137 related articles for article (PubMed ID: 12544794)
1. Complications of supramid orbital implants.
Custer PL; Lind A; Trinkaus KM
Ophthalmic Plast Reconstr Surg; 2003 Jan; 19(1):62-7. PubMed ID: 12544794
[TBL] [Abstract][Full Text] [Related]
2. Intracapsular hemorrhage rates in non-fixated nylon sheet orbital implants for orbital fracture management.
Prendes MA; Gudgel B; Kassa EB; Todd AM; Fu R; Abou-Jaoude M; Timoney PJ; Shipchandler TZ; Nunery WR; Lee HBH
Am J Otolaryngol; 2019; 40(4):509-511. PubMed ID: 30987775
[TBL] [Abstract][Full Text] [Related]
3. Nylon foil (supramid) orbital implants in pediatric orbital fracture repair.
Timoney PJ; Krakauer M; Wilkes BN; Lee HB; Nunery WR
Ophthalmic Plast Reconstr Surg; 2014; 30(3):212-4. PubMed ID: 24608327
[TBL] [Abstract][Full Text] [Related]
4. Fenestration of Solid Orbital Implants: Reducing Retrobulbar Hematoma Rate.
Farber SJ; Yu JL; Nguyen DC; Woo AS
J Craniofac Surg; 2017 Jan; 28(1):248-249. PubMed ID: 27906852
[TBL] [Abstract][Full Text] [Related]
5. Late-onset orbital hematoma secondary to alloplastic orbital implant mimicking transient ischemic attacks.
Gupta S; Aakalu VK; Ahmad AZ
Ophthalmic Plast Reconstr Surg; 2011; 27(1):e18-20. PubMed ID: 20700069
[TBL] [Abstract][Full Text] [Related]
6. Aspergillus infection of supramid orbital implant and hyperostosis of orbital bone: report of a unique case.
Mehta P; Joganathan V; Oppenheim B; Durrani OM
Orbit; 2010 Dec; 29(6):370-2. PubMed ID: 21158583
[TBL] [Abstract][Full Text] [Related]
7. Cyst formation associated with porous polyethylene orbital floor implant.
Ma'luf RN
Orbit; 2010 Dec; 29(6):343-5. PubMed ID: 21158575
[TBL] [Abstract][Full Text] [Related]
8. Smooth nylon foil (SupraFOIL) orbital implants in orbital fractures: a case series of 181 patients.
Park DJ; Garibaldi DC; Iliff NT; Grant MP; Merbs SL
Ophthalmic Plast Reconstr Surg; 2008; 24(4):266-70. PubMed ID: 18645428
[TBL] [Abstract][Full Text] [Related]
9. Orbital cysts lined with both stratified squamous and columnar epithelia: a late complication of silicone implants.
Tan CS; Ang LP; Choo CT; Cheah ES; Chee SP
Ophthalmic Plast Reconstr Surg; 2006; 22(5):398-400. PubMed ID: 16985432
[TBL] [Abstract][Full Text] [Related]
10. A case of orbital abscess following porous orbital implant infection.
Hong SW; Paik JS; Kim SY; Yang SW
Korean J Ophthalmol; 2006 Dec; 20(4):234-7. PubMed ID: 17302210
[TBL] [Abstract][Full Text] [Related]
11. Delayed complications of silicone implants used in orbital fracture repairs.
Warrier S; Prabhakaran VC; Davis G; Selva D
Orbit; 2008; 27(3):147-51. PubMed ID: 18569817
[TBL] [Abstract][Full Text] [Related]
12. Complications of orbital implants: a review of 542 patients who have undergone orbital implantation and 275 subsequent PEG placements.
Shoamanesh A; Pang NK; Oestreicher JH
Orbit; 2007 Sep; 26(3):173-82. PubMed ID: 17891645
[TBL] [Abstract][Full Text] [Related]
13. Orbital abscess that masqueraded as a retrobulbar haemorrhage.
Mohammed Saed S; Davies I; Ho MW
Br J Oral Maxillofac Surg; 2017 Apr; 55(3):334-335. PubMed ID: 27697323
[No Abstract] [Full Text] [Related]
14. Infection after insertion of alloplastic orbital floor implants.
Mauriello JA; Hargrave S; Yee S; Mostafavi R; Kapila R
Am J Ophthalmol; 1994 Feb; 117(2):246-52. PubMed ID: 8116755
[TBL] [Abstract][Full Text] [Related]
15. Complications associated with pegging hydroxyapatite orbital implants.
Jordan DR; Chan S; Mawn L; Gilberg S; Dean T; Brownstein S; Hill VE
Ophthalmology; 1999 Mar; 106(3):505-12. PubMed ID: 10080206
[TBL] [Abstract][Full Text] [Related]
16. Late migration of an orbital implant causing orbital hemorrhage with sudden proptosis and diplopia.
Rosen CE
Ophthalmic Plast Reconstr Surg; 1996 Dec; 12(4):260-2; discussion 263. PubMed ID: 8944386
[TBL] [Abstract][Full Text] [Related]
17. Long-term complications of different porous orbital implants: a 21-year review.
Lin CW; Liao SL
Br J Ophthalmol; 2017 May; 101(5):681-685. PubMed ID: 27474155
[TBL] [Abstract][Full Text] [Related]
18. Late orbital haemorrhage around alloplastic orbital floor implants: a case series and review.
Gilhotra JS; McNab AA; McKelvie P; O'Donnell BA
Clin Exp Ophthalmol; 2002 Oct; 30(5):352-5. PubMed ID: 12213160
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of computer-based volume measurement and porous polyethylene channel implants in reconstruction of large orbital wall fractures.
Ye J; Kook KH; Lee SY
Invest Ophthalmol Vis Sci; 2006 Feb; 47(2):509-13. PubMed ID: 16431943
[TBL] [Abstract][Full Text] [Related]
20. Chronic exposure of hydroxyapatite orbital implants: cilia implantation and epithelial downgrowth.
Kim JW; Kikkawa DO; Aboy A; Glasgow BJ
Ophthalmic Plast Reconstr Surg; 2000 May; 16(3):216-22. PubMed ID: 10826763
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]