These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 12527246)

  • 21. New suture method for radial tears of the meniscus: biomechanical analysis of cross-suture and double horizontal suture techniques using cyclic load testing.
    Matsubara H; Okazaki K; Izawa T; Tashiro Y; Matsuda S; Nishimura T; Nakanishi Y; Kawamura H; Iwamoto Y
    Am J Sports Med; 2012 Feb; 40(2):414-8. PubMed ID: 22016457
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Strategies for repair of radial tears close to the meniscal rim--biomechanical analysis with a cyclic loading protocol.
    Herbort M; Siam S; Lenschow S; Petersen W; Zantop T
    Am J Sports Med; 2010 Nov; 38(11):2281-7. PubMed ID: 20889985
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Biomechanical Comparison of 3 Novel Repair Techniques for Radial Tears of the Medial Meniscus: The 2-Tunnel Transtibial Technique, a "Hybrid" Horizontal and Vertical Mattress Suture Configuration, and a Combined "Hybrid Tunnel" Technique.
    Buckley PS; Kemler BR; Robbins CM; Aman ZS; Storaci HW; Dornan GJ; LaPrade RF
    Am J Sports Med; 2019 Mar; 47(3):651-658. PubMed ID: 30624953
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Meniscal repair devices.
    Barber FA; Herbert MA
    Arthroscopy; 2000 Sep; 16(6):613-8. PubMed ID: 10976122
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Three single loops enhance the biomechanical behavior of the transtibial pull-out technique for posterior meniscal root repair.
    Camarda L; Pitarresi G; Lauria M; Fazzari F; D'Arienzo M
    Arch Orthop Trauma Surg; 2017 Sep; 137(9):1301-1306. PubMed ID: 28674738
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Refixation of the meniscus with the SD meniscal staple: a comparative biomechanical study on cadaver knees].
    Schoettle PB; Fredrich H; Steinhauser E; Imhoff AB
    Unfallchirurg; 2003 Feb; 106(2):114-20. PubMed ID: 12624685
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation.
    Zantop T; Eggers AK; Musahl V; Weimann A; Hassenpflug J; Petersen W
    Knee Surg Sports Traumatol Arthrosc; 2004 Jul; 12(4):317-24. PubMed ID: 14689168
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A biomechanical comparison of the FasT-Fix meniscal repair suture system and the RapidLoc device in cadaver meniscus.
    Kocabey Y; Chang HC; Brand JC; Nawab A; Nyland J; Caborn DN
    Arthroscopy; 2006 Apr; 22(4):406-13. PubMed ID: 16581453
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Elongation and structural properties of meniscal repair using suture techniques in distraction and shear force scenarios: biomechanical evaluation using a cyclic loading protocol.
    Zantop T; Temmig K; Weimann A; Eggers AK; Raschke MJ; Petersen W
    Am J Sports Med; 2006 May; 34(5):799-805. PubMed ID: 16567460
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Primary Fixation and Cyclic Performance of Single-Stitch All-Inside and Inside-Out Meniscal Devices for Repairing Vertical Longitudinal Meniscal Tears.
    Bachmaier S; Krych AJ; Smith PA; Herbort M; Ritter D; LaPrade RF; Wijdicks CA
    Am J Sports Med; 2022 Aug; 50(10):2705-2713. PubMed ID: 35787211
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Horizontal suture placement influences meniscal repair fixation strength.
    Kocabey Y; Taser O; Nyland J; Ince H; Sahin F; Sunbuloglu E; Baysal G
    Knee Surg Sports Traumatol Arthrosc; 2013 Mar; 21(3):615-9. PubMed ID: 22484371
    [TBL] [Abstract][Full Text] [Related]  

  • 32. All-inside meniscal repair devices compared with their matched inside-out vertical mattress suture repair: introducing 10,000 and 100,000 loading cycles.
    Rosso C; Müller S; Buckland DM; Schwenk T; Zimmermann S; de Wild M; Valderrabano V
    Am J Sports Med; 2014 Sep; 42(9):2226-33. PubMed ID: 24966304
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Cyclic test comparison of all-inside device and inside-out sutures for radial meniscus lesion repair: an in vitro porcine model study.
    Lee YH; Nyland J; Burden R; Caborn DN
    Arthroscopy; 2012 Dec; 28(12):1873-81. PubMed ID: 23085200
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Biomechanical testing of new meniscal repair techniques containing ultra high-molecular weight polyethylene suture.
    Barber FA; Herbert MA; Schroeder FA; Aziz-Jacobo J; Sutker MJ
    Arthroscopy; 2009 Sep; 25(9):959-67. PubMed ID: 19732633
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Arthroscopic meniscal repair with bioresorbable implants.
    Bohnsack M; Rühmann O
    Oper Orthop Traumatol; 2006 Dec; 18(5-6):425-52. PubMed ID: 17171329
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of all-inside meniscal repair devices with matched inside-out suture repair.
    Rosso C; Kovtun K; Dow W; McKenzie B; Nazarian A; DeAngelis JP; Ramappa AJ
    Am J Sports Med; 2011 Dec; 39(12):2634-9. PubMed ID: 21997730
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Medial Meniscal Root Avulsion: A Biomechanical Comparison of 4 Different Repair Constructs.
    Mitchell R; Pitts R; Kim YM; Matava MJ
    Arthroscopy; 2016 Jan; 32(1):111-9. PubMed ID: 26422709
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Meniscal repair using large diameter horizontal sutures increases fixation strength: an in vitro study.
    Kocabey Y; Taşer O; Hapa O; Güçlü A; Bozdag E; Sünbüloglu E; Doral M
    Knee Surg Sports Traumatol Arthrosc; 2011 Feb; 19(2):202-6. PubMed ID: 20602087
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Biomechanical study on different high-strength sutures and suture site for repairing posterior root tear of the medial meniscus].
    Wang JT; Bu JL; Shen XZ; Chang H; Teng LJ; Zhu JL; Liu Y; Liu Y
    Zhongguo Gu Shang; 2021 May; 34(5):442-7. PubMed ID: 34032046
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The Strength of Transosseous Medial Meniscal Root Repair Using a Simple Suture Technique Is Dependent on Suture Material and Position.
    Robinson JR; Frank EG; Hunter AJ; Jermin PJ; Gill HS
    Am J Sports Med; 2018 Mar; 46(4):924-932. PubMed ID: 29364699
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.