These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 12503476)

  • 1. [Manual compression versus mechanical compression device (FemoStop) after diagnostic coronary angiography with/without intervention].
    Stiebellehner L; Nikfardjan M; Diem K; Atteneder M; Stulnig T; Priglinger U; Gottsauner-Wolf M; Huber K
    Wien Klin Wochenschr; 2002 Oct; 114(19-20):847-52. PubMed ID: 12503476
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Patient tolerance and resource utilization associated with an arterial closure versus an external compression device after percutaneous coronary intervention.
    Juergens CP; Leung DY; Crozier JA; Wong AM; Robinson JT; Lo S; Kachwalla H; Hopkins AP
    Catheter Cardiovasc Interv; 2004 Oct; 63(2):166-70. PubMed ID: 15390237
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty.
    Sanborn TA; Gibbs HH; Brinker JA; Knopf WD; Kosinski EJ; Roubin GS
    J Am Coll Cardiol; 1993 Nov; 22(5):1273-9. PubMed ID: 8227779
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of vascular sealing devices (VasoSeal and Perclose) versus assisted manual compression (Femostop) in transcatheter coronary interventions requiring abciximab (ReoPro).
    Chamberlin JR; Lardi AB; McKeever LS; Wang MH; Ramadurai G; Grunenwald P; Towne WP; Grassman ED; Leya FS; Lewis BE; Stein LH
    Catheter Cardiovasc Interv; 1999 Jun; 47(2):143-7; discussion 148. PubMed ID: 10376492
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of vascular closure devices vs manual compression after femoral artery puncture: the ISAR-CLOSURE randomized clinical trial.
    Schulz-Schüpke S; Helde S; Gewalt S; Ibrahim T; Linhardt M; Haas K; Hoppe K; Böttiger C; Groha P; Bradaric C; Schmidt R; Bott-Flügel L; Ott I; Goedel J; Byrne RA; Schneider S; Burgdorf C; Morath T; Kufner S; Joner M; Cassese S; Hoppmann P; Hengstenberg C; Pache J; Fusaro M; Massberg S; Mehilli J; Schunkert H; Laugwitz KL; Kastrati A;
    JAMA; 2014 Nov; 312(19):1981-7. PubMed ID: 25399273
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Efficacy of hemostatic puncture closing device for hemostasis and early ambulation after coronary angiography and angioplasty: results of a multicenter trial].
    Magosaki N; Hosoda S; Kawagishi N; Yamaguchi T; Sakatani H; Haze K; Itagane H; Otsuka M; Nobuyoshi M; Yokoi H
    J Cardiol; 1999 Sep; 34(3):131-8. PubMed ID: 10500973
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rationale and design of a randomised clinical trial comparing vascular closure device and manual compression to achieve haemostasis after diagnostic coronary angiography: the Instrumental Sealing of ARterial puncture site - CLOSURE device versus manual compression (ISAR-CLOSURE) trial.
    Xhepa E; Byrne RA; Schulz S; Helde S; Gewalt S; Cassese S; Linhardt M; Ibrahim T; Mehilli J; Hoppe K; Grupp K; Kufner S; Böttiger C; Hoppmann P; Burgdorf C; Fusaro M; Ott I; Schneider S; Hengstenberg C; Schunkert H; Laugwitz KL; Kastrati A;
    EuroIntervention; 2014 Jun; 10(2):198-203. PubMed ID: 24952057
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Initial experience with a new femoral artery closure device following percutaneous coronary intervention with glycoprotein IIb/IIIa inhibition.
    Ruygrok PN; Ormiston JA; Stewart JT; Webster MW; El Jack S; Simpson-Plaumann S; Kay IP; Chou TM
    Catheter Cardiovasc Interv; 2005 Oct; 66(2):185-91. PubMed ID: 16152652
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Closure of a persistent femoral artery pseudoaneurysm complicating coronary angioplasty using the femostop compression device and direct ultrasound visualization.
    Sabri N; Eddy P; Traverso R; Khania S
    Int J Card Imaging; 1995 Dec; 11(4):273-5. PubMed ID: 8596066
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty.
