198 related articles for article (PubMed ID: 12505744)
1. Transthoracic impedance does not decrease with rapidly repeated countershocks in a swine cardiac arrest model.
Niemann JT; Garner D; Lewis RJ
Resuscitation; 2003 Jan; 56(1):91-5. PubMed ID: 12505744
[TBL] [Abstract][Full Text] [Related]
2. Quadriphasic waveforms are superior to triphasic waveforms for transthoracic defibrillation in a cardiac arrest swine model with high impedance.
Zhang Y; Rhee B; Davies LR; Zimmerman MB; Snyder D; Jones JL; Kerber RE
Resuscitation; 2006 Feb; 68(2):251-8. PubMed ID: 16325983
[TBL] [Abstract][Full Text] [Related]
3. The effects of biphasic and conventional monophasic defibrillation on postresuscitation myocardial function.
Tang W; Weil MH; Sun S; Yamaguchi H; Povoas HP; Pernat AM; Bisera J
J Am Coll Cardiol; 1999 Sep; 34(3):815-22. PubMed ID: 10483965
[TBL] [Abstract][Full Text] [Related]
4. Defibrillation probability and impedance change between shocks during resuscitation from out-of-hospital cardiac arrest.
Walker RG; Koster RW; Sun C; Moffat G; Barger J; Dodson PP; Chapman FW
Resuscitation; 2009 Jul; 80(7):773-7. PubMed ID: 19423211
[TBL] [Abstract][Full Text] [Related]
5. Interactions between CPR and defibrillation waveforms: effect on resumption of a perfusing rhythm after defibrillation.
Garcia LA; Allan JJ; Kerber RE
Resuscitation; 2000 Nov; 47(3):301-5. PubMed ID: 11114460
[TBL] [Abstract][Full Text] [Related]
6. Monophasic versus biphasic transthoracic countershock after prolonged ventricular fibrillation in a swine model.
Niemann JT; Burian D; Garner D; Lewis RJ
J Am Coll Cardiol; 2000 Sep; 36(3):932-8. PubMed ID: 10987622
[TBL] [Abstract][Full Text] [Related]
7. Transthoracic biphasic waveform defibrillation at very high and very low energies: a comparison with monophasic waveforms in an animal model of ventricular fibrillation.
Clark CB; Zhang Y; Davies LR; Karlsson G; Kerber RE
Resuscitation; 2002 Aug; 54(2):183-6. PubMed ID: 12161298
[TBL] [Abstract][Full Text] [Related]
8. Treatment of out-of-hospital cardiac arrest with a low-energy impedance-compensating biphasic waveform automatic external defibrillator. The LIFE Investigators.
Gliner BE; Jorgenson DB; Poole JE; White RD; Kanz KG; Lyster TD; Leyde KW; Powers DJ; Morgan CB; Kronmal RA; Bardy GH
Biomed Instrum Technol; 1998; 32(6):631-44. PubMed ID: 9883348
[TBL] [Abstract][Full Text] [Related]
9. A comparison of biphasic and monophasic waveform defibrillation after prolonged ventricular fibrillation.
Tang W; Weil MH; Sun S; Povoas HP; Klouche K; Kamohara T; Bisera J
Chest; 2001 Sep; 120(3):948-54. PubMed ID: 11555534
[TBL] [Abstract][Full Text] [Related]
10. Biphasic and monophasic transthoracic defibrillation in pigs with acute left ventricular dysfunction.
Zhang Y; Karlsson G; Davies LR; Coddington WJ; Kerber RE
Resuscitation; 2001 Jul; 50(1):95-101. PubMed ID: 11719135
[TBL] [Abstract][Full Text] [Related]
11. Effects of transthoracic impedance and peak current flow on defibrillation success in a prehospital setting.
Heavens JP; Cleland MJ; Maloney JP; Rowe BH
Ann Emerg Med; 1998 Aug; 32(2):191-9. PubMed ID: 9701302
[TBL] [Abstract][Full Text] [Related]
12. Electrocardiographic evaluation of defibrillation shocks delivered to out-of-hospital sudden cardiac arrest patients.
Gliner BE; White RD
Resuscitation; 1999 Jul; 41(2):133-44. PubMed ID: 10488935
[TBL] [Abstract][Full Text] [Related]
13. Immediate countershock versus cardiopulmonary resuscitation before countershock in a 5-minute swine model of ventricular fibrillation arrest.
Niemann JT; Cruz B; Garner D; Lewis RJ
Ann Emerg Med; 2000 Dec; 36(6):543-6. PubMed ID: 11097692
[TBL] [Abstract][Full Text] [Related]
14. Recurrent ventricular fibrillation during advanced life support care of patients with prehospital cardiac arrest.
Koster RW; Walker RG; Chapman FW
Resuscitation; 2008 Sep; 78(3):252-7. PubMed ID: 18556106
[TBL] [Abstract][Full Text] [Related]
15. Open-chest epicardial "surgical" defibrillation: biphasic versus monophasic waveform shocks.
Zhang Y; Davies LR; Coddington WJ; Zimmerman MB; Wuthrich S; Jones JL; Kerber RE
Pacing Clin Electrophysiol; 2003 Mar; 26(3):711-8. PubMed ID: 12698671
[TBL] [Abstract][Full Text] [Related]
16. Early out-of-hospital experience with an impedance-compensating low-energy biphasic waveform automatic external defibrillator.
White RD
J Interv Card Electrophysiol; 1997 Nov; 1(3):203-8; discussion 209-10. PubMed ID: 9869972
[TBL] [Abstract][Full Text] [Related]
17. Transthoracic monophasic and biphasic defibrillation in a swine model: a comparison of efficacy, ST segment changes, and postshock hemodynamics.
Niemann JT; Burian D; Garner D; Lewis RJ
Resuscitation; 2000 Sep; 47(1):51-8. PubMed ID: 11004381
[TBL] [Abstract][Full Text] [Related]
18. Is all ventricular fibrillation the same? A comparison of ischemically induced with electrically induced ventricular fibrillation in a porcine cardiac arrest and resuscitation model.
Niemann JT; Rosborough JP; Youngquist S; Thomas J; Lewis RJ
Crit Care Med; 2007 May; 35(5):1356-61. PubMed ID: 17414084
[TBL] [Abstract][Full Text] [Related]
19. Efficacy of lower-energy biphasic shocks for transthoracic defibrillation: a follow-up clinical study.
Higgins SL; O'Grady SG; Banville I; Chapman FW; Schmitt PW; Lank P; Walker RG; Ilina M
Prehosp Emerg Care; 2004; 8(3):262-7. PubMed ID: 15295725
[TBL] [Abstract][Full Text] [Related]
20. Determinants of successful transthoracic defibrillation and outcome in ventricular fibrillation.
Dalzell GW; Adgey AA
Br Heart J; 1991 Jun; 65(6):311-6. PubMed ID: 2054239
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]