BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 12553519)

  • 1. The dynamic volume changes of polymerising polymethyl methacrylate bone cement.
    Muller SD; Green SM; McCaskie AW
    Acta Orthop Scand; 2002 Dec; 73(6):684-7. PubMed ID: 12553519
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Porosity reduction in bone cement at the cement-stem interface.
    Bishop NE; Ferguson S; Tepic S
    J Bone Joint Surg Br; 1996 May; 78(3):349-56. PubMed ID: 8636165
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of mixing on gentamicin release from polymethylmethacrylate bone cements.
    Neut D; van de Belt H; van Horn JR; van der Mei HC; Busscher HJ
    Acta Orthop Scand; 2003 Dec; 74(6):670-6. PubMed ID: 14763697
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vivo behavior of acrylic bone cement in total hip arthroplasty.
    Ries MD; Young E; Al-Marashi L; Goldstein P; Hetherington A; Petrie T; Pruitt L
    Biomaterials; 2006 Jan; 27(2):256-61. PubMed ID: 16039712
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Vacuum mixing systems for bone cement completion - comparison of different systems].
    Horas U; Seidel P; Heiss C; Kilian O; Dingeldein E; Schnettler R
    Z Orthop Ihre Grenzgeb; 2002; 140(6):603-10. PubMed ID: 12476381
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Examination of rotational fixation of the femoral component in total hip arthroplasty. A mechanical study of micromovement and acoustic emission.
    Sugiyama H; Whiteside LA; Kaiser AD
    Clin Orthop Relat Res; 1989 Dec; (249):122-8. PubMed ID: 2582663
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of vacuum mixing and pre-heating the femoral component on the mechanical properties of the cement mantle.
    Baleani M; Bialoblocka-Juszczyk E; Engels GE; Viceconti M
    J Bone Joint Surg Br; 2010 Mar; 92(3):454-60. PubMed ID: 20190321
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [A quantitative analysis for determining porosity of pre-compressed and vacuum-mixed bone cement].
    Hahn M; Engelbrecht E; Delling G
    Chirurg; 1990 Jul; 61(7):512-7. PubMed ID: 2394193
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of various vacuum mixing systems and bone cements as regards reliability, porosity and bending strength.
    Mau H; Schelling K; Heisel C; Wang JS; Breusch SJ
    Acta Orthop Scand; 2004 Apr; 75(2):160-72. PubMed ID: 15180231
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of pulsed jet lavage in vertebroplasty on injection forces of polymethylmethacrylate bone cement, material distribution, and potential fat embolism: a cadaver study.
    Benneker LM; Heini PF; Suhm N; Gisep A
    Spine (Phila Pa 1976); 2008 Nov; 33(23):E906-10. PubMed ID: 18978585
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of temperature and vacuum mixing on bone cement properties.
    Smeds S; Goertzen D; Ivarsson I
    Clin Orthop Relat Res; 1997 Jan; (334):326-34. PubMed ID: 9005930
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Mechanical properties of new low viscosity bone cements--can be improved by vacuum mixing].
    Kaltenkirchen N; Fritsch E; Rupp S; Kraus P
    Unfallchirurg; 1996 Jul; 99(7):492-7. PubMed ID: 8928019
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [New PMMA bone cements for vacuum mixing systems].
    Schelling K; Heisel C; Schnürer SM; Mau H; Breusch SJ
    Orthopade; 2002 Jun; 31(6):556-62. PubMed ID: 12149927
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Vacuum-mixing cement does not decrease overall porosity in cemented femoral stems: an in vitro laboratory investigation.
    Messick KJ; Miller MA; Damron LA; Race A; Clarke MT; Mann KA
    J Bone Joint Surg Br; 2007 Aug; 89(8):1115-21. PubMed ID: 17785755
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Do we need to vacuum mix or centrifuge cement?
    Wixson RL
    Clin Orthop Relat Res; 1992 Dec; (285):84-90. PubMed ID: 1446459
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The use of handheld cement sample as a guide to the setting of in situ cement mantle.
    Eni-Olotu DO; Nokes L; Rassoulian H; Goddard JR
    J Arthroplasty; 2001 Apr; 16(3):376-8. PubMed ID: 11307137
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Variation of the mechanical properties of PMMA to suit osteoporotic cancellous bone.
    Boger A; Bisig A; Bohner M; Heini P; Schneider E
    J Biomater Sci Polym Ed; 2008; 19(9):1125-42. PubMed ID: 18727856
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Why would cement porosity reduction be clinically irrelevant, while experimental data show the contrary.
    Janssen D; Stolk J; Verdonschot N
    J Orthop Res; 2005 Jul; 23(4):691-7. PubMed ID: 16022978
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Creep characteristics of hand- and vacuum-mixed acrylic bone cement at elevated stress levels.
    Norman TL; Kish V; Blaha JD; Gruen TA; Hustosky K
    J Biomed Mater Res; 1995 Apr; 29(4):495-501. PubMed ID: 7622534
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Damage accumulation, fatigue and creep behaviour of vacuum mixed bone cement.
    Jeffers JR; Browne M; Taylor M
    Biomaterials; 2005 Sep; 26(27):5532-41. PubMed ID: 15860209
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.