BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

331 related articles for article (PubMed ID: 12546312)

  • 1. Efficiency of the glutaraldehyde test strip for monitoring the concentration of glutaraldehyde in reused solutions for disinfecting endoscopes.
    Keerasuntonpong A; Sitaposa P; Chaiprasert A; Thamlikitkul V
    J Med Assoc Thai; 2002 Nov; 85(11):1164-8. PubMed ID: 12546312
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of glutaraldehyde residues on flexible endoscopes after chemothermal treatment in an endoscope washer-disinfector.
    Dietze B; Neumann H; Mansmann U; Martiny H
    Endoscopy; 2001 Jun; 33(6):529-32. PubMed ID: 11437048
    [TBL] [Abstract][Full Text] [Related]  

  • 3. GI endoscopic reprocessing practices in the United States.
    Cheung RJ; Ortiz D; DiMarino AJ
    Gastrointest Endosc; 1999 Sep; 50(3):362-8. PubMed ID: 10462657
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Liquid disinfecting and sterilization reprocessors used for flexible endoscopes.
    Health Devices; 1994 Jun; 23(6):212-53. PubMed ID: 7852072
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee.
    BSG E
    Gut; 1998 Apr; 42(4):585-93. PubMed ID: 9616326
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Occupational exposure to glutaraldehyde during its use in chemical disinfection of endoscopes].
    Apostoli P
    Minerva Med; 2000; 91(5-6):127-32. PubMed ID: 11084848
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of electrolyzed acid water in reprocessing patient-used flexible upper endoscopes: Comparison with 2% alkaline glutaraldehyde.
    Lee JH; Rhee PL; Kim JH; Kim JJ; Paik SW; Rhee JC; Song JH; Yeom JS; Lee NY
    J Gastroenterol Hepatol; 2004 Aug; 19(8):897-903. PubMed ID: 15242493
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In-hospital evaluation of orthophthalaldehyde as a high level disinfectant for flexible endoscopes.
    Alfa MJ; Sitter DL
    J Hosp Infect; 1994 Jan; 26(1):15-26. PubMed ID: 7910179
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Synergetic germicidal effect of ultrasonic with glutaraldehyde and its application in clinical disinfection].
    Wang C; Xu X; Yu Q; Liu H
    Wei Sheng Yan Jiu; 2004 Jan; 33(1):42-4, 48. PubMed ID: 15098476
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Disinfection of endoscopes in gastroenterology. Bacteriologic evaluation of the procedure employed in the endoscopic unit at the Mongi Slim Hospital of Tunisia].
    Chenoufi Bahri B; Ben Salah N
    Ann Gastroenterol Hepatol (Paris); 1991 Dec; 27(7):309-13. PubMed ID: 1793247
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Efficacy of the disinfection of fiber endoscopes].
    Casale V; Grassi A; Ameglio F; Frasca AM
    Minerva Med; 1990; 81(1-2):75-8. PubMed ID: 2314620
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of 12-Week Shelf Life of Patient-Ready Endoscopes.
    Lacey V; Good K; Toliver C; Jenkins S; DeGuzman PB
    Gastroenterol Nurs; 2019; 42(2):159-164. PubMed ID: 30946303
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Endoscope disinfection by ortho-phthalaldehyde in a clinical setting: an evaluation of reprocessing time and costs compared with glutaraldehyde.
    Hession SM
    Gastroenterol Nurs; 2003; 26(3):110-4. PubMed ID: 12811321
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reprocessing flexible gastrointestinal endoscopes after a period of disuse: is it necessary?
    Vergis AS; Thomson D; Pieroni P; Dhalla S
    Endoscopy; 2007 Aug; 39(8):737-9. PubMed ID: 17661250
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Practical toolkit for monitoring endoscope reprocessing effectiveness: Identification of viable bacteria on gastroscopes, colonoscopes, and bronchoscopes.
    Ofstead CL; Doyle EM; Eiland JE; Amelang MR; Wetzler HP; England DM; Mascotti KM; Shaw MJ
    Am J Infect Control; 2016 Jul; 44(7):815-9. PubMed ID: 26952038
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microbial bioburden in endoscope reprocessing and an in-use evaluation of the high-level disinfection capabilities of Cidex PA.
    Vesley D; Melson J; Stanley P
    Gastroenterol Nurs; 1999; 22(2):63-8. PubMed ID: 10382415
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Microbiological monitoring of endoscopes: 5-year review.
    Gillespie EE; Kotsanas D; Stuart RL
    J Gastroenterol Hepatol; 2008 Jul; 23(7 Pt 1):1069-74. PubMed ID: 18086113
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reprocessing in digestive endoscopy units in Lombardy: results of a regional survey.
    Spinzi G; Fasoli R; Centenaro R; Minoli G;
    Dig Liver Dis; 2008 Nov; 40(11):890-6. PubMed ID: 18400569
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of a solution of super-oxidized water (Sterilox) with glutaraldehyde for the disinfection of bronchoscopes, contaminated.
    Middleton AM; Chadwick MV; Sanderson JL; Gaya H
    J Hosp Infect; 2000 Aug; 45(4):278-82. PubMed ID: 10973744
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pseudo-outbreak of Mycobacterium chelonae and Methylobacterium mesophilicum caused by contamination of an automated endoscopy washer.
    Kressel AB; Kidd F
    Infect Control Hosp Epidemiol; 2001 Jul; 22(7):414-8. PubMed ID: 11583208
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.