These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

65 related articles for article (PubMed ID: 12539281)

  • 1. [Cytocompatibility of three substituted materials of human beings' hard tissue].
    Tang Z; Chen Z
    Hua Xi Kou Qiang Yi Xue Za Zhi; 1999 Aug; 17(3):199-201. PubMed ID: 12539281
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Study on osteocompatibility of hydroxyl polycalcium sodium phosphate in vitro].
    Tang Z; Chen Z; Liu W
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2000 Jun; 17(2):122-4, 128. PubMed ID: 12557761
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [In vitro studies about the effects of implant materials on calmodulin, introcellular calcium of rat osteoblasts].
    Huang Y; Chen Z; Li P; Wu Z
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2000 Apr; 18(2):119-22. PubMed ID: 12539347
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [In vitro studies about the effects of implanted materials on osteocalcin and alkaline phosphatase of rat osteoblasts].
    Huang Y; Chen Z; Li P
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2000 Jun; 18(3):192-4. PubMed ID: 12539676
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Structural, mechanical and in vitro characterization of individually structured Ti-6Al-4V produced by direct laser forming.
    Hollander DA; von Walter M; Wirtz T; Sellei R; Schmidt-Rohlfing B; Paar O; Erli HJ
    Biomaterials; 2006 Mar; 27(7):955-63. PubMed ID: 16115681
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Novel production method and in-vitro cell compatibility of porous Ti-6Al-4V alloy disk for hard tissue engineering.
    Bhattarai SR; Khalil KA; Dewidar M; Hwang PH; Yi HK; Kim HY
    J Biomed Mater Res A; 2008 Aug; 86(2):289-99. PubMed ID: 17957720
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The role of titanium implant surface modification with hydroxyapatite nanoparticles in progressive early bone-implant fixation in vivo.
    Lin A; Wang CJ; Kelly J; Gubbi P; Nishimura I
    Int J Oral Maxillofac Implants; 2009; 24(5):808-16. PubMed ID: 19865620
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Varying Ti-6Al-4V surface roughness induces different early morphologic and molecular responses in MG63 osteoblast-like cells.
    Kim HJ; Kim SH; Kim MS; Lee EJ; Oh HG; Oh WM; Park SW; Kim WJ; Lee GJ; Choi NG; Koh JT; Dinh DB; Hardin RR; Johnson K; Sylvia VL; Schmitz JP; Dean DD
    J Biomed Mater Res A; 2005 Sep; 74(3):366-73. PubMed ID: 15983984
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Nitric acid passivation does not affect in vitro biocompatibility of titanium.
    Faria AC; Beloti MM; Rosa AL
    Int J Oral Maxillofac Implants; 2003; 18(6):820-5. PubMed ID: 14696657
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of a niobium-containing titanium alloy on osteoblast behavior in culture.
    Shapira L; Klinger A; Tadir A; Wilensky A; Halabi A
    Clin Oral Implants Res; 2009 Jun; 20(6):578-82. PubMed ID: 19530314
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Osteoblast responses to orthopedic implant materials in vitro.
    Puleo DA; Holleran LA; Doremus RH; Bizios R
    J Biomed Mater Res; 1991 Jun; 25(6):711-23. PubMed ID: 1874756
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sphene ceramics for orthopedic coating applications: an in vitro and in vivo study.
    Ramaswamy Y; Wu C; Dunstan CR; Hewson B; Eindorf T; Anderson GI; Zreiqat H
    Acta Biomater; 2009 Oct; 5(8):3192-204. PubMed ID: 19457458
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microstructure and mechanical properties of plasma sprayed HA/YSZ/Ti-6Al-4V composite coatings.
    Khor KA; Gu YW; Pan D; Cheang P
    Biomaterials; 2004 Aug; 25(18):4009-17. PubMed ID: 15046891
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Functionally graded Co-Cr-Mo coating on Ti-6Al-4V alloy structures.
    Vamsi Krishna B; Xue W; Bose S; Bandyopadhyay A
    Acta Biomater; 2008 May; 4(3):697-706. PubMed ID: 18054298
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of topographical surface modifications of electron beam melted Ti-6Al-4V titanium on human fetal osteoblasts.
    Ponader S; Vairaktaris E; Heinl P; Wilmowsky CV; Rottmair A; Körner C; Singer RF; Holst S; Schlegel KA; Neukam FW; Nkenke E
    J Biomed Mater Res A; 2008 Mar; 84(4):1111-9. PubMed ID: 17685409
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characterization of the interface in the plasma-sprayed HA coating/Ti-6Al-4V implant system.
    Filiaggi MJ; Coombs NA; Pilliar RM
    J Biomed Mater Res; 1991 Oct; 25(10):1211-29. PubMed ID: 1667401
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Modulation of the responses of human osteoblast-like cells to physiologic mechanical strains by biomaterial surfaces.
    Di Palma F; Guignandon A; Chamson A; Lafage-Proust MH; Laroche N; Peyroche S; Vico L; Rattner A
    Biomaterials; 2005 Jul; 26(20):4249-57. PubMed ID: 15683648
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of surface chemistry modification of titanium alloy on signalling pathways in human osteoblasts.
    Zreiqat H; Valenzuela SM; Nissan BB; Roest R; Knabe C; Radlanski RJ; Renz H; Evans PJ
    Biomaterials; 2005 Dec; 26(36):7579-86. PubMed ID: 16002135
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of bone-implant interface shear strength of solid hydroxyapatite and hydroxyapatite-coated titanium implants.
    Hayashi K; Inadome T; Mashima T; Sugioka Y
    J Biomed Mater Res; 1993 May; 27(5):557-63. PubMed ID: 8314808
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Novel sphene coatings on Ti-6Al-4V for orthopedic implants using sol-gel method.
    Wu C; Ramaswamy Y; Gale D; Yang W; Xiao K; Zhang L; Yin Y; Zreiqat H
    Acta Biomater; 2008 May; 4(3):569-76. PubMed ID: 18182336
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.