These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 125256)

  • 21. Thermal quantification of region myocardial perfusion and heat generation.
    Hernandez EJ; Hoffman JK; Fabian M; Siegel JH; Eberhart RC
    Am J Physiol; 1979 Feb; 236(2):H345-55. PubMed ID: 420318
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Steady-state analysis of self-heated thermistors using finite elements.
    Hayes LJ; Valvano JW
    J Biomech Eng; 1985 Feb; 107(1):77-80. PubMed ID: 3981990
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Evaluation of the heated cross-thermocouples technique for measurement of myocardial tissue blood flow (author's transl)].
    Fujii Y; Oda T; Murata T; Furukawa S; Tomosawa N; Yamaki R
    Nihon Kyobu Geka Gakkai Zasshi; 1979 Nov; 27(11):1498-506. PubMed ID: 536629
    [No Abstract]   [Full Text] [Related]  

  • 24. Analysis of the Weinbaum-Jiji model of blood flow in the canine kidney cortex for self-heated thermistors.
    Valvano JW; Nho S; Anderson GT
    J Biomech Eng; 1994 May; 116(2):201-7. PubMed ID: 8078327
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A transcutaneous PO2 electrode incorporating a thermal clearance local blood flow sensor.
    Parker D; Delpy D; Reynolds EO; Andrew DS
    Acta Anaesthesiol Scand Suppl; 1978; 68():33-9. PubMed ID: 279198
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Experimental basis of a new method of determination of coronary blood flow with the aid of electromagnetic flowmeter].
    Portnoĭ VF; Dvortsin GF
    Kardiologiia; 1976 May; 16(5):118-23. PubMed ID: 133265
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Thermal anemometric assessment of coronary flow reserve with a pressure-sensing guide wire: an in vitro evaluation.
    van der Horst A; Geven MC; Rutten MC; Pijls NH; van de Vosse FN
    Med Eng Phys; 2011 Jul; 33(6):684-91. PubMed ID: 21288757
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A sensitivity analysis of the step-temperature technique for measurement of local tissue blood perfusion.
    Yang K; Liu W
    J Med Eng Technol; 2008; 32(1):73-82. PubMed ID: 18183522
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Measurement of thermal properties of living tissue in vivo].
    Che C; He J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 1997 Jun; 14(2):188-92. PubMed ID: 9817652
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Blood flow and heat transfer in Walker 256 mammary carcinoma.
    Jain RK; Grantham FH; Gullino PM
    J Natl Cancer Inst; 1979 Apr; 62(4):927-33. PubMed ID: 285296
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Measurement of venous blood flow and pressure using thermoelectric and pressure transducers.
    Soma T; Watanabe R; Bito K; Fujiwara H; Sato M
    Biomed Eng; 1975 Apr; 10(4):136-40. PubMed ID: 123791
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of the use of heated cross-thermo-couples for assessments of regional myocardial blood flow.
    Uchida Y; Ueda H
    Jpn Heart J; 1971 Nov; 12(6):562-74. PubMed ID: 5316570
    [No Abstract]   [Full Text] [Related]  

  • 33. Kidney temperature measurement. Thermistors for temperature measurement.
    Zát'ura F; Ramert B; Scheinar J; Reif R; Výborný K
    Acta Univ Palacki Olomuc Fac Med; 1994; 138():45-8. PubMed ID: 8714093
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Methods of thermal blood flow measurement.
    Priebe L
    Bibl Radiol; 1975; (6):33-44. PubMed ID: 1180860
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Determination of cerebral blood flow using a thermistor flow metry].
    Hisada S; Yamamoto H
    Igaku To Seibutsugaku; 1969 Jan; 78(1):11-3. PubMed ID: 5813559
    [No Abstract]   [Full Text] [Related]  

  • 36. Finite element analysis and experimental verification of multilayered tissue characterization using the thermal technique.
    Kharalkar NM; Valvano JW
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():3182-5. PubMed ID: 17946163
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A novel model of the pulse decay method for measurement of local tissue blood perfusion.
    Yang K; Liu W
    Med Eng Phys; 2004 Apr; 26(3):215-23. PubMed ID: 14984843
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Thermal pulse decay method for simultaneous measurement of local thermal conductivity and blood perfusion: a theoretical analysis.
    Arkin H; Holmes KR; Chen MM; Bottje WG
    J Biomech Eng; 1986 Aug; 108(3):208-14. PubMed ID: 3747464
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Direct calibration of a totally implantable pulsed Doppler ultrasonic blood flowmeter.
    Allen HV; Anderson MF; Meindl JD
    Am J Physiol; 1977 May; 232(5):H537-44. PubMed ID: 140611
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A sensitivity analysis of the Thermal Pulse Decay method for measurement of local tissue conductivity and blood perfusion.
    Arkin H; Holmes KR; Chen MM
    J Biomech Eng; 1986 Feb; 108(1):54-8. PubMed ID: 3959553
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.