These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 12552752)

  • 21. Resonator with reduced sample heating and increased homogeneity for solid-state NMR.
    Krahn A; Priller U; Emsley L; Engelke F
    J Magn Reson; 2008 Mar; 191(1):78-92. PubMed ID: 18187352
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The design of a ferrofluid magnetic pipette.
    Greivell NE; Hannaford B
    IEEE Trans Biomed Eng; 1997 Mar; 44(3):129-35. PubMed ID: 9216126
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A variable pulse-burst electromagnetic generator for electrical stimulation of biological systems.
    Reddy GN; Saha S
    J Biomed Eng; 1983 Oct; 5(4):336-9. PubMed ID: 6632846
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Mean-square error due to gradiometer field measuring devices.
    Hatsell CP
    IEEE Trans Biomed Eng; 1991 Jun; 38(6):597-601. PubMed ID: 1879849
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A device for generation of electromagnetic fields of extremely low frequency.
    Wahlström O; Knutsson H
    J Biomed Eng; 1984 Oct; 6(4):293-6. PubMed ID: 6503256
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Improved electromagnetic velocity drive for Mössbauer experiments.
    Genand-Riondet N; Imbert P; Lericque JF
    Rev Sci Instrum; 1978 May; 49(5):606. PubMed ID: 18699157
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Magnetic Effects on Electrolyte Solutions in Pulse and Alternating Fields.
    Oshitani J; Uehara R; Higashitani K
    J Colloid Interface Sci; 1999 Jan; 209(2):374-379. PubMed ID: 9885265
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Ophthalmological hand-operated electromagnetic device EMGR-02].
    Semiusov GG
    Med Tekh; 1990; (2):47-8. PubMed ID: 2377074
    [No Abstract]   [Full Text] [Related]  

  • 29. A newly designed and constructed 20 kHz magnetic field exposure facility for in vivo study.
    Shigemitsu T; Negishi T; Yamazaki K; Kawahara Y; Haga A; Kobayashi K; Muramatsu K
    Bioelectromagnetics; 2009 Jan; 30(1):36-44. PubMed ID: 18671234
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Use of an electromagnetic eye movement monitor for easy measurement of arm movements.
    Remmel RS
    IEEE Trans Biomed Eng; 2006 Nov; 53(11):2356-61. PubMed ID: 17073342
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A patch antenna design for application in a phased-array head and neck hyperthermia applicator.
    Paulides MM; Bakker JF; Chavannes N; Van Rhoon GC
    IEEE Trans Biomed Eng; 2007 Nov; 54(11):2057-63. PubMed ID: 18018701
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A real electro-magnetic placebo (REMP) device for sham transcranial magnetic stimulation (TMS).
    Rossi S; Ferro M; Cincotta M; Ulivelli M; Bartalini S; Miniussi C; Giovannelli F; Passero S
    Clin Neurophysiol; 2007 Mar; 118(3):709-16. PubMed ID: 17188568
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Method for calibrating a Rogowski coil of fast time response.
    Liu R; Wang X; Zou X; Yuan J; Zou N; He L
    Rev Sci Instrum; 2007 Aug; 78(8):084702. PubMed ID: 17764342
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Design of a magnetic field generator for experiments on magnetic effects in cell cultures.
    Kinouchi Y; Ushita T; Sato K; Miyamoto H; Yamaguchi H; Yoshida Y
    Bioelectromagnetics; 1984; 5(4):399-410. PubMed ID: 6517959
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Assessment of the efficacy and safety of low frequency, low intensity magnetic fields in patients after knee endoprosthesis plasty. Part 1: in vitro safety.
    Błaszczak E; Franek A; Taradaj J; Widuchowski J; Klimczak J
    Bioelectromagnetics; 2009 Feb; 30(2):159-62. PubMed ID: 19009533
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Measuring tooth mobility with a no-contact vibration device.
    Yamane M; Yamaoka M; Hayashi M; Furutoyo I; Komori N; Ogiso B
    J Periodontal Res; 2008 Feb; 43(1):84-9. PubMed ID: 18230109
    [TBL] [Abstract][Full Text] [Related]  

  • 37. ac Modeling and impedance spectrum tests of the superconducting magnetic field coils for the Wendelstein 7-X fusion experiment.
    Ehmler H; Köppen M
    Rev Sci Instrum; 2007 Oct; 78(10):104705. PubMed ID: 17979447
    [TBL] [Abstract][Full Text] [Related]  

  • 38. An object-oriented designed finite-difference time-domain simulator for electromagnetic analysis and design in MRI--applications to high field analyses.
    Wei Q; Liu F; Xia L; Crozier S
    J Magn Reson; 2005 Feb; 172(2):222-30. PubMed ID: 15649749
    [TBL] [Abstract][Full Text] [Related]  

  • 39. An increase in cAMP concentration in mouse hippocampal slices exposed to low-frequency and pulsed magnetic fields.
    Hogan MV; Wieraszko A
    Neurosci Lett; 2004 Aug; 366(1):43-7. PubMed ID: 15265587
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Noise performance of a precision pulsed electromagnet power supply for magnetic resonance imaging.
    Matter NI; Chronik B; Pauly JM; Macovski A; Conolly SM; Scott GC
    IEEE Trans Med Imaging; 2008 Jan; 27(1):75-86. PubMed ID: 18270064
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.