ross operation].
    Urrea Ramos MS; Herrera Alarcón V; Santibáñez Salgado JA; Celaya Lara S; Ono Okabe S; Molina Méndez J; Vargas Barrón J; Araya Gómez V; Romero Cárdenas A; Aranda Fraustro A
    Arch Inst Cardiol Mex; 1994; 64(2):175-82. PubMed ID: 8074588
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Right Ventricular Outflow Tract Replacement With Xenografts in Ross Patients Older Than 60 Years.
    Karaskov A; Bogachev-Prokophiev A; Sharifulin R; Zheleznev S; Demin I; Pivkin A; Zhuravleva I
    Ann Thorac Surg; 2016 Jun; 101(6):2252-9. PubMed ID: 27012586
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Autologous vs bovine pericardial valved patch for widening of the right ventricular outflow tract of tetralogy of Fallot].
    Haneda K; Shoji Y; Togo T; Ito Y; Sato N; Mohri H
    Rinsho Kyobu Geka; 1994 Apr; 14(2):129-32. PubMed ID: 9423084
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Truly stentless autologous pericardial aortic valve replacement: an alternative to standard aortic valve replacement.
    Chan KM; Rahman-Haley S; Mittal TK; Gavino JA; Dreyfus GD
    J Thorac Cardiovasc Surg; 2011 Jan; 141(1):276-83. PubMed ID: 20965520
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ventricular Septal Defect from Aortic Regurgitation Jet Lesion in Aortic Valve Infective Endocarditis.
    Darabant S; Oberton SB; Roldan LP; Roldan CA
    J Heart Valve Dis; 2016 Mar; 25(2):150-152. PubMed ID: 27989057
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Patching of the raw surface of the posterior right ventricular wall in Ross procedure to prevent bleeding and to confirm anastomosis of the conduit].
    Murakami J; Imoto Y; Shiokawa Y; Kanegae Y; Tokunaga S; Minami K; Kajihara N; Kado H
    Kyobu Geka; 2000 Nov; 53(12):1016-8. PubMed ID: 11079306
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison between homografts and Freestyle® bioprosthesis for right ventricular outflow tract replacement in Ross procedures.
    Miskovic A; Monsefi N; Doss M; Özaslan F; Karimian A; Moritz A
    Eur J Cardiothorac Surg; 2012 Dec; 42(6):927-33. PubMed ID: 22621871
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Effects of right ventricular outflow tract reconstruction with modified autologous pericardial monocuspid valve in patients with tetralogy of Fallot: a clinical research].
    Zhao WZ; Wen B; Shu LL
    Zhonghua Yi Xue Za Zhi; 2007 Oct; 87(40):2846-8. PubMed ID: 18167291
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Aortic valve replacement with biological substitutes in children.
    Talwar S; Malankar D; Garg S; Choudhary SK; Saxena A; Velayoudham D; Kumar AS
    Asian Cardiovasc Thorac Ann; 2012 Oct; 20(5):518-24. PubMed ID: 23087293
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A technique to prevent bleeding after Ross procedure.
    Kumar AS; Rao PN; Trehan H
    J Heart Valve Dis; 1995 Jul; 4(4):405-6. PubMed ID: 7582151
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Aortic valve replacement with freehand autologous pericardium.
    Duran CM; Gometza B; Kumar N; Gallo R; Martin-Duran R
    J Thorac Cardiovasc Surg; 1995 Aug; 110(2):511-6. PubMed ID: 7637369
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Alternative to pulmonary allograft for reconstruction of right ventricular outflow tract in small patients undergoing the Ross procedure.
    Oda T; Hoashi T; Kagisaki K; Shiraishi I; Yagihara T; Ichikawa H
    Eur J Cardiothorac Surg; 2012 Aug; 42(2):226-32; discussion 232. PubMed ID: 22402456
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stentless xenografts and homografts for right ventricular outflow tract reconstruction during the Ross operation.
    Schmid FX; Keyser A; Wiesenack C; Holmer S; Birnbaum DE
    Ann Thorac Surg; 2002 Sep; 74(3):684-8. PubMed ID: 12238824
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pericardial patch augmentation for repair of incompetent bicuspid aortic valves at midterm.
    Doss M; Sirat S; Risteski P; Martens S; Moritz A
    Eur J Cardiothorac Surg; 2008 May; 33(5):881-4. PubMed ID: 18343148
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Outcomes of a New-Generation Stentless Aortic Valve: A Single-Center Experience with 251 Consecutive Implants.
    Stefanelli G; Pirro F; Danniballe G; Olaru A; Meli M; Weltert L
    J Heart Valve Dis; 2017 Sep; 26(5):518-527. PubMed ID: 29762920
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.