These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

235 related articles for article (PubMed ID: 12525941)

  • 1. Posterior-anterior weight-bearing radiograph in 15 degree knee flexion in medial osteoarthritis.
    Yamanaka N; Takahashi T; Ichikawa N; Yamamoto H
    Skeletal Radiol; 2003 Jan; 32(1):28-34. PubMed ID: 12525941
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of radiographic joint space width in the tibiofemoral compartment of the osteoarthritic knee: comparison of standing anteroposterior and Lyon schuss views.
    Vignon E; Piperno M; Le Graverand MP; Mazzuca SA; Brandt KD; Mathieu P; Favret H; Vignon M; Merle-Vincent F; Conrozier T
    Arthritis Rheum; 2003 Feb; 48(2):378-84. PubMed ID: 12571846
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Radiographic methods in knee osteoarthritis: a further comparison of semiflexed (MTP), schuss-tunnel, and weight-bearing anteroposterior views for joint space narrowing and osteophytes.
    Wolfe F; Lane NE; Buckland-Wright C
    J Rheumatol; 2002 Dec; 29(12):2597-601. PubMed ID: 12465159
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of medial tibial plateau alignment on serial radiographs on the capacity to predict progression of knee osteoarthritis.
    Botha-Scheepers S; Dougados M; Ravaud P; Hellio Le Graverand MP; Watt I; Breedveld FC; Kloppenburg M
    Osteoarthritis Cartilage; 2008 Feb; 16(2):272-6. PubMed ID: 18262805
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fixed-flexion knee radiography: the sensitivity to detect knee joint space narrowing in osteoarthritis.
    Botha-Scheepers S; Kloppenburg M; Kroon HM; Hellio Le Graverand MP; Breedveld FC; Ravaud P; Dougados M
    Osteoarthritis Cartilage; 2007 Mar; 15(3):350-3. PubMed ID: 17074511
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of the radioanatomic positioning of the osteoarthritic knee in serial radiographs: comparison of three acquisition techniques.
    ; Le Graverand MP; Mazzuca S; Lassere M; Guermazi A; Pickering E; Brandt K; Peterfy C; Cline G; Nevitt M; Woodworth T; Conaghan P; Vignon E
    Osteoarthritis Cartilage; 2006; 14 Suppl A():A37-43. PubMed ID: 16785057
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Lyon Schuss radiographic view of the knee. Utility of fluoroscopy for the quality of tibial plateau alignment.
    Conrozier T; Mathieu P; Piperno M; Provvedini D; Taccoen A; Colson F; Duivon JP; Dusan R; Favret H; Vignon E
    J Rheumatol; 2004 Mar; 31(3):584-90. PubMed ID: 14994408
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Relationship between knee alignment and radiographic markers of osteoarthritis: a cross-sectional study from a Korean population.
    Im GI; Kim MK; Lee SH
    Int J Rheum Dis; 2016 Feb; 19(2):178-83. PubMed ID: 24251667
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance of a non-fluoroscopically assisted substitute for the Lyon schuss knee radiograph: quality and reproducibility of positioning and sensitivity to joint space narrowing in osteoarthritic knees.
    Mazzuca SA; Hellio Le Graverand MP; Vignon E; Hunter DJ; Jackson CG; Kraus VB; Link TM; Schnitzer TJ; Vaz A; Charles HC
    Osteoarthritis Cartilage; 2008 Dec; 16(12):1555-9. PubMed ID: 18515156
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detection of radiographic joint space narrowing in subjects with knee osteoarthritis: longitudinal comparison of the metatarsophalangeal and semiflexed anteroposterior views.
    Mazzuca SA; Brandt KD; Buckwalter KA
    Arthritis Rheum; 2003 Feb; 48(2):385-90. PubMed ID: 12571847
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The posteroanterior 45 degrees flexion weight-bearing radiograph of the knee.
    Mason RB; Horne JG
    J Arthroplasty; 1995 Dec; 10(6):790-2. PubMed ID: 8749762
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reproducibility of joint space width and the intermargin distance measurements in patients with medial osteoarthritis of the knee in various degrees of flexion.
    Takahashi T; Yamanaka N; Ikeuchi M; Yamamoto H
    Skeletal Radiol; 2009 Jan; 38(1):37-42. PubMed ID: 18773204
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Substantial superiority of semiflexed (MTP) views in knee osteoarthritis: a comparative radiographic study, without fluoroscopy, of standing extended, semiflexed (MTP), and schuss views.
    Buckland-Wright JC; Wolfe F; Ward RJ; Flowers N; Hayne C
    J Rheumatol; 1999 Dec; 26(12):2664-74. PubMed ID: 10606380
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Superiority of the Lyon schuss view over the standing anteroposterior view for detecting joint space narrowing, especially in the lateral tibiofemoral compartment, in early knee osteoarthritis.
    Merle-Vincent F; Vignon E; Brandt K; Piperno M; Coury-Lucas F; Conrozier T; Mathieu P; Hellio Le Graverand MP
    Ann Rheum Dis; 2007 Jun; 66(6):747-53. PubMed ID: 17227814
    [TBL] [Abstract][Full Text] [Related]  

  • 15. How do marginal osteophytes, joint space narrowing and range of motion affect each other in patients with knee osteoarthritis.
    Ozdemir F; Tukenmez O; Kokino S; Turan FN
    Rheumatol Int; 2006 Apr; 26(6):516-22. PubMed ID: 16025334
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The lateral view radiograph for assessment of the tibiofemoral joint space in knee osteoarthritis: its reliability, sensitivity to change, and longitudinal validity.
    LaValley MP; McLaughlin S; Goggins J; Gale D; Nevitt MC; Felson DT
    Arthritis Rheum; 2005 Nov; 52(11):3542-7. PubMed ID: 16255043
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Three-dimensional tibiofemoral articular contact kinematics of a cruciate-retaining total knee arthroplasty.
    Li G; Suggs J; Hanson G; Durbhakula S; Johnson T; Freiberg A
    J Bone Joint Surg Am; 2006 Feb; 88(2):395-402. PubMed ID: 16452753
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Selection of knee radiographs for trials of structure-modifying drugs in patients with knee osteoarthritis: a prospective, longitudinal study of Lyon Schuss knee radiographs with the definition of adequate alignment of the medial tibial plateau.
    Conrozier T; Mathieu P; Piperno M; Favret H; Colson F; Vignon M; Conrozier S; Vignon E
    Arthritis Rheum; 2005 May; 52(5):1411-7. PubMed ID: 15880526
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of alignment of the medial tibial plateau and x-ray beam on apparent progression of osteoarthritis in the standing anteroposterior knee radiograph.
    Mazzuca SA; Brandt KD; Dieppe PA; Doherty M; Katz BP; Lane KA
    Arthritis Rheum; 2001 Aug; 44(8):1786-94. PubMed ID: 11508430
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Head-to-head comparison of the Lyon Schuss and fixed flexion radiographic techniques. Long-term reproducibility in normal knees and sensitivity to change in osteoarthritic knees.
    Le Graverand MP; Vignon EP; Brandt KD; Mazzuca SA; Piperno M; Buck R; Charles HC; Hunter DJ; Jackson CG; Kraus VB; Link TM; Schnitzer TJ; Vaz A; Wyman B
    Ann Rheum Dis; 2008 Nov; 67(11):1562-6. PubMed ID: 18258709
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.