BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 12551676)

  • 1. Comparison of 4 methods for quantifying posterior capsule opacification.
    Findl O; Buehl W; Menapace R; Georgopoulos M; Rainer G; Siegl H; Kaider A; Pinz A
    J Cataract Refract Surg; 2003 Jan; 29(1):106-11. PubMed ID: 12551676
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Automated qualitative and quantitative assessment of posterior capsule opacification by Automated Quantification of After-Cataract II (AQUA II) system.
    Kronschläger M; Siegl H; Pinz A; Feichtenhofer C; Buehl W; Hirnschall N; Findl O
    BMC Ophthalmol; 2019 May; 19(1):114. PubMed ID: 31101021
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification.
    Buehl W; Findl O; Menapace R; Georgopoulos M; Rainer G; Wirtitsch M; Siegl H; Pinz A
    J Cataract Refract Surg; 2002 Feb; 28(2):265-70. PubMed ID: 11821208
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Association between intensity of posterior capsule opacification and visual acuity.
    Buehl W; Sacu S; Findl O
    J Cataract Refract Surg; 2005 Mar; 31(3):543-7. PubMed ID: 15811742
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Correlation between the measurement of posterior capsule opacification severity and visual function testing.
    Jose RM; Bender LE; Boyce JF; Heatley C
    J Cataract Refract Surg; 2005 Mar; 31(3):534-42. PubMed ID: 15811741
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Removing Subjective Post-Mortem Grading from Posterior Capsular Opacification: A New Automated Detector Opacification Software, ADOS.
    Mastromonaco C; Balazsi M; Zoroquiain P; Esposito E; Coblentz J; Logan P; Burnier MN
    Curr Eye Res; 2018 Nov; 43(11):1362-1368. PubMed ID: 30009642
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pentacam tomograms: a novel method for quantification of posterior capsule opacification.
    Grewal D; Jain R; Brar GS; Grewal SP
    Invest Ophthalmol Vis Sci; 2008 May; 49(5):2004-8. PubMed ID: 18436833
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quantification of posterior capsular opacification in digital images after cataract surgery.
    Barman SA; Hollick EJ; Boyce JF; Spalton DJ; Uyyanonvara B; Sanguinetti G; Meacock W
    Invest Ophthalmol Vis Sci; 2000 Nov; 41(12):3882-92. PubMed ID: 11053290
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of posterior capsule opacification after two different surgical methods of cataract extraction.
    Nekolová J; Pozlerová J; Jirásková N; Rozsíval P; Kadlecová J
    Am J Ophthalmol; 2008 Mar; 145(3):493-498. PubMed ID: 18201683
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of anterior capsule polishing on posterior capsule opacification and neodymium:YAG capsulotomy rates: three-year randomized trial.
    Menapace R; Wirtitsch M; Findl O; Buehl W; Kriechbaum K; Sacu S
    J Cataract Refract Surg; 2005 Nov; 31(11):2067-75. PubMed ID: 16412917
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification.
    Buehl W; Findl O; Menapace R; Sacu S; Kriechbaum K; Koeppl C; Wirtitsch M
    J Cataract Refract Surg; 2005 May; 31(5):954-61. PubMed ID: 15975461
    [TBL] [Abstract][Full Text] [Related]  

  • 12. POCOman: new system for quantifying posterior capsule opacification.
    Bender L; Spalton DJ; Uyanonvara B; Boyce J; Heatley C; Jose R; Khan J
    J Cataract Refract Surg; 2004 Oct; 30(10):2058-63. PubMed ID: 15474814
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of a silicone intraocular lens with a sharp posterior optic edge on posterior capsule opacification.
    Buehl W; Menapace R; Sacu S; Kriechbaum K; Koeppl C; Wirtitsch M; Georgopoulos M; Findl O
    J Cataract Refract Surg; 2004 Aug; 30(8):1661-7. PubMed ID: 15313288
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Removal of reflections in the photographic assessment of PCO by fusion of digital retroillumination images.
    Findl O; Buehl W; Siegl H; Pinz A
    Invest Ophthalmol Vis Sci; 2003 Jan; 44(1):275-80. PubMed ID: 12506085
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Digital image capture and automated analysis of posterior capsular opacification.
    Friedman DS; Duncan DD; Munoz B; West SK; Schein OD
    Invest Ophthalmol Vis Sci; 1999 Jul; 40(8):1715-26. PubMed ID: 10393041
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Long-term effect of optic edge design in a silicone intraocular lens on posterior capsule opacification.
    Buehl W; Menapace R; Findl O; Neumayer T; Bolz M; Prinz A
    Am J Ophthalmol; 2007 Jun; 143(6):913-919. PubMed ID: 17399674
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retroillumination versus reflected-light images in the photographic assessment of posterior capsule opacification.
    Camparini M; Macaluso C; Reggiani L; Maraini G
    Invest Ophthalmol Vis Sci; 2000 Sep; 41(10):3074-9. PubMed ID: 10967066
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Posterior capsule opacification and neodymium:YAG laser capsulotomy rates with a round-edged silicone and a sharp-edged hydrophobic acrylic intraocular lens 10 years after surgery.
    Vock L; Menapace R; Stifter E; Georgopoulos M; Sacu S; Bühl W
    J Cataract Refract Surg; 2009 Mar; 35(3):459-65. PubMed ID: 19251138
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A freely accessible, evidence based, objective system of analysis of posterior capsular opacification; evidence for its validity and reliability.
    Aslam TM; Patton N; Graham J
    BMC Ophthalmol; 2005 Apr; 5():9. PubMed ID: 15817125
    [TBL] [Abstract][Full Text] [Related]  

  • 20. OSCA: a comprehensive open-access system of analysis of posterior capsular opacification.
    Aslam TM; Patton N; Rose CJ
    BMC Ophthalmol; 2006 Aug; 6():30. PubMed ID: 16875500
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.