These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
321 related articles for article (PubMed ID: 12482620)
1. New IFCC reference procedures for the determination of catalytic activity concentrations of five enzymes in serum: preliminary upper reference limits obtained in hospitalized subjects. Schumann G; Klauke R Clin Chim Acta; 2003 Jan; 327(1-2):69-79. PubMed ID: 12482620 [TBL] [Abstract][Full Text] [Related]
2. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 7. Certification of four reference materials for the determination of enzymatic activity of gamma-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase accord. Siekmann L; Bonora R; Burtis CA; Ceriotti F; Clerc-Renaud P; Férard G; Ferrero CA; Forest JC; Franck PF; Gella FJ; Hoelzel W; Jørgensen PJ; Kanno T; Kessner A; Klauke R; Kristiansen N; Lessinger JM; Linsinger TP; Misaki H; Mueller MM; Panteghini M; Pauwels J; Schiele F; Schimmel HG; Vialle A; Weidemann G; Schumann G; Clin Chem Lab Med; 2002 Jul; 40(7):739-45. PubMed ID: 12241024 [TBL] [Abstract][Full Text] [Related]
3. Reference values for alanine aminotransferase, α-amylase, aspartate aminotransferase, γ-glutamyltransferase and lactate dehydrogenase measured according to the IFCC standardization during uncomplicated pregnancy. Cattozzo G; Calonaci A; Albeni C; Guerra E; Franzini M; Ghezzi F; Ceriotti F Clin Chem Lab Med; 2013 Oct; 51(10):e239-41. PubMed ID: 23770561 [No Abstract] [Full Text] [Related]
4. Metrological traceability of values for catalytic concentration of enzymes assigned to a calibration material. Canalias F; Camprubí S; Sánchez M; Gella FJ Clin Chem Lab Med; 2006; 44(3):333-9. PubMed ID: 16519608 [TBL] [Abstract][Full Text] [Related]
5. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. ; Schumann G; Aoki R; Ferrero CA; Ehlers G; Férard G; Gella FJ; Jørgensen PJ; Kanno T; Kessner A; Klauke R; Kytzia HJ; Lessinger JM; Miller WG; Nagel R; Pauwels J; Schimmel H; Siekmann L; Weidemann G; Yoshida K; Ceriotti F Clin Chem Lab Med; 2006; 44(9):1146-55. PubMed ID: 16958612 [TBL] [Abstract][Full Text] [Related]
6. Common reference intervals for aspartate aminotransferase (AST), alanine aminotransferase (ALT) and γ-glutamyl transferase (GGT) in serum: results from an IFCC multicenter study. Ceriotti F; Henny J; Queraltó J; Ziyu S; Özarda Y; Chen B; Boyd JC; Panteghini M; ; Clin Chem Lab Med; 2010 Nov; 48(11):1593-601. PubMed ID: 21034260 [TBL] [Abstract][Full Text] [Related]
7. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase. Schumann G; Bonora R; Ceriotti F; Férard G; Ferrero CA; Franck PF; Gella FJ; Hoelzel W; Jørgensen PJ; Kanno T; Kessner A; Klauke R; Kristiansen N; Lessinger JM; Linsinger TP; Misaki H; Panteghini M; Pauwels J; Schiele F; Schimmel HG; Weidemann G; Siekmann L; Clin Chem Lab Med; 2002 Jul; 40(7):718-24. PubMed ID: 12241021 [TBL] [Abstract][Full Text] [Related]
8. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 6. Reference procedure for the measurement of catalytic concentration of gamma-glutamyltransferase. Schumann G; Bonora R; Ceriotti F; Férard G; Ferrero CA; Franck PF; Gella FJ; Hoelzel W; Jørgensen PJ; Kanno T; Kessner A; Klauke R; Kristiansen N; Lessinger JM; Linsinger TP; Misaki H; Panteghini M; Pauwels J; Schiele F; Schimmel HG; Weidemann G; Siekmann L; Clin Chem Lab Med; 2002 Jul; 40(7):734-8. PubMed ID: 12241023 [TBL] [Abstract][Full Text] [Related]
9. Production and certification of secondary enzyme reference materials (ERMs). Part 1: Preparation of the sera and some of their properties. Koedam JC; Steentjes GM; Buitenhuis S; Schmidt E; Klauke R Clin Chem; 1986 Oct; 32(10):1901-5. PubMed ID: 3757208 [TBL] [Abstract][Full Text] [Related]
10. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase. Schumann G; Bonora R; Ceriotti F; Clerc-Renaud P; Ferrero CA; Férard G; Franck PF; Gella FJ; Hoelzel W; Jørgensen PJ; Kanno T; Kessner A; Klauke R; Kristiansen N; Lessinger JM; Linsinger TP; Misaki H; Panteghini M; Pauwels J; Schimmel HG; Vialle A; Weidemann G; Siekmann L Clin Chem Lab Med; 2002 Jun; 40(6):643-8. PubMed ID: 12211663 [TBL] [Abstract][Full Text] [Related]
11. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase. Schumann G; Bonora R; Ceriotti F; Férard G; Ferrero CA; Franck PF; Gella FJ; Hoelzel W; Jørgensen PJ; Kanno T; Kessner A; Klauke R; Kristiansen N; Lessinger JM; Linsinger TP; Misaki H; Panteghini M; Pauwels J; Schiele F; Schimmel HG; Weidemann G; Siekmann L; Clin Chem Lab Med; 2002 Jul; 40(7):725-33. PubMed ID: 12241022 [TBL] [Abstract][Full Text] [Related]
12. Recommendations for carrying out standard ECCLS procedures (1988) for the catalytic concentrations of creatine kinase, aspartate aminotransferase, alanine aminotransferase and gamma-glutamyltransferase at 37 degrees C. Standardization Committee of the German Society for Clinical Chemistry, Enzyme Working Group of the German Society for Clinical Chemistry. Klauke R; Schmidt E; Lorentz K Eur J Clin Chem Clin Biochem; 1993 Dec; 31(12):901-9. PubMed ID: 7907890 [No Abstract] [Full Text] [Related]
13. Reference values for six enzymes in plasma from newborns and women at delivery. Kristensen SR; Hørder M; Pedersen GT Scand J Clin Lab Invest; 1979 Dec; 39(8):777-84. PubMed ID: 43584 [TBL] [Abstract][Full Text] [Related]
14. Enzyme catalytic concentrations in human plasma after a marathon. Soeder G; Golf SW; Graef V; Temme H; Brüstle A; Róka L; Bertschat F; Ibe K Clin Biochem; 1989 Apr; 22(2):155-9. PubMed ID: 2470533 [TBL] [Abstract][Full Text] [Related]
15. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C. Part 9: reference procedure for the measurement of catalytic concentration of alkaline phosphatase International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Scientific Division, Committee on Reference Systems of Enzymes (C-RSE) (1)). Schumann G; Klauke R; Canalias F; Bossert-Reuther S; Franck PF; Gella FJ; Jørgensen PJ; Kang D; Lessinger JM; Panteghini M; Ceriotti F Clin Chem Lab Med; 2011 Sep; 49(9):1439-46. PubMed ID: 21702699 [TBL] [Abstract][Full Text] [Related]
16. EQA/PT scheme to improve the equivalence of enzymatic results between mutual recognition laboratories in Beijing. Tong Q; Zhang S; Zuo C J Clin Lab Anal; 2021 Jun; 35(6):e23814. PubMed ID: 33948986 [TBL] [Abstract][Full Text] [Related]
17. Determination of Six Sigma Metric in Control of Enzymes Determination in Human Serum. Đido V; Ćorić J; Mujić J; Panjeta M; Bodulović A; Marjanović M Clin Lab; 2019 Jul; 65(7):. PubMed ID: 31307179 [TBL] [Abstract][Full Text] [Related]
18. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase. Schumann G; Bonora R; Ceriotti F; Clerc-Renaud P; Ferrero CA; Férard G; Franck PF; Gella FJ; Hoelzel W; Jørgensen PJ; Kanno T; Kessne A; Klauker R; Kristiansen N; Lessinger JM; Linsinger TP; Misaki H; Panteghini M; Pauwels J; Schimmel HG; Vialle A; Weidemann G; Siekmann L Clin Chem Lab Med; 2002 Jun; 40(6):635-42. PubMed ID: 12211662 [TBL] [Abstract][Full Text] [Related]
19. A two-year longitudinal reference range study for selected serum enzymes in a population more than 60 years of age. Tietz NW; Wekstein DR; Shuey DF; Brauer GA J Am Geriatr Soc; 1984 Aug; 32(8):563-70. PubMed ID: 6146645 [TBL] [Abstract][Full Text] [Related]
20. Temperature-converting factors for enzymes: comparison of methods. Heerspink W; Hafkenscheid JC; Siepel H; van der Ven-Jongekrÿg J; Dijt CC Enzyme; 1980; 25(5):333-41. PubMed ID: 6108854 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]