These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

89 related articles for article (PubMed ID: 1249026)

  • 1. Detection of volatile solvents in gastric contents by gas phase infrared spectrophotometry.
    Fastlich E
    J Assoc Off Anal Chem; 1976 Jan; 59(1):130-3. PubMed ID: 1249026
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [An infrared spectrophotometric method for determining acetone in the air of a work area in the presence of other solvents].
    Panev T
    Probl Khig; 1993; 18():132-9. PubMed ID: 7845963
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fourier transform infrared (FTIR) spectroscopy for monitoring airborne gases and vapors of industrial hygiene concern.
    Ying LS; Levine SP; Strang CR; Herget WF
    Am Ind Hyg Assoc J; 1989 Jul; 50(7):354-9. PubMed ID: 2756866
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intoxications mortelles de "sniffers" par des solvants volatils: identification par chromatographie en phase gazeuse couplée à la spectrométrie infra-rouge par transformée de Fourier [Fatal poisonings in sniffers of volatile solvents: identification by gas-phase chromatography coupled to infrared spectrometry with a Fourier transform].
    Deveaux M; Huvenne JP; Muller PH; Fleury G
    Acta Med Leg Soc (Liege); 1984; 34():161-8. PubMed ID: 6242905
    [No Abstract]   [Full Text] [Related]  

  • 5. Loop system for creating jet fuel vapor standards used in the calibration of infrared spectrophotometers and gas chromatographs.
    Reboulet J; Cunningham R; Gunasekar PG; Chapman GD; Stevens SC
    Toxicol Mech Methods; 2009 Feb; 19(2):123-8. PubMed ID: 19778256
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analysis of class 1 residual solvents in pharmaceuticals using headspace-programmed temperature vaporization-fast gas chromatography-mass spectrometry.
    Pérez Pavón JL; Del Nogal Sánchez M; Fernández Laespada MA; García Pinto C; Moreno Cordero B
    J Chromatogr A; 2007 Feb; 1141(1):123-30. PubMed ID: 17196213
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new method to obtain Fourier transform infrared spectra free from water vapor disturbance.
    Chen Y; Wang HS; Umemura J
    Appl Spectrosc; 2010 Oct; 64(10):1186-9. PubMed ID: 20925991
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of solvent vapors in breath and ambient air with a surface acoustic wave sensor array.
    Groves WA; Zellers ET
    Ann Occup Hyg; 2001 Nov; 45(8):609-23. PubMed ID: 11718657
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Systematic gas chromatographic studies of volatile organic substances of toxicologic significance].
    Bremer H; Tiess D
    Z Med Labortech; 1976; 17(3):107-10. PubMed ID: 983228
    [No Abstract]   [Full Text] [Related]  

  • 10. [The comparative characteristics of methods for determining technological liquids in clinical toxicology].
    Kliuev AE; Koldaev AA; Belova MV
    Sud Med Ekspert; 1998; 41(6):34-6. PubMed ID: 9989173
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Importance of gas-phase proton affinities in determining the electrospray ionization response for analytes and solvents.
    Amad MH; Cech NB; Jackson GS; Enke CG
    J Mass Spectrom; 2000 Jul; 35(7):784-9. PubMed ID: 10934432
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Comparison of standard methods for determination of pseudocumene in urine using gas chromatography with the headspace technique and a new method using a headspace automatic sampler].
    Kostrzewski P; Wiaderna-Brycht A; Czerski B
    Med Pr; 1996; 47(6):605-13. PubMed ID: 9091763
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Analysis of breath alcohol via infrared spectrophotometry: predicting false ethanol results by application of the base-line method to vapor phase infrared spectra.
    Labianca DA
    Eur J Clin Chem Clin Biochem; 1996 Jan; 34(1):59-61. PubMed ID: 8704037
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The full evaporation technique: a promising alternative for residual solvents analysis in solid samples.
    Brault A; Agasse V; Cardinael P; Combret JC
    J Sep Sci; 2005 Mar; 28(4):380-6. PubMed ID: 15792253
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Vapor-phase infrared laser spectroscopy: from gas sensing to forensic urinalysis.
    Bartlome R; Rey JM; Sigrist MW
    Anal Chem; 2008 Jul; 80(14):5334-41. PubMed ID: 18558771
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Establishment of a knowledge base for identification of residual solvents in pharmaceuticals.
    Liu Y; Hu CQ
    Anal Chim Acta; 2006 Aug; 575(2):246-54. PubMed ID: 17723598
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitative vapor-phase infrared spectrometry of ammonia.
    Shao L; Griffiths PR; Chu PM; Vetter TW
    Appl Spectrosc; 2006 Mar; 60(3):254-60. PubMed ID: 16608567
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Variable temperature infrared spectroscopy: a convenient tool for studying the thermodynamics of weak solid-gas interactions.
    Garrone E; Otero Areán C
    Chem Soc Rev; 2005 Oct; 34(10):846-57. PubMed ID: 16172674
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characterization of (E,E)-farnesol and its fatty acid esters from anal scent glands of nutria (Myocastor coypus) by gas chromatography-mass spectrometry and gas chromatography-infrared spectrometry.
    Lee H; Finckbeiner S; Yu JS; Wiemer DF; Eisner T; Attygalle AB
    J Chromatogr A; 2007 Sep; 1165(1-2):136-43. PubMed ID: 17709112
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of solvent type and content on monomer conversion of a model resin system as a thin film.
    Holmes RG; Rueggeberg FA; Callan RS; Caughman F; Chan DC; Pashley DH; Looney SW
    Dent Mater; 2007 Dec; 23(12):1506-12. PubMed ID: 17368744
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.