27. Rapid volume flow rate estimation using transverse colour Doppler imaging. Picot PA; Fruitman M; Rankin RN; Fenster A Ultrasound Med Biol; 1995; 21(9):1199-209. PubMed ID: 8849834 [TBL] [Abstract][Full Text] [Related]
28. Vascular flow and perfusion imaging with ultrasound contrast agents. Bruce M; Averkiou M; Tiemann K; Lohmaier S; Powers J; Beach K Ultrasound Med Biol; 2004 Jun; 30(6):735-43. PubMed ID: 15219953 [TBL] [Abstract][Full Text] [Related]
29. Curvature affects Doppler investigation of vessels: implications for clinical practice. Balbis S; Roatta S; Guiot C Ultrasound Med Biol; 2005 Jan; 31(1):65-77. PubMed ID: 15653232 [TBL] [Abstract][Full Text] [Related]
30. Velocity fluctuation reduction in vector Doppler ultrasound using a hybrid single/dual-beam algorithm. Steel R; Fish PJ; Ramnarine KV; Criton A; Routh HF; Hoskins PR IEEE Trans Ultrason Ferroelectr Freq Control; 2003 Jan; 50(1):89-93. PubMed ID: 12578140 [TBL] [Abstract][Full Text] [Related]
31. Effects of nonuniform insonation by catheter-tipped Doppler transducers on velocity estimation. Moraes R; Evans DH Ultrasound Med Biol; 1995; 21(6):779-91. PubMed ID: 8571466 [TBL] [Abstract][Full Text] [Related]
32. Defining the limitations of measurements from Doppler spectral recordings. Bascom PA; Johnston KW; Cobbold RS; Ojha M J Vasc Surg; 1996 Jul; 24(1):34-44; discussion 44-5. PubMed ID: 8691525 [TBL] [Abstract][Full Text] [Related]
33. The wall signal removal in Doppler ultrasound systems based on recursive PCA. Tao Q; Wang Y; Fish P; Wang W; Cardoso J Ultrasound Med Biol; 2004 Mar; 30(3):369-79. PubMed ID: 15063519 [TBL] [Abstract][Full Text] [Related]
34. Differences in the power structures of Fourier transform and autoregressive spectral estimates of narrow-band Doppler signals. Fan L; Evans DH IEEE Trans Biomed Eng; 1994 Apr; 41(4):387-90. PubMed ID: 8063305 [TBL] [Abstract][Full Text] [Related]
35. Demonstration of three-dimensional vector flow estimation using bandwidth and two transducers on a flow phantom. McArdle A; Newhouse VL; Beach KW Ultrasound Med Biol; 1995; 21(5):679-92. PubMed ID: 8525558 [TBL] [Abstract][Full Text] [Related]
36. Sources of error in maximum velocity estimation using linear phased-array Doppler systems with steady flow. Steinman AH; Tavakkoli J; Myers JG; Cobbold RS; Johnston KW Ultrasound Med Biol; 2001 May; 27(5):655-64. PubMed ID: 11397530 [TBL] [Abstract][Full Text] [Related]
37. Algorithm of the noninvasive diagnosis method on the atherosclerosis by ultrasonic Doppler effect. Yokobori AT; Ohkuma T; Sasaki S; Yoshinari H; Yokobori T; Ohuchi H; Mori S Biomed Mater Eng; 1994; 4(2):87-96. PubMed ID: 7920201 [TBL] [Abstract][Full Text] [Related]
38. A new method for blood velocity measurements using ultrasound FMCW signals. Kunita M; Sudo M; Inoue S; Akahane M IEEE Trans Ultrason Ferroelectr Freq Control; 2010 May; 57(5):1064-76. PubMed ID: 20442017 [TBL] [Abstract][Full Text] [Related]
39. [Causes and influential factors of spectral broadening in Doppler flow signal]. Wen Y; Qian M; Gong X; Zhen B; Wan M Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 1997 Jun; 14(2):118-23. PubMed ID: 9817638 [TBL] [Abstract][Full Text] [Related]
40. Ultrasonic estimation of tissue perfusion: a stochastic approach. Adler RS; Rubin JM; Fowlkes JB; Carson PL; Pallister JE Ultrasound Med Biol; 1995; 21(4):493-500. PubMed ID: 7571142 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]