131 related articles for article (PubMed ID: 12493511)
1. Impact of high intensity transient signals on the choice of mechanical aortic valve substitutes.
Laas J; Kseibi S; Perthel M; Klingbeil A; El-Ayoubi L; Alken A
Eur J Cardiothorac Surg; 2003 Jan; 23(1):93-6. PubMed ID: 12493511
[TBL] [Abstract][Full Text] [Related]
2. Downstream turbulence and high intensity transient signals (HITS) following aortic valve replacement with Medtronic Hall or St. Jude Medical valve substitutes.
Kleine P; Perthel M; Hasenkam JM; Nygaard H; Hansen SB; Laas J
Eur J Cardiothorac Surg; 2000 Jan; 17(1):20-4. PubMed ID: 10735407
[TBL] [Abstract][Full Text] [Related]
3. Effect of mechanical aortic valve orientation on coronary artery flow: comparison of tilting disc versus bileaflet prostheses in pigs.
Kleine P; Scherer M; Abdel-Rahman U; Klesius AA; Ackermann H; Moritz A
J Thorac Cardiovasc Surg; 2002 Nov; 124(5):925-32. PubMed ID: 12407375
[TBL] [Abstract][Full Text] [Related]
4. Hemolysis, high-intensity transient signals (HITS) and hemodynamic results after aortic valve replacement with the Medtronic Hall Easy-Fit heart valve prosthesis.
Warnecke RH; Laas J; Hecker H; Perthel M; Alken A
J Heart Valve Dis; 2006 Mar; 15(2):174-9. PubMed ID: 16607897
[TBL] [Abstract][Full Text] [Related]
5. Prospective randomized comparison of CarboMedics and St. Jude Medical bileaflet mechanical heart valve prostheses: ten-year follow-up.
Bryan AJ; Rogers CA; Bayliss K; Wild J; Angelini GD
J Thorac Cardiovasc Surg; 2007 Mar; 133(3):614-22. PubMed ID: 17320553
[TBL] [Abstract][Full Text] [Related]
6. Transcranial high-intensity Doppler signals in patients with mechanical heart valve prostheses: their relationship with abnormal intracavitary echoes.
Deklunder G; Lecroart JL; Savoye C; Coquet B; Houdas Y
J Heart Valve Dis; 1996 Nov; 5(6):662-7. PubMed ID: 8953445
[TBL] [Abstract][Full Text] [Related]
7. High-intensity transient signals (HITS) as a parameter for optimum orientation of mechanical aortic valves.
Kleine P; Perthel M; Hasenkam JM; Nygaard H; Hansen SB; Laas J
Thorac Cardiovasc Surg; 2000 Dec; 48(6):360-3. PubMed ID: 11145405
[TBL] [Abstract][Full Text] [Related]
8. Tilting disc versus bileaflet aortic valve substitutes: intraoperative and postoperative hemodynamic performance in humans.
Kleine P; Hasenkam MJ; Nygaard H; Perthel M; Wesemeyer D; Laas J
J Heart Valve Dis; 2000 Mar; 9(2):308-11; discussion 311-2. PubMed ID: 10772054
[TBL] [Abstract][Full Text] [Related]
9. Clinical relevance of intracranial high intensity transient signals in patients following prosthetic aortic valve replacement.
Kofidis T; Fischer S; Leyh R; Mair H; Deckert M; Haberl R; Haverich A; Reichart B
Eur J Cardiothorac Surg; 2002 Jan; 21(1):22-6. PubMed ID: 11788250
[TBL] [Abstract][Full Text] [Related]
10. Intracranial high-intensity transient signals after homograft or mechanical aortic valve replacement.
Lievense AM; Bakker SL; Dippel DW; Taams MA; Koudstaal PJ; Bogers AJ
J Cardiovasc Surg (Torino); 1998 Oct; 39(5):613-7. PubMed ID: 9833721
[TBL] [Abstract][Full Text] [Related]
11. [High-intensity transcranial Doppler signals in patients wearing heart valve prostheses: a prospective study].
D'Alfonso A; Milano AD; Codecasa R; De Carlo M; Nardi C; Orlandi G; Paoli C; Murri L; Bortolotti U
G Ital Cardiol; 1999 Apr; 29(4):401-10. PubMed ID: 10327318
[TBL] [Abstract][Full Text] [Related]
12. [Turbulence and high intensity transient signals (HITS) as a parameter for optimum orientation of mechanical heart valves].
Perthel M; Hasenkam JM; Nygaard H; Kupper W; Laas J
Z Kardiol; 2001; 90 Suppl 6():100-4. PubMed ID: 11826811
[TBL] [Abstract][Full Text] [Related]
13. Prospective evaluation of frequency and nature of transcranial high-intensity Doppler signals in prosthetic valve recipients.
Milano A; D'Alfonso A; Codecasa R; De Carlo M; Nardi C; Orlandi G; Landucci L; Bortolotti U
J Heart Valve Dis; 1999 Sep; 8(5):488-94. PubMed ID: 10517388
[TBL] [Abstract][Full Text] [Related]
14. Orientation of tilting disc and bileaflet aortic valve substitutes for optimal hemodynamics.
Laas J; Kleine P; Hasenkam MJ; Nygaard H
Ann Thorac Surg; 1999 Sep; 68(3):1096-9. PubMed ID: 10510028
[TBL] [Abstract][Full Text] [Related]
15. Impact of mechanical and biological aortic valve replacement on coronary perfusion: a prospective, randomized study.
Bakhtiary F; Abolmaali N; Dzemali O; Wittlinger T; Doss M; Moritz A; Kleine P
J Heart Valve Dis; 2006 Jan; 15(1):5-11; discussion 11. PubMed ID: 16480006
[TBL] [Abstract][Full Text] [Related]
16. [Turbulence and high intensity transient signals (HITS) as a parameter for optimum orientation of mechanical heart valves].
Perthel M; Hasenkam JM; Nygaard H; Kupper W; Laas J
Z Kardiol; 2001 Dec; 90(Suppl 6):100-4. PubMed ID: 24445796
[TBL] [Abstract][Full Text] [Related]
17. Comparative clinical outcomes with St. Jude Medical, Medtronic Hall and CarboMedics mechanical heart valves.
Masters RG; Helou J; Pipe AL; Keon WJ
J Heart Valve Dis; 2001 May; 10(3):403-9. PubMed ID: 11380109
[TBL] [Abstract][Full Text] [Related]
18. Long-term outcome after biologic versus mechanical aortic valve replacement in 841 patients.
Peterseim DS; Cen YY; Cheruvu S; Landolfo K; Bashore TM; Lowe JE; Wolfe WG; Glower DD
J Thorac Cardiovasc Surg; 1999 May; 117(5):890-7. PubMed ID: 10220680
[TBL] [Abstract][Full Text] [Related]
19. Mechanical aortic valve prostheses in the small aortic root: Top Hat versus standard CarboMedics aortic valve.
Roedler S; Czerny M; Neuhauser J; Zimpfer D; Gottardi R; Dunkler D; Wolner E; Grimm M
Ann Thorac Surg; 2008 Jul; 86(1):64-70. PubMed ID: 18573400
[TBL] [Abstract][Full Text] [Related]
20. Valve replacement in the small aortic annulus: prospective randomized trial of St. Jude with Medtronic Hall.
Fiore AC; Swartz M; Grunkemeier G; Dressler F; Peigh PS; McBride LR; Kaiser GC; Labovitz AJ; Barner HB
Eur J Cardiothorac Surg; 1997 Mar; 11(3):485-91; discussion 491-2. PubMed ID: 9105813
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]