294 related articles for article (PubMed ID: 12479623)
21. Superiority of transesophageal echocardiography in detecting aortic arch atheromatous disease: identification of patients at increased risk of stroke during cardiac surgery.
Marschall K; Kanchuger M; Kessler K; Grossi E; Yarmush L; Roggen S; Tissot M; Paglia S; Nacht A; Shrem S
J Cardiothorac Vasc Anesth; 1994 Feb; 8(1):5-13. PubMed ID: 8167285
[TBL] [Abstract][Full Text] [Related]
22. Protruding aortic atheromas predict stroke in elderly patients undergoing cardiopulmonary bypass: experience with intraoperative transesophageal echocardiography.
Katz ES; Tunick PA; Rusinek H; Ribakove G; Spencer FC; Kronzon I
J Am Coll Cardiol; 1992 Jul; 20(1):70-7. PubMed ID: 1607541
[TBL] [Abstract][Full Text] [Related]
23. Transesophageal echocardiographically detected atherosclerotic aortic debris in a patient with systemic embolism following coronary angiography.
Sato Y; Takei H; Katsumata N; Matsumoto N; Akiyama H; Narumiya T; Saito F; Kurumatani H; Sakamaki T; Kanmatsuse K
Heart Vessels; 1995; 10(3):167-9. PubMed ID: 7673089
[TBL] [Abstract][Full Text] [Related]
24. Propensity case-matched analysis of off-pump versus on-pump coronary artery bypass grafting in patients with atheromatous aorta.
Mishra M; Malhotra R; Karlekar A; Mishra Y; Trehan N
Ann Thorac Surg; 2006 Aug; 82(2):608-14. PubMed ID: 16863772
[TBL] [Abstract][Full Text] [Related]
25. Dual-helical CT for detecting aortic atheromas as a source of stroke: comparison with transesophageal echocardiography.
Tenenbaum A; Garniek A; Shemesh J; Fisman EZ; Stroh CI; Itzchak Y; Vered Z; Motro M
Radiology; 1998 Jul; 208(1):153-8. PubMed ID: 9646807
[TBL] [Abstract][Full Text] [Related]
26. Mild to moderate atheromatous disease of the thoracic aorta and new ischemic brain lesions after conventional coronary artery bypass graft surgery.
Djaiani G; Fedorko L; Borger M; Mikulis D; Carroll J; Cheng D; Karkouti K; Beattie S; Karski J
Stroke; 2004 Sep; 35(9):e356-8. PubMed ID: 15284448
[TBL] [Abstract][Full Text] [Related]
27. [Evaluation of thoracic aortic atherosclerosis by transesophageal ultrasonography: value and limits as predictive factor of coronary disease].
Ben Halima A; Kachboura S; Selmi K; Mokaddem A; Makni H; Bachraoui K; Fradi I; Boujnah MR
Tunis Med; 2002 Nov; 80(11):703-13. PubMed ID: 12664521
[TBL] [Abstract][Full Text] [Related]
28. Mobile atheroma of the aortic arch and the risk of carotid artery disease.
Arko FR; Fritcher S; Mettauer M; Patterson DE; Buckley CJ; Manning LG
Am J Surg; 1999 Sep; 178(3):206-8. PubMed ID: 10527440
[TBL] [Abstract][Full Text] [Related]
29. The Hostile Thoracic Aorta: Management Considerations for Severe Aortic Atheroma in a Challenging Case of Coronary Artery Bypass Grafting and Mitral Valve Replacement.
Fernando RJ; Johnson SD; Augoustides JG; Patel PA; Gutsche JT; Ha B; Feinman JW; Weiss SJ; Cheruku S; McCartney SL; Dave N; Fabbro M; Morris BN
J Cardiothorac Vasc Anesth; 2019 Jan; 33(1):223-231. PubMed ID: 29685800
[No Abstract] [Full Text] [Related]
30. Assessment of thoracic aortic atheroma by echocardiography: a new classification and estimation of risk of dislodging atheroma during three surgical techniques.
Royse C; Royse A; Blake D; Grigg L
Ann Thorac Cardiovasc Surg; 1998 Apr; 4(2):72-7. PubMed ID: 9577001
[TBL] [Abstract][Full Text] [Related]
31. Early detection of the tip position and complication of the intra-aortic balloon pump catheter by perioperative transesophageal echocardiography.
Shih CT; Yang MW; Lai ST; Lin CY
Zhonghua Yi Xue Za Zhi (Taipei); 1994 Mar; 53(3):131-4. PubMed ID: 8174006
[TBL] [Abstract][Full Text] [Related]
32. Acute thoracic aortic thrombosis after intra-aortic balloon pumping.
Aggeli C; Barberis VI; Vlachopoulos C; Tsiamis E; Stefanadis C
Eur J Echocardiogr; 2006 Mar; 7(2):175-6. PubMed ID: 15908281
[TBL] [Abstract][Full Text] [Related]
33. Proximal aortic atheroma. An independent risk factor for cerebral ischemia.
Jones EF; Kalman JM; Calafiore P; Tonkin AM; Donnan GA
Stroke; 1995 Feb; 26(2):218-24. PubMed ID: 7831691
[TBL] [Abstract][Full Text] [Related]
34. Forcing open doors using images: ruptured aortic arch atheroma visualized by TEE in a stroke patient.
Benyounes N; Welschbillig S; Gout O; Williams M; Chevalier G; Obadia M
Int J Stroke; 2014 Aug; 9(6):E29-30. PubMed ID: 25043522
[No Abstract] [Full Text] [Related]
35. Impact of aortic stiffness on ischemic stroke in elderly patients.
Sugioka K; Hozumi T; Sciacca RR; Miyake Y; Titova I; Gaspard G; Sacco RL; Homma S; Di Tullio MR
Stroke; 2002 Aug; 33(8):2077-81. PubMed ID: 12154266
[TBL] [Abstract][Full Text] [Related]
36. Use of intraaortic balloon counter pulsation in a patient with tortuous aorta.
Chakravarthy M; Jawali V
Ann Card Anaesth; 2008; 11(1):35-7. PubMed ID: 18182757
[TBL] [Abstract][Full Text] [Related]
37. Intraaortic atherosclerotic debris by transesophageal echocardiography.
Karalis DG; Chandrasekaran K
Am Heart J; 1992 Dec; 124(6):1664. PubMed ID: 1462944
[No Abstract] [Full Text] [Related]
38. Atherosclerosis of the thoracic aorta and aortic debris as a marker of poor prognosis: benefit of oral anticoagulants.
Ferrari E; Vidal R; Chevallier T; Baudouy M
J Am Coll Cardiol; 1999 Apr; 33(5):1317-22. PubMed ID: 10193733
[TBL] [Abstract][Full Text] [Related]
39. Disrupted mobile aortic plaques are a major risk factor for systemic embolism in the elderly.
Tenenbaum A; Fisman EZ; Schneiderman J; Stroh CI; Shemesh J; Schwammenthal E; Vered Z; Motro M
Cardiology; 1998 May; 89(4):246-51. PubMed ID: 9643270
[TBL] [Abstract][Full Text] [Related]
40. Observations of coronary flow augmentation and balloon function during intraaortic balloon counterpulsation using transesophageal echocardiography.
Katz ES; Tunick PA; Kronzon I
Am J Cardiol; 1992 Jun; 69(19):1635-9. PubMed ID: 1598882
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]