380 related articles for article (PubMed ID: 12488853)
21. In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design.
Kim SG; Park JU; Jeong JH; Bae C; Bae TS; Chee W
Int J Oral Maxillofac Implants; 2009; 24(6):1061-7. PubMed ID: 20162110
[TBL] [Abstract][Full Text] [Related]
22. Effect of engaging abutment position in implant-borne, screw-retained three-unit fixed cantilevered prostheses.
Dogus SM; Kurtz KS; Watanabe I; Griggs JA
J Prosthodont; 2011 Jul; 20(5):348-54. PubMed ID: 21585587
[TBL] [Abstract][Full Text] [Related]
23. The influence of veneering porcelain thickness of all-ceramic and metal ceramic crowns on failure resistance after cyclic loading.
Shirakura A; Lee H; Geminiani A; Ercoli C; Feng C
J Prosthet Dent; 2009 Feb; 101(2):119-27. PubMed ID: 19167536
[TBL] [Abstract][Full Text] [Related]
24. Fracture resistance of titanium and zirconia abutments: an in vitro study.
Foong JK; Judge RB; Palamara JE; Swain MV
J Prosthet Dent; 2013 May; 109(5):304-12. PubMed ID: 23684280
[TBL] [Abstract][Full Text] [Related]
25. Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crowns.
Freitas AC; Bonfante EA; Rocha EP; Silva NR; Marotta L; Coelho PG
Eur J Oral Sci; 2011 Aug; 119(4):323-30. PubMed ID: 21726295
[TBL] [Abstract][Full Text] [Related]
26. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.
Tan BF; Tan KB; Nicholls JI
Int J Oral Maxillofac Implants; 2004; 19(5):648-58. PubMed ID: 15508980
[TBL] [Abstract][Full Text] [Related]
27. In vitro assessment of three types of zirconia implant abutments under static load.
Kim JS; Raigrodski AJ; Flinn BD; Rubenstein JE; Chung KH; Mancl LA
J Prosthet Dent; 2013 Apr; 109(4):255-63. PubMed ID: 23566607
[TBL] [Abstract][Full Text] [Related]
28. Critical bending moment of four implant-abutment interface designs.
Lee FK; Tan KB; Nicholls JI
Int J Oral Maxillofac Implants; 2010; 25(4):744-51. PubMed ID: 20657869
[TBL] [Abstract][Full Text] [Related]
29. Load fatigue performance of conical implant-abutment connections.
Seetoh YL; Tan KB; Chua EK; Quek HC; Nicholls JI
Int J Oral Maxillofac Implants; 2011; 26(4):797-806. PubMed ID: 21841990
[TBL] [Abstract][Full Text] [Related]
30. Cement thickness at implant-supported single-tooth Lava assemblies: a scanning electron microscopic investigation.
Apicella D; Veltri M; Chieffi N; Balleri P; Ferrari M
Clin Oral Implants Res; 2010 Jul; 21(7):747-50. PubMed ID: 20636729
[TBL] [Abstract][Full Text] [Related]
31. Tensile bond strength of cast commercially pure titanium and cast gold-alloy posts and cores cemented with two luting agents.
Menani LR; Ribeiro RF; Antunes RP
J Prosthet Dent; 2008 Feb; 99(2):141-7. PubMed ID: 18262015
[TBL] [Abstract][Full Text] [Related]
32. The effect of engaging the screw access channel of an implant abutment with a cement-retained restoration.
Naik S; Tredwin CJ; Nesbit M; Setchell DJ; Moles DR
J Prosthodont; 2009 Apr; 18(3):245-8. PubMed ID: 19141047
[TBL] [Abstract][Full Text] [Related]
33. Probabilistic analysis of preload in the abutment screw of a dental implant complex.
Guda T; Ross TA; Lang LA; Millwater HR
J Prosthet Dent; 2008 Sep; 100(3):183-93. PubMed ID: 18762030
[TBL] [Abstract][Full Text] [Related]
34. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies.
Byrne D; Jacobs S; O'Connell B; Houston F; Claffey N
J Prosthodont; 2006; 15(3):164-71. PubMed ID: 16681498
[TBL] [Abstract][Full Text] [Related]
35. Evaluation of the ITI Morse taper implant/abutment design with an internal modification.
Ding TA; Woody RD; Higginbottom FL; Miller BH
Int J Oral Maxillofac Implants; 2003; 18(6):865-72. PubMed ID: 14696662
[TBL] [Abstract][Full Text] [Related]
36. Effect of axial wall modification on the retention of cement-retained, implant-supported crowns.
Tan KM; Masri R; Driscoll CF; Limkangwalmongkol P; Romberg E
J Prosthet Dent; 2012 Feb; 107(2):80-5. PubMed ID: 22304741
[TBL] [Abstract][Full Text] [Related]
37. A comparison of fabrication precision and mechanical reliability of 2 zirconia implant abutments.
Kerstein RB; Radke J
Int J Oral Maxillofac Implants; 2008; 23(6):1029-36. PubMed ID: 19216271
[TBL] [Abstract][Full Text] [Related]
38. Influence of the height of the external hexagon and surface treatment on fatigue life of commercially pure titanium dental implants.
Gil FJ; Aparicio C; Manero JM; Padros A
Int J Oral Maxillofac Implants; 2009; 24(4):583-90. PubMed ID: 19885397
[TBL] [Abstract][Full Text] [Related]
39. Wave analysis of implant screw loosening using an air cylindrical cyclic loading device.
Lee J; Kim YS; Kim CW; Han JS
J Prosthet Dent; 2002 Oct; 88(4):402-8. PubMed ID: 12447217
[TBL] [Abstract][Full Text] [Related]
40. Stability of implant-abutment interface with a hexagon-mediated butt joint: failure mode and bending resistance.
Khraisat A
Clin Implant Dent Relat Res; 2005; 7(4):221-8. PubMed ID: 16336913
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]