BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 12484487)

  • 1. Non-connected versus interconnected macroporosity in poly(2-hydroxyethyl methacrylate) polymers. An X-ray microtomographic and histomorphometric study.
    Filmon R; Retailleau-Gaborit N; Grizon F; Galloyer M; Cincu C; Basle MF; Chappard D
    J Biomater Sci Polym Ed; 2002; 13(10):1105-17. PubMed ID: 12484487
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomaterial porosity determined by fractal dimensions, succolarity and lacunarity on microcomputed tomographic images.
    N'Diaye M; Degeratu C; Bouler JM; Chappard D
    Mater Sci Eng C Mater Biol Appl; 2013 May; 33(4):2025-30. PubMed ID: 23498228
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characterization of pore structure in biologically functional poly(2-hydroxyethyl methacrylate)-poly(ethylene glycol) diacrylate (PHEMA-PEGDA).
    Zellander A; Zhao C; Kotecha M; Gemeinhart R; Wardlow M; Abiade J; Cho M
    PLoS One; 2014; 9(5):e96709. PubMed ID: 24816589
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of negatively charged groups (carboxymethyl) on the calcification of poly(2-hydroxyethyl methacrylate).
    Filmon R; Grizon F; Baslé MF; Chappaard D
    Biomaterials; 2002 Jul; 23(14):3053-9. PubMed ID: 12069348
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biodegradation of poly(2-hydroxyethyl methacrylate) (PHEMA) and poly{(2-hydroxyethyl methacrylate)-co-[poly(ethylene glycol) methyl ether methacrylate]} hydrogels containing peptide-based cross-linking agents.
    Casadio YS; Brown DH; Chirila TV; Kraatz HB; Baker MV
    Biomacromolecules; 2010 Nov; 11(11):2949-59. PubMed ID: 20961104
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Involvement of fractal geometry on solute permeation through porous poly (2-hydroxyethyl methacrylate) membranes.
    Yanagawa F; Onuki Y; Morishita M; Takayama K
    J Control Release; 2006 Jan; 110(2):395-399. PubMed ID: 16332400
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Highly superporous cholesterol-modified poly(2-hydroxyethyl methacrylate) scaffolds for spinal cord injury repair.
    Kubinová S; Horák D; Hejčl A; Plichta Z; Kotek J; Syková E
    J Biomed Mater Res A; 2011 Dec; 99(4):618-29. PubMed ID: 21953978
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three-dimensional arrangement of β-tricalcium phosphate granules evaluated by microcomputed tomography and fractal analysis.
    Ndiaye M; Terranova L; Mallet R; Mabilleau G; Chappard D
    Acta Biomater; 2015 Jan; 11():404-11. PubMed ID: 25242650
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Preparation of macroporous poly(2-hydroxyethyl methacrylate) hydrogels by enhanced phase separation.
    Liu Q; Hedberg EL; Liu Z; Bahulekar R; Meszlenyi RK; Mikos AG
    Biomaterials; 2000 Nov; 21(21):2163-9. PubMed ID: 10985489
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of the length of crosslink chain on poly(2-hydroxyethyl methacrylate) (pHEMA) swelling and biomechanical properties.
    Mabilleau G; Stancu IC; Honoré T; Legeay G; Cincu C; Baslé MF; Chappard D
    J Biomed Mater Res A; 2006 Apr; 77(1):35-42. PubMed ID: 16345096
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The differential effects of poly(2-hydroxyethyl methacrylate) and poly(2-hydroxyethyl methacrylate)/poly(caprolactone) polymers on cell proliferation and collagen synthesis by human lung fibroblasts.
    Peluso G; Petillo O; Anderson JM; Ambrosio L; Nicolais L; Melone MA; Eschbach FO; Huang SJ
    J Biomed Mater Res; 1997 Mar; 34(3):327-36. PubMed ID: 9086402
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Morphological and topographic effects on calcification tendency of pHEMA hydrogels.
    Lou X; Vijayasekaran S; Sugiharti R; Robertson T
    Biomaterials; 2005 Oct; 26(29):5808-17. PubMed ID: 15949546
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Completely aqueous procedure for the growth of polymer brushes on polymeric substrates.
    Jain P; Dai J; Grajales S; Saha S; Baker GL; Bruening ML
    Langmuir; 2007 Nov; 23(23):11360-5. PubMed ID: 17918978
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Acrylic scaffolds with interconnected spherical pores and controlled hydrophilicity for tissue engineering.
    Diego RB; Olmedilla MP; Aroca AS; Ribelles JL; Pradas MM; Ferrer GG; Sánchez MS
    J Mater Sci Mater Med; 2005 Aug; 16(8):693-8. PubMed ID: 15965737
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Novel scaffolds based on poly(2-hydroxyethyl methacrylate) superporous hydrogels for bone tissue engineering.
    Çetin D; Kahraman AS; Gümüşderelioğlu M
    J Biomater Sci Polym Ed; 2011; 22(9):1157-78. PubMed ID: 20615330
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Macroporous microbeads containing apatite-modified mesoporous bioactive glass nanofibres for bone tissue engineering applications.
    Hsu FY; Hsu HW; Chang YH; Yu JL; Rau LR; Tsai SW
    Mater Sci Eng C Mater Biol Appl; 2018 Aug; 89():346-354. PubMed ID: 29752107
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomimetic macroporous hydrogels: protein ligand distribution and cell response to the ligand architecture in the scaffold.
    Savina IN; Dainiak M; Jungvid H; Mikhalovsky SV; Galaev IY
    J Biomater Sci Polym Ed; 2009; 20(12):1781-95. PubMed ID: 19723441
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Porosity imaged by a vector projection algorithm correlates with fractal dimension measured on 3D models obtained by microCT.
    Chappard D; Stancu IC
    J Microsc; 2015 Apr; 258(1):24-30. PubMed ID: 25556606
    [TBL] [Abstract][Full Text] [Related]  

  • 19. SIKVAV-modified highly superporous PHEMA scaffolds with oriented pores for spinal cord injury repair.
    Kubinová Š; Horák D; Hejčl A; Plichta Z; Kotek J; Proks V; Forostyak S; Syková E
    J Tissue Eng Regen Med; 2015 Nov; 9(11):1298-309. PubMed ID: 23401421
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reductively Degradable Poly(2-hydroxyethyl methacrylate) Hydrogels with Oriented Porosity for Tissue Engineering Applications.
    Macková H; Plichta Z; Hlídková H; Sedláček O; Konefal R; Sadakbayeva Z; Dušková-Smrčková M; Horák D; Kubinová Š
    ACS Appl Mater Interfaces; 2017 Mar; 9(12):10544-10553. PubMed ID: 28287694
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.