These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 12529923)

  • 1. Determination of carbon disulfide at the workplace by sampling on charcoal tubes--problems and solutions.
    Göen T; Müller J; Angerer J; Drexler H
    AIHA J (Fairfax, Va); 2002; 63(5):659-63. PubMed ID: 12529923
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A simple method for carbon disulfide monitoring using a diffusive sampler, thermal desorption and a stain tube.
    Tanaka S; Yamauchi T; Takebayashi T; Omae K; Seki Y
    Ind Health; 1997 Oct; 35(4):474-9. PubMed ID: 9348719
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A charcoal sampling method and a gas chromatographic analytical procedure for carbon disulfide.
    McCammon CS; Quinn PM; Kupel RE
    Am Ind Hyg Assoc J; 1975 Aug; 36(8):618-25. PubMed ID: 1227288
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [The improvement of determination method of carbon disulfide in workplace air with gas chromatography].
    Xiao QF; Qin WH; Lu YY; Yu SF
    Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2012 Jun; 30(6):471-2. PubMed ID: 22931783
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A charcoal sampling method and a colorimetric analytical procedure for carbon disulfide. Measurement data from a viscose rayon manufacturing plant.
    Westberg H; Jansson L; Andersson K
    G Ital Med Lav; 1984; 6(3-4):123-5. PubMed ID: 6534775
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and evaluation of a calibration gas generator for the analysis of volatile organic compounds in air based on the injection method.
    Rosenberg E; Hallama RA; Grasserbauer M
    Fresenius J Anal Chem; 2001 Nov; 371(6):798-805. PubMed ID: 11768469
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [The rervising of biological exposure index for carbon disulfide exposuring].
    Jiang KY; Wu H; Qin WH; Xiao QF; Lu YY; Cui SM; Yu SF
    Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2012 Jun; 30(6):479-81. PubMed ID: 22931787
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of a sampling and analytical method for 2,2-dichloro-1,1,1-trifluoroethane in workplace air.
    Shin YC; Yi GY; Kim Y; Paik NW
    AIHA J (Fairfax, Va); 2002; 63(6):715-20. PubMed ID: 12570079
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analysis of charcoal tube samples for carbon disulfide using a photoionization detector.
    Smith DB; Krause LA
    Am Ind Hyg Assoc J; 1978 Dec; 39(12):939-44. PubMed ID: 742595
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of benzene, toluene, ethylbenzene and xylenes in indoor air at environmental levels using diffusive samplers in combination with headspace solid-phase microextraction and high-resolution gas chromatography-flame ionization detection.
    Elke K; Jermann E; Begerow J; Dunemann L
    J Chromatogr A; 1998 Nov; 826(2):191-200. PubMed ID: 9871339
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Method for determining 1,2:3,4-Diepoxybutane in workplace air].
    Kowalska J; Jeżewska A
    Med Pr; 2016; 67(5):645-652. PubMed ID: 27819703
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development of a sampling and analysis method for 4-vinyl-1-cyclohexene in air.
    Kongtip P; Tangprakorn B; Yoosook W; Chantanakul S
    J Occup Health; 2008; 50(2):122-9. PubMed ID: 18403862
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Determination of time-weighted average concentration for vinyl chloride in the air of workplace].
    Liu J; Zheng LX; Chai SJ; Li J
    Wei Sheng Yan Jiu; 2006 May; 35(3):342-4. PubMed ID: 16921764
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Laboratory and field validation of a JXC charcoal sampling and analytical method for monitoring short-term exposures to ethylene oxide.
    Puskar MA; Nowak JL; Hecker LH
    Am Ind Hyg Assoc J; 1988 May; 49(5):237-43. PubMed ID: 3400587
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Determination of bromoform in the air of workplace by solvent desorption gas chromatography].
    Li XJ; Zhu BL; Wu J; Zhou CM; Gong W
    Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2016 Apr; 34(4):299-301. PubMed ID: 27514270
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prototype sampling system for measuring workplace protection factors for gases and vapors.
    Groves WA; Reynolds SJ
    Appl Occup Environ Hyg; 2003 May; 18(5):394-402. PubMed ID: 12746083
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Determination of isobutyl methacrylate in workplace air by gas chromatography].
    Zhang SH; Tan QT; Wang X
    Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2020 Aug; 38(8):628-630. PubMed ID: 32892597
    [No Abstract]   [Full Text] [Related]  

  • 18. The application of diffusive sampling combined with thermal desorption in occupational exposure monitoring--field evaluation.
    Chien YC; Wu LJ; Lwo JH
    Appl Occup Environ Hyg; 2003 May; 18(5):368-73. PubMed ID: 12746080
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of concurrent personal measurements of acrylonitrile using different sampling techniques.
    Zey JN; Stewart PA; Hornung R; Herrick R; McCammon C; Zaebst D; Pottern LM; Dosemeci M; Bloom TF
    Appl Occup Environ Hyg; 2002 Feb; 17(2):88-95. PubMed ID: 11843203
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Field evaluation of a passive sampler for assessing 2-ethoxyethyl acetate exposures.
    Shih TS; Chang HY; Liu HH; Hung YS; Liou SH
    J Occup Health; 2004 Nov; 46(6):479-85. PubMed ID: 15613771
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.