    Sanborn TA; Gibbs HH; Brinker JA; Knopf WD; Kosinksi EJ; Roubin GS
    J Invasive Cardiol; 1999 Sep; 11 Suppl B():6B-13B. PubMed ID: 10745611
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Randomised comparison of manual compression and FemoSeal™ vascular closure device for closure after femoral artery access coronary angiography: the CLOSure dEvices Used in everyday Practice (CLOSE-UP) study.
    Holm NR; Sindberg B; Schou M; Maeng M; Kaltoft A; Bøttcher M; Krusell LR; Hjort J; Thuesen L; Terkelsen CJ; Christiansen EH; Bøtker HE; Kristensen SD; Lassen JF;
    EuroIntervention; 2014 Jun; 10(2):183-90. PubMed ID: 24603054
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determining best practice: comparison of three methods of femoral sheath removal after cardiac interventional procedures.
    Benson LM; Wunderly D; Perry B; Kabboord J; Wenk T; Birdsall B; Vanderbos L; Roach V; Goole R; Crippen C; Nyirenda T; Rumsey L; Manguba G
    Heart Lung; 2005; 34(2):115-21. PubMed ID: 15761456
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Safety and efficacy of a 6 French perclose arterial suturing device following percutaneous coronary interventions: a pilot evaluation.
    Kornowski R; Brandes S; Teplitsky I; Rechavia E; Shor N; Battler A; Assali A
    J Invasive Cardiol; 2002 Dec; 14(12):741-5. PubMed ID: 12454337
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanical compression versus haemostatic wound dressing after femoral artery sheath removal: a prospective, randomized study.
    Schwarz T; Rastan A; Pochert V; Sixt S; Schwarzwälder U; Bürgelin KH; Büttner HJ; Müller C; Neumann FJ; Zeller T
    Vasa; 2009 Feb; 38(1):53-9. PubMed ID: 19229804
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rapid arterial hemostasis and decreased access site complications after cardiac catheterization and angioplasty: results of a randomized trial of a novel hemostatic device.
    Kussmaul WG; Buchbinder M; Whitlow PL; Aker UT; Heuser RR; King SB; Kent KM; Leon MB; Kolansky DM; Sandza JG
    J Am Coll Cardiol; 1995 Jun; 25(7):1685-92. PubMed ID: 7759724
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Closure of the femoral artery after cardiac catheterization: a comparison of Angio-Seal, StarClose, and manual compression.
    Deuling JH; Vermeulen RP; Anthonio RA; van den Heuvel AF; Jaarsma T; Jessurun G; de Smet BJ; Tan ES; Zijlstra F
    Catheter Cardiovasc Interv; 2008 Mar; 71(4):518-23. PubMed ID: 18307223
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The inflammatory response to femoral arterial closure devices: a randomized comparison among FemoStop, AngioSeal, and Perclose.
    Jensen J; Saleh N; Jensen U; Svane B; Jönsson A; Tornvall P
    Cardiovasc Intervent Radiol; 2008; 31(4):751-5. PubMed ID: 18398639
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of the FemoStop device and manual pressure in reducing groin puncture site complications following coronary angioplasty and coronary stent placement.
    Walker SB; Cleary S; Higgins M
    Int J Nurs Pract; 2001 Dec; 7(6):366-75. PubMed ID: 11785439
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The safety and efficacy of the StarClose Vascular Closure System: the ultrasound substudy of the CLIP study.
    Jaff MR; Hadley G; Hermiller JB; Simonton C; Hinohara T; Cannon L; Reisman M; Braden G; Fletcher DR; Zapien M; Chou TM; DiDonato K
    Catheter Cardiovasc Interv; 2006 Nov; 68(5):684-9. PubMed ID: 17039509
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pseudoaneurysm of femoral artery after catheterisation: treatment by a mechanical compression device guided by colour Doppler ultrasound.
    Chatterjee T; Do DD; Mahler F; Meier B
    Heart; 1998 May; 79(5):502-4. PubMed ID: 9659200
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.