These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
282 related articles for article (PubMed ID: 12539939)
1. Biomechanical evaluation of fixation of clavicular fractures. Proubasta IR; Itarte JP; Cáceres EP; Llusá MP; Gil JM; Planell JA; Ginebra MP J South Orthop Assoc; 2002; 11(3):148-52. PubMed ID: 12539939 [TBL] [Abstract][Full Text] [Related]
2. Biomechanical comparison between solid and cannulated intramedullary devices for midshaft clavicle fixation. Wang SH; Lin HJ; Shen HC; Pan RY; Yang JJ BMC Musculoskelet Disord; 2019 Apr; 20(1):178. PubMed ID: 31027505 [TBL] [Abstract][Full Text] [Related]
3. Low-Profile Dual Small Plate Fixation Is Biomechanically Similar to Larger Superior or Anteroinferior Single Plate Fixation of Midshaft Clavicle Fractures. Ziegler CG; Aman ZS; Storaci HW; Finch H; Dornan GJ; Kennedy MI; Provencher MT; Hackett TR Am J Sports Med; 2019 Sep; 47(11):2678-2685. PubMed ID: 31381363 [TBL] [Abstract][Full Text] [Related]
4. Biomechanical analysis of locked and non-locked plate fixation of the clavicle. Little KJ; Riches PE; Fazzi UG Injury; 2012 Jun; 43(6):921-5. PubMed ID: 22405337 [TBL] [Abstract][Full Text] [Related]
6. Two reconstruction plates provide superior stability of displaced midshaft clavicle fractures in comparison to single plating - A biomechanical study. Yanev P; Zderic I; Pukalski Y; Enchev D; Rashkov M; Varga P; Gehweiler D; Richards G; Gueorguiev B; Baltov A Clin Biomech (Bristol); 2020 Dec; 80():105199. PubMed ID: 33129563 [TBL] [Abstract][Full Text] [Related]
7. Finite element analysis of dual small plate fixation and single plate fixation for treatment of midshaft clavicle fractures. Zhang F; Chen F; Qi Y; Qian Z; Ni S; Zhong Z; Zhang X; Li D; Yu B J Orthop Surg Res; 2020 Apr; 15(1):148. PubMed ID: 32295608 [TBL] [Abstract][Full Text] [Related]
8. Comparison between open plating versus minimally invasive plate osteosynthesis for acute displaced clavicular shaft fractures. Sohn HS; Kim WJ; Shon MS Injury; 2015 Aug; 46(8):1577-84. PubMed ID: 26077663 [TBL] [Abstract][Full Text] [Related]
9. Biomechanical aspects of locking reconstruction plate positioning in osteosynthesis of transverse clavicle fracture. Kontautas E; Pijadin A; Vilkauskas A; Domeika A Medicina (Kaunas); 2012; 48(2):80-3. PubMed ID: 22491383 [TBL] [Abstract][Full Text] [Related]
10. Biomechanical Comparison of Superior Versus Anterior Plate Position for Fixation of Distal Clavicular Fractures: A New Model. Wilkerson J; Paryavi E; Kim H; Murthi A; Pensy RA J Orthop Trauma; 2017 Jan; 31(1):e13-e17. PubMed ID: 27661732 [TBL] [Abstract][Full Text] [Related]
11. Addition of a suture anchor for coracoclavicular fixation to a superior locking plate improves stability of type IIB distal clavicle fractures. Madsen W; Yaseen Z; LaFrance R; Chen T; Awad H; Maloney M; Voloshin I Arthroscopy; 2013 Jun; 29(6):998-1004. PubMed ID: 23726106 [TBL] [Abstract][Full Text] [Related]
12. Clinical comparison of two different plating methods in minimally invasive plate osteosynthesis for clavicular midshaft fractures: A randomized controlled trial. Sohn HS; Shon MS; Lee KH; Song SJ Injury; 2015 Nov; 46(11):2230-8. PubMed ID: 26363573 [TBL] [Abstract][Full Text] [Related]
13. What Regions of the Distal Clavicle Have the Greatest Bone Mineral Density and Cortical Thickness? A Cadaveric Study. Chen RE; Soin SP; El-Shaar R; Nicandri GT; Awad HA; Maloney MD; Voloshin I Clin Orthop Relat Res; 2019 Dec; 477(12):2726-2732. PubMed ID: 31764342 [TBL] [Abstract][Full Text] [Related]
14. Bioabsorbable plating in the treatment of pediatric clavicle fractures: A biomechanical and clinical analysis. Osborn EJ; Farnsworth CL; Doan JD; Edmonds EW Clin Biomech (Bristol); 2018 Jun; 55():94-99. PubMed ID: 29727767 [TBL] [Abstract][Full Text] [Related]
15. Surgical fixation of midshaft clavicle fractures: A systematic review of biomechanical studies. Hulsmans MH; van Heijl M; Houwert RM; Burger BJ; Verleisdonk EJM; Veeger DJ; van der Meijden OA Injury; 2018 Apr; 49(4):753-765. PubMed ID: 29523350 [TBL] [Abstract][Full Text] [Related]
16. Closed reduction and internal fixation for acute midshaft clavicular fractures using cannulated screws. Chuang TY; Ho WP; Hsieh PH; Lee PC; Chen CH; Chen YJ J Trauma; 2006 Jun; 60(6):1315-20; discussion 1320-1. PubMed ID: 16766977 [TBL] [Abstract][Full Text] [Related]
17. Reduction and internal fixation for acute midshaft clavicular fractures by mini-incision using cannulated screws. Mahran MA; Elmoatasem EM; ElGebeily MA Acta Orthop Belg; 2014 Sep; 80(3):309-13. PubMed ID: 26280603 [TBL] [Abstract][Full Text] [Related]
18. Comparison of implant failure rates of different plates for midshaft clavicular fractures based on fracture classifications. Chiu YC; Huang KC; Shih CM; Lee KT; Chen KH; Hsu CE J Orthop Surg Res; 2019 Jul; 14(1):220. PubMed ID: 31311567 [TBL] [Abstract][Full Text] [Related]
19. Biomechanical evaluation of an intramedullary clavicle screw in simple oblique and butterfly wedge fractures. Kunkle BF; DesJardins JD; Campbell JR; Eichinger JK; Kissenberth MJ; Shaw KA; Tokish JM; Parada SA Proc Inst Mech Eng H; 2021 Nov; 235(11):1257-1264. PubMed ID: 34289763 [TBL] [Abstract][Full Text] [Related]
20. A surgical technique for minimally invasive plate osteosynthesis of clavicular midshaft fractures. Sohn HS; Kim BY; Shin SJ J Orthop Trauma; 2013 Apr; 27(4):e92-6. PubMed ID: 22773015 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